WIX Filters · 57xxx · return line

57520 filter element: specifications & equivalents

The 57520 is a WIX Filters return-line hydraulic filter element, built with wire/glass media, sized 126 × 289 mm OD × length (ID 91 mm), rated at 19 µm class. Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 126 × 289 mm
Inside diameter 91 mm
Filtration rating 19 µm nom.
Media Wire/Glass
Line type return
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-28. Confidence score 0.90.

Specification table

ParameterValue
Filter type return line
Media Wire/Glass
Filtration rating 19 µm
Rating basis nominal
Outside diameter OD 126 mm
Inside diameter ID 91 mm
Length 289 mm
End caps open-ended cartridge element (no baseplate)
Flow direction outside-in
Integral bypass valve none (housing/valve-dependent)
Seal material Nitrile (NBR)
Manufacturer part no. 57520
Source catalog WIX Filters (MANN+HUMMEL): WIX Filters online product catalog
Last verified2026-09-28

Sources: WIX Filters (MANN+HUMMEL) — WIX Filters online product catalog — accessed 2026-09-26.

WIX Filters® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized WIX Filters distributor.

Dimensional drawing

57520 — FILTER ELEMENTWIX Filters · 57xxx · return line · dimensional reference drawingFRONT VIEWTOP VIEW289 mmØ126 mmØ126Ø91 boreTECHNICAL DATAElement typereturn lineMediaWire/GlassRating19 µm nominalSealNitrile (NBR)Outside dia. OD126 mmInside dia. ID91 mmLength289 mmEnd capsopen-ended cartridge element (no baseplate)WIX Filters (MANN+HUMMEL) — WIX Filters online product catalog, accessed 2026-09-26NOTES1. Dimensions in millimetres, nominal values as cited in the source line above; manufacturing tolerances and interface details per the manufacturer data sheet.2. Schematic section derived from catalog data — not a manufacturer drawing. Confirm thread, end caps, seal compound and micron/Beta grade against the original element before ordering.3. ElementRef is an independent reference database; not affiliated with, authorised or endorsed by WIX Filters.ELEMENTREF · 57520DWG NO.ER-57520-DWG-01DATA DATE2026-09-28SCALE1:1.7REV.A
Reference drawing generated from the source values cited on this page — nominal envelope, schematic section, not a manufacturer drawing. The PDF is A3 landscape and vector; the PNG is sized for a WhatsApp preview. Confirm thread, end caps, seal compound and micron/Beta grade against the original element before ordering.

Dimensions & series range

Outside diameter126 mm (4.961 in)
Inside diameter91 mm (3.583 in)
Overall length289 mm (11.378 in)

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ HD13112MANN-FILTERpartialMANN-FILTER's online catalog lists 57520 (WIX) as a comparison number for HD13112. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HF28804FleetguardpartialFleetguard's online catalog lists 57520 as an interchange for HF28804. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ R731C10FiltrecpartialFiltrec's official Cross Navigator maps WIX 57520 to FILTREC R731C10 as a direct replacement, publishing the FILTREC element's OD/ID/height envelope and media grade. Rated micron differs (19 vs 10 µm) — verify efficiency class and collapse/seal for the housing before substituting.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

Full chart: WIX Filters cross reference chart →

How the 57520 model number is decoded

  • 57520WIX hydraulic cartridge element part number.
  • 126 mm OD / 91 mm IDCartridge envelope (outside/inside diameter); no mounting thread.
  • Wire/GlassFilter media: Wire/Glass.

Typical equipment & applications

  • Mobile and industrial hydraulic return circuits
  • Construction and agricultural equipment
  • Heavy-duty transmission and torque-converter circuits

Selection pitfalls — read before you substitute

  • Line type is not interchangeable: return-line cartridges are low-collapse executions that typically tolerate roughly 10–20 bar differential, while pressure-line elements are commonly rated 100–210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
  • This element has no integral bypass — opening pressure is set by the housing’s reusable bypass valve. Confirm the valve setting (commonly 3.4 bar) is present before fitting.
  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • This execution uses nitrile (nbr) seals — verify the compound against the fluid data sheet: standard nitrile (NBR) can fail early in phosphate-ester fluids and at sustained high temperature, where fluorocarbon/Viton executions may be required.
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the 57520 filter element?
The published envelope is 126 mm OD × 289 mm length with a 91 mm inside diameter (4.961 × 11.378 in × 3.583 in ID). Confirm against the housing drawing before ordering.
What micron rating does 57520 use?
This element is rated 19 µm (nominal class). Always compare Beta ratings at the same test point: two brands may print different micron numbers for the same physical grade.
What replaces the 57520 filter element?
3 partial match(es) requiring parameter review
How do I read the 57520 part number?
See the designation decoder above: each segment of 57520 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic filter element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the 57xxx series

All 221 →

Reviewed & verified by the ElementRef engineering desk against WIX Filters (MANN+HUMMEL) on 2026-09-28. Read our editorial & correction policy.