Pall · Red1000 · return line
HC2226FCS6H50 filter element: specifications & equivalents
The HC2226FCS6H50 is a Pall return-line hydraulic filter element, built with red1000 with coralan srt (stress-resistant media technology) media, sized 74 × 204 mm OD × length (ID 34 mm), rated at 12 µm absolute (β12(c) > 1000 per ISO 16889). Verify against the current manufacturer data sheet before ordering.
Dimensions inferred from Pall’s direct-fit statement for the HYDAC 0240 R envelope and aftermarket measurements of that envelope; verify against the Pall data sheet.
Specification table
| Parameter | Value |
|---|---|
| Filter type | return line |
| Media | Red1000 with Coralan SRT (stress-resistant media technology) |
| Filtration rating | 12 µm |
| Rating basis | absolute |
| Beta ratio | β12(c) > 1000 per ISO 16889 |
| Outside diameter OD | 74 mm |
| Inside diameter ID | 34 mm |
| Length | 204 mm |
| Nominal length code | 6 in |
| Flow direction | outside-in |
| Collapse / burst pressure | 10 bar |
| Integral bypass valve | opens at 3.4 bar |
| Source catalog | Pall Corporation: Red1000 Series Filter Element Interchange List (M&EREDCOMPEN (Pall literature library)) Heboke / Gu’an Fangte Filter (made-in-china.com): 0240R010BN4HC replacement element |
| Last verified | 2026-09-27 |
Sources: Pall Corporation — Red1000 Series Filter Element Interchange List · Heboke / Gu’an Fangte Filter (made-in-china.com) — 0240R010BN4HC replacement element — accessed 2026-09-26.
Pall® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Pall distributor.
Dimensions & series range
| Outside diameter | 74 mm (2.913 in) |
| Inside diameter | 34 mm (1.339 in) |
| Overall length | 204 mm (8.031 in) |
| Nominal length code | 6 inches |
All 74×204 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
| ↔ 0240 R 010 BN4HC | HYDAC | partial | Same envelope and 12 µm β>1000 grade, but this Red1000 execution has an integral 3.4 bar (50 psid) bypass valve; the plain execution leaves bypass control to the housing valve. Match the existing valve strategy before substituting. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the HC2226FCS6H50 model number is decoded
- HCPall hydraulic cartridge element platform.
- 2226Housing envelope / configuration block — this execution fits HYDAC 0240 (integral bypass) return-filter housings per Pall’s interchange list.
- FCRed1000 (Coralan SRT media) element configuration code.
- SMedia grade: 12 µm at βx(c) > 1000 per ISO 16889. P=5, N=7, S=12, T=22 µm.
- 6Nominal element length: 6 inches.
- H50Integral bypass-valve execution, opens at 3.4 bar (50 psid). Without “50”, the element is for housings using the reusable bypass valve.
Typical equipment & applications
- Tank-mounted return-line hydraulic filters
- Hydraulic power units and lubrication systems
- Construction and agricultural machinery
- Machine tool and industrial hydraulic systems
Selection pitfalls — read before you substitute
- A return-line element is not a pressure-line element: return cartridges (BN4HC low-collapse) tolerate roughly 20 bar differential, while BH4HC pressure executions are rated to 210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
- This execution carries an integral bypass valve (opens at 3.4 bar). The same envelope also exists without it, relying on the housing valve. Mixing the two strategies changes cold-start protection — match what was installed originally.
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What are the dimensions of the HC2226FCS6H50 filter element?
What micron rating does HC2226FCS6H50 use?
What replaces the HC2226FCS6H50 filter element?
How do I read the HC2226FCS6H50 part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Same-envelope elements from other brands
View full interchange →These 3 catalog element(s) share the 74×204 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.
Other models in the Red1000 series
All 36 →Reviewed & verified by the ElementRef engineering desk against Pall Corporation and Heboke / Gu’an Fangte Filter (made-in-china.com) on 2026-09-27. Read our editorial & correction policy.