HYDAC · Betamicron 4 D/DN · pressure line
0990 DN 003 BH4HC filter element: specifications & equivalents
The 0990 DN 003 BH4HC is a HYDAC pressure-line hydraulic filter element, built with betamicron 4 microglass, high-collapse (210 bar / 3045 psi) media, rated at 3 µm absolute (βx(c) ≥ 1000 per ISO 16889). Verify against the current manufacturer data sheet before ordering.
Envelope dimensions (OD/ID/length) are pending extraction from the HYDAC electronic catalog (s2); grade, media, collapse and seal ratings are confirmed. Verify the housing drawing before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | pressure line |
| Media | Betamicron 4 microglass, high-collapse (210 bar / 3045 psi) |
| Filtration rating | 3 µm |
| Rating basis | absolute |
| Beta ratio | βx(c) ≥ 1000 per ISO 16889 |
| Flow direction | outside-in |
| Collapse / burst pressure | 210 bar |
| Integral bypass valve | none (housing/valve-dependent) |
| Seal material | Nitrile (NBR) |
| Operating temperature | -30 to 100 °C |
| Source catalog | HYDAC Technology Corporation: HYDAC Filter Elements HYDAC / Airline Hydraulics: Betamicron Filter Elements |
| Last verified | 2026-09-28 |
Sources: HYDAC Technology Corporation — HYDAC Filter Elements · HYDAC / Airline Hydraulics — Betamicron Filter Elements — accessed 2026-09-26.
HYDAC® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized HYDAC distributor.
Cross references & equivalents
No catalog-verified cross references yet. This model is in the manual verification queue — request a verified equivalent.
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
Full chart: HYDAC cross reference chart →
How the 0990 DN 003 BH4HC model number is decoded
- 0990Element size code (0990) for the DIN 24550 housing family.
- DNDIN 24550 standard envelope element.
- 0033 µm absolute class per the HYDAC electronic catalog (s2).
- BH4HCBetamicron 4 microglass, high-collapse (210 bar / 3045 psi)
Typical equipment & applications
- Pressure-line hydraulic filters upstream of control valves
- High-differential-pressure industrial hydraulic circuits
- Hydraulic power units for steel, paper and power generation
Selection pitfalls — read before you substitute
- Line type is not interchangeable: return-line cartridges are low-collapse executions that typically tolerate roughly 10–20 bar differential, while pressure-line elements are commonly rated 100–210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- This execution uses nitrile (nbr) seals — verify the compound against the fluid data sheet: standard nitrile (NBR) can fail early in phosphate-ester fluids and at sustained high temperature, where fluorocarbon/Viton executions may be required.
- Fine 3 µm media loads faster and runs at a higher cold Δp than coarser grades — only downgrade cleanliness targets if the system ISO 4406 code allows it.
Frequently asked questions
What micron rating does 0990 DN 003 BH4HC use?
What replaces the 0990 DN 003 BH4HC filter element?
How do I read the 0990 DN 003 BH4HC part number?
How often should a hydraulic filter element be replaced?
Other models in the Betamicron 4 D/DN series
All 897 (list page 1/2) →Reviewed & verified by the ElementRef engineering desk against HYDAC Technology Corporation and HYDAC / Airline Hydraulics on 2026-09-28. Read our editorial & correction policy.