WIX Filters · 57xxx · return line

57522 filter element: specifications & equivalents

The 57522 is a WIX Filters return-line hydraulic filter element, built with glass media, sized 78 × 210 mm OD × length (ID 43 mm), rated at 10 µm class (β10 = 200). Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 78 × 210 mm
Inside diameter 43 mm
Filtration rating 10 µm nom.
Beta rating β 10 = 200
Media Glass
Line type return
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-28. Confidence score 0.90.

Specification table

ParameterValue
Filter type return line
Media Glass
Filtration rating 10 µm
Rating basis nominal
Beta ratio β10 = 200
Outside diameter OD 78 mm
Inside diameter ID 43 mm
Length 210 mm
End caps open-ended cartridge element (no baseplate)
Flow direction outside-in
Integral bypass valve none (housing/valve-dependent)
Seal material Nitrile (NBR)
Manufacturer part no. 57522
Source catalog WIX Filters (MANN+HUMMEL): WIX Filters online product catalog
Last verified2026-09-28

Sources: WIX Filters (MANN+HUMMEL) — WIX Filters online product catalog — accessed 2026-09-26.

WIX Filters® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized WIX Filters distributor.

Dimensional drawing

57522 — FILTER ELEMENTWIX Filters · 57xxx · return line · dimensional reference drawingFRONT VIEWTOP VIEW210 mmØ78 mmØ78Ø43 boreTECHNICAL DATAElement typereturn lineMediaGlassRating10 µm nominalBeta ratioβ10 = 200SealNitrile (NBR)Outside dia. OD78 mmInside dia. ID43 mmLength210 mmEnd capsopen-ended cartridge element (no baseplate)WIX Filters (MANN+HUMMEL) — WIX Filters online product catalog, accessed 2026-09-26NOTES1. Dimensions in millimetres, nominal values as cited in the source line above; manufacturing tolerances and interface details per the manufacturer data sheet.2. Schematic section derived from catalog data — not a manufacturer drawing. Confirm thread, end caps, seal compound and micron/Beta grade against the original element before ordering.3. ElementRef is an independent reference database; not affiliated with, authorised or endorsed by WIX Filters.ELEMENTREF · 57522DWG NO.ER-57522-DWG-01DATA DATE2026-09-28SCALE1:1.2REV.A
Reference drawing generated from the source values cited on this page — nominal envelope, schematic section, not a manufacturer drawing. The PDF is A3 landscape and vector; the PNG is sized for a WhatsApp preview. Confirm thread, end caps, seal compound and micron/Beta grade against the original element before ordering.

Dimensions & series range

Outside diameter78 mm (3.071 in)
Inside diameter43 mm (1.693 in)
Overall length210 mm (8.268 in)

All 78×210 mm interchange elements →

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ D141G10BFiltrecpartialFiltrec's official Cross Navigator maps WIX 57522 to FILTREC D141G10B as a direct replacement, publishing the FILTREC element's OD/ID/height envelope and media grade. Rated micron differs (10 vs 12 µm) — verify efficiency class and collapse/seal for the housing before substituting.
↔ HF30396FleetguardpartialFleetguard's online catalog lists 57522 as an interchange for HF30396. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

Full chart: WIX Filters cross reference chart →

How the 57522 model number is decoded

  • 57522WIX hydraulic cartridge element part number.
  • 78 mm OD / 43 mm IDCartridge envelope (outside/inside diameter); no mounting thread.
  • GlassFilter media: Glass.

Typical equipment & applications

  • Mobile and industrial hydraulic return circuits
  • Construction and agricultural equipment
  • Heavy-duty transmission and torque-converter circuits

Selection pitfalls — read before you substitute

  • Line type is not interchangeable: return-line cartridges are low-collapse executions that typically tolerate roughly 10–20 bar differential, while pressure-line elements are commonly rated 100–210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
  • This element has no integral bypass — opening pressure is set by the housing’s reusable bypass valve. Confirm the valve setting (commonly 3.4 bar) is present before fitting.
  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • This execution uses nitrile (nbr) seals — verify the compound against the fluid data sheet: standard nitrile (NBR) can fail early in phosphate-ester fluids and at sustained high temperature, where fluorocarbon/Viton executions may be required.
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the 57522 filter element?
The published envelope is 78 mm OD × 210 mm length with a 43 mm inside diameter (3.071 × 8.268 in × 1.693 in ID). Confirm against the housing drawing before ordering.
What micron rating does 57522 use?
This element is rated 10 µm (nominal class) — β10 = 200. Always compare Beta ratings at the same test point: two brands may print different micron numbers for the same physical grade.
What replaces the 57522 filter element?
2 partial match(es) requiring parameter review
How do I read the 57522 part number?
See the designation decoder above: each segment of 57522 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic filter element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Same-envelope elements from other brands

View full interchange →

These 34 catalog element(s) share the 78×210 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.

Other models in the 57xxx series

All 221 →

Reviewed & verified by the ElementRef engineering desk against WIX Filters (MANN+HUMMEL) on 2026-09-28. Read our editorial & correction policy.