HYDAC · Betamicron 4 R · return line

0240 R 010 BN4HC filter element: specifications & equivalents

The 0240 R 010 BN4HC is a HYDAC return-line hydraulic filter element, built with betamicron 4 microglass (bn4hc) media, sized 74 × 204 mm OD × length (ID 34 mm), rated at 10 µm class (β12(c) ≥ 1000 per ISO 16889 (10 µm at β ≥ 200)). Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 74 × 204 mm
Inside diameter 34 mm
Filtration rating 10 µm nom.
Beta rating β 12(c) ≥ 1000 per ISO 16889 (10 µm at β ≥ 200)
Media Betamicron 4 microglass (BN4HC)
Collapse / burst 20 bar
Line type return
Partially verified. Fit and grade trace to an official interchange document; dimensional values are compiled from 2 aftermarket listing(s) and must be confirmed against the manufacturer housing drawing. Confidence score 0.85.

Dimensions and weight are compiled from two independent aftermarket listings; confirm against the HYDAC housing drawing before ordering.

Specification table

ParameterValue
Filter type return line
Media Betamicron 4 microglass (BN4HC)
Filtration rating 10 µm
Rating basis nominal
Beta ratio β12(c) ≥ 1000 per ISO 16889 (10 µm at β ≥ 200)
Outside diameter OD 74 mm
Inside diameter ID 34 mm
Length 204 mm
Nominal length code 6 in
Flow direction outside-in
Collapse / burst pressure 20 bar
Integral bypass valve none (housing/valve-dependent)
Seal material Nitrile (NBR)
Operating temperature -30 to 100 °C
Mass 600 g
Source catalog Pall Corporation: Red1000 Series Filter Element Interchange List (M&EREDCOMPEN (Pall literature library))
HYDAC / Airline Hydraulics: Betamicron Filter Elements
BAMA Filtration (filtersfilter.com): Replacement HYDAC hydraulic return filter 0240R010BN4HC
Heboke / Gu’an Fangte Filter (made-in-china.com): 0240R010BN4HC replacement element
Last verified2026-09-27

Sources: Pall Corporation — Red1000 Series Filter Element Interchange List · HYDAC / Airline Hydraulics — Betamicron Filter Elements · BAMA Filtration (filtersfilter.com) — Replacement HYDAC hydraulic return filter 0240R010BN4HC · Heboke / Gu’an Fangte Filter (made-in-china.com) — 0240R010BN4HC replacement element — accessed 2026-09-26.

HYDAC® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized HYDAC distributor.

Dimensions & series range

Outside diameter74 mm (2.913 in)
Inside diameter34 mm (1.339 in)
Overall length204 mm (8.031 in)
Nominal length code6 inches

All 74×204 mm interchange elements →

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ HC2218FCS6HPallfullDirect fit per Pall’s Red1000 interchange list (no adaptor). Grades print differently — HYDAC 010 code vs Pall 12 µm β>1000 — the two conventions describe the same multipass-tested grade; verify cleanliness targets for critical drives. For housings using the reusable bypass valve.
↔ HC2226FCS6H50PallpartialSame envelope and 12 µm β>1000 grade, but this Red1000 execution has an integral 3.4 bar (50 psid) bypass valve; the plain execution leaves bypass control to the housing valve. Match the existing valve strategy before substituting.
↔ 14470812
page in verification queue
UFIverifyUFI hydraulic element number quoted in the aftermarket table; confirmation pending.
↔ 938279Q
page in verification queue
AftermarketverifyParker return-line cartridge quoted in aftermarket interchange lists; verify end-cap and bypass configuration.
↔ DC240CA10ANP
page in verification queue
MP FiltriverifyMP Filtri DC-series element for 0240-size return housings; verify seal and valve options.
↔ HC2226FKS6H
page in verification queue
conflict
PallverifyQuoted by aftermarket source (s4) but Pall’s official list prints HC2226FCS6H50 for this position — grade/configuration conflict; confirm before ordering.
↔ HD829
page in verification queue
MANN-FILTERverifyMANN-FILTER industrial element quoted against 0240R010BN4HC; verify micron rating convention.
↔ HF6889
page in verification queue
FleetguardverifyFleetguard HF-series hydraulic cartridge quoted for the 0240 R envelope; verify before fleet substitution.
↔ P170617
page in verification queue
DonaldsonverifyAftermarket table quotes this Donaldson cartridge; envelope and micron not yet catalog-verified.
↔ P566979
page in verification queue
DonaldsonverifySecond Donaldson number in the same aftermarket row; confirm which execution matches the RF housing.
↔ PR3292
page in verification queue
ParkerverifyParker PR-series number quoted alongside 938279Q; catalog confirmation pending.
↔ R84E10GV
page in verification queue
WIXverifyWIX industrial return-filter cartridge; aftermarket-quoted only.
↔ RE-070-G-10-BSTAUFFverifySTAUFF RE-series replacement element per aftermarket table; check grade-code equivalence (10 µm class).

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the 0240 R 010 BN4HC model number is decoded

  • 0240Element size code for the HYDAC RF/RFM return-filter housing family (0240 size).
  • RReturn-line element (installed in a tank-top return filter).
  • 010Filtration grade code: 10 µm class (12 µm(c) at β ≥ 1000 per the ISO 16889 multipass convention used in Pall’s interchange list).
  • BN4HCBetamicron 4 microglass media, low-collapse execution (~20 bar collapse pressure) with nitrile seals; BH4HC is the 210 bar high-collapse variant.

Typical equipment & applications

  • Tank-mounted return-line hydraulic filters
  • Hydraulic power units and lubrication systems
  • Construction and agricultural machinery
  • Machine tool and industrial hydraulic systems

Selection pitfalls — read before you substitute

  • A return-line element is not a pressure-line element: return cartridges (BN4HC low-collapse) tolerate roughly 20 bar differential, while BH4HC pressure executions are rated to 210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
  • This element has no integral bypass — opening pressure is set by the housing’s reusable bypass valve. Confirm the valve setting (commonly 3.4 bar) is present before fitting.
  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the 0240 R 010 BN4HC filter element?
The published envelope is 74 mm OD × 204 mm length with a 34 mm inside diameter (2.913 × 8.031 in × 1.339 in ID). Confirm against the housing drawing before ordering.
What micron rating does 0240 R 010 BN4HC use?
This element is rated 10 µm (nominal class) — β12(c) ≥ 1000 per ISO 16889 (10 µm at β ≥ 200). Always compare Beta ratings at the same test point: two brands may print different micron numbers for the same physical grade.
What replaces the 0240 R 010 BN4HC filter element?
1 catalog-confirmed full match(es) (HC2218FCS6H); 1 partial match(es) requiring parameter review; 11 aftermarket-quoted number(s) pending catalog verification
How do I read the 0240 R 010 BN4HC part number?
See the designation decoder above: each segment of 0240R010BN4HC encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Same-envelope elements from other brands

View full interchange →

These 3 catalog element(s) share the 74×204 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.

Other models in the Betamicron 4 R series

All 52 →

Reviewed & verified by the ElementRef engineering desk against Pall Corporation and HYDAC / Airline Hydraulics and BAMA Filtration (filtersfilter.com) and Heboke / Gu’an Fangte Filter (made-in-china.com) on 2026-09-27. Read our editorial & correction policy.