Pall · Red1000 · return line
HC2218FCS6H filter element: specifications & equivalents
The HC2218FCS6H is a Pall return-line hydraulic filter element, built with red1000 with coralan srt (stress-resistant media technology) media, sized 74 × 204 mm OD × length (ID 34 mm), rated at 12 µm absolute (β12(c) > 1000 per ISO 16889). Verify against the current manufacturer data sheet before ordering.
Dimensions inferred from Pall’s direct-fit statement for the HYDAC 0240 R envelope and aftermarket measurements of that envelope; verify against the Pall data sheet.
Specification table
| Parameter | Value |
|---|---|
| Filter type | return line |
| Media | Red1000 with Coralan SRT (stress-resistant media technology) |
| Filtration rating | 12 µm |
| Rating basis | absolute |
| Beta ratio | β12(c) > 1000 per ISO 16889 |
| Outside diameter OD | 74 mm |
| Inside diameter ID | 34 mm |
| Length | 204 mm |
| Nominal length code | 6 in |
| Flow direction | outside-in |
| Collapse / burst pressure | 10 bar |
| Integral bypass valve | none (housing/valve-dependent) |
| Source catalog | Pall Corporation: Red1000 Series Filter Element Interchange List (M&EREDCOMPEN (Pall literature library)) Heboke / Gu’an Fangte Filter (made-in-china.com): 0240R010BN4HC replacement element |
| Last verified | 2026-09-27 |
Sources: Pall Corporation — Red1000 Series Filter Element Interchange List · Heboke / Gu’an Fangte Filter (made-in-china.com) — 0240R010BN4HC replacement element — accessed 2026-09-26.
Pall® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Pall distributor.
Dimensions & series range
| Outside diameter | 74 mm (2.913 in) |
| Inside diameter | 34 mm (1.339 in) |
| Overall length | 204 mm (8.031 in) |
| Nominal length code | 6 inches |
All 74×204 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
| ↔ 0240 R 010 BN4HC | HYDAC | full | Direct fit per Pall’s Red1000 interchange list (no adaptor). Grades print differently — HYDAC 010 code vs Pall 12 µm β>1000 — the two conventions describe the same multipass-tested grade; verify cleanliness targets for critical drives. For housings using the reusable bypass valve. |
| ↔ RE-070-G-10-B | STAUFF | partial | STAUFF Filter Interchange lists HC 2218 FCS 6H (PALL) as replaced by RE-070-G-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the HC2218FCS6H model number is decoded
- HCPall hydraulic cartridge element platform.
- 2218Housing envelope / configuration block — this execution fits HYDAC 0160/0240 return-filter housings per Pall’s interchange list.
- FCRed1000 (Coralan SRT media) element configuration code.
- SMedia grade: 12 µm at βx(c) > 1000 per ISO 16889. P=5, N=7, S=12, T=22 µm.
- 6Nominal element length: 6 inches.
- HSeal / end-cap execution for the matched HYDAC housing; verify seal compound in the Pall data sheet for the fluid medium.
Typical equipment & applications
- Tank-mounted return-line hydraulic filters
- Hydraulic power units and lubrication systems
- Construction and agricultural machinery
- Machine tool and industrial hydraulic systems
Selection pitfalls — read before you substitute
- A return-line element is not a pressure-line element: return cartridges (BN4HC low-collapse) tolerate roughly 20 bar differential, while BH4HC pressure executions are rated to 210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
- This element has no integral bypass — opening pressure is set by the housing’s reusable bypass valve. Confirm the valve setting (commonly 3.4 bar) is present before fitting.
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What are the dimensions of the HC2218FCS6H filter element?
What micron rating does HC2218FCS6H use?
What replaces the HC2218FCS6H filter element?
How do I read the HC2218FCS6H part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Same-envelope elements from other brands
View full interchange →These 3 catalog element(s) share the 74×204 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.
Other models in the Red1000 series
All 36 →Reviewed & verified by the ElementRef engineering desk against Pall Corporation and Heboke / Gu’an Fangte Filter (made-in-china.com) on 2026-09-27. Read our editorial & correction policy.