HYDAC · Betamicron 4 D/DN · pressure line
0330 D 020 BH4HC filter element: specifications & equivalents
The 0330 D 020 BH4HC is a HYDAC pressure-line hydraulic filter element, built with betamicron 4 microglass, high-collapse (210 bar / 3045 psi) media, rated at 20 µm absolute (βx(c) ≥ 1000 per ISO 16889). Verify against the current manufacturer data sheet before ordering.
Envelope dimensions (OD/ID/length) are pending extraction from the HYDAC electronic catalog (s2); grade, media, collapse and seal ratings are confirmed. Verify the housing drawing before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | pressure line |
| Media | Betamicron 4 microglass, high-collapse (210 bar / 3045 psi) |
| Filtration rating | 20 µm |
| Rating basis | absolute |
| Beta ratio | βx(c) ≥ 1000 per ISO 16889 |
| Flow direction | outside-in |
| Collapse / burst pressure | 210 bar |
| Integral bypass valve | none (housing/valve-dependent) |
| Seal material | Nitrile (NBR) |
| Operating temperature | -30 to 100 °C |
| Source catalog | HYDAC Technology Corporation: HYDAC Filter Elements HYDAC / Airline Hydraulics: Betamicron Filter Elements |
| Last verified | 2026-09-27 |
Sources: HYDAC Technology Corporation — HYDAC Filter Elements · HYDAC / Airline Hydraulics — Betamicron Filter Elements — accessed 2026-09-26.
HYDAC® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized HYDAC distributor.
Cross references & equivalents
No catalog-verified cross references yet. This model is in the manual verification queue — request a verified equivalent.
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the 0330 D 020 BH4HC model number is decoded
- 0330Element size code (0330) for the HYDAC DF/DFF pressure-filter housing family.
- DPressure-line element for HYDAC DF/DFF pressure filter housings.
- 02020 µm absolute class per the HYDAC electronic catalog (s2).
- BH4HCBetamicron 4 microglass, high-collapse (210 bar / 3045 psi)
Typical equipment & applications
- Pressure-line hydraulic filters upstream of control valves
- High-differential-pressure industrial hydraulic circuits
- Hydraulic power units for steel, paper and power generation
Selection pitfalls — read before you substitute
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What micron rating does 0330 D 020 BH4HC use?
What replaces the 0330 D 020 BH4HC filter element?
How do I read the 0330 D 020 BH4HC part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Other models in the Betamicron 4 D/DN series
All 90 →Reviewed & verified by the ElementRef engineering desk against HYDAC Technology Corporation and HYDAC / Airline Hydraulics on 2026-09-27. Read our editorial & correction policy.