HYDAC · Betamicron 4 D/DN · pressure line

0250 DN 003 BH4HC filter element: specifications & equivalents

The 0250 DN 003 BH4HC is a HYDAC pressure-line hydraulic filter element, built with bh/hc=betamicron® high collapse media, sized 78.7 × 248.9 mm OD × length (ID 40.1 mm), rated at 3 µm absolute (ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000)). Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 78.7 × 248.9 mm
Inside diameter 40.1 mm
Filtration rating 3 µm abs.
Beta rating ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000)
Media BH/HC=Betamicron® High Collapse
Collapse / burst 210 bar
Line type pressure
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-28. Confidence score 0.92.

Dimensions, ratings and seal compound are taken directly from the HYDAC electronic catalog (catalog.hydac.com). Outside diameter and length are converted from the inch values printed on the catalog page; verify against the current HYDAC data sheet before ordering.

Specification table

ParameterValue
Filter type pressure line
Media BH/HC=Betamicron® High Collapse
Filtration rating 3 µm
Rating basis absolute
Beta ratio ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000)
Outside diameter OD 78.7 mm
Inside diameter ID 40.1 mm
Length 248.9 mm
End caps open-ended cartridge element
Flow direction outside-in
Collapse / burst pressure 210 bar
Integral bypass valve none (housing/valve-dependent)
Seal material Nitrile (Buna-N)
Operating temperature -30 to 100 °C
Source catalog HYDAC Technology Corporation: HYDAC electronic product catalog (catalog.hydac.com)
Last verified2026-09-28

Sources: HYDAC Technology Corporation — HYDAC electronic product catalog (catalog.hydac.com) — accessed 2026-10-16.

HYDAC® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized HYDAC distributor.

Dimensional drawing

0250 DN 003 BH4HC — FILTER ELEMENTHYDAC · Betamicron 4 D/DN · pressure line · dimensional reference drawingFRONT VIEWTOP VIEW248.9 mmØ78.7 mmØ78.7Ø40.1 boreTECHNICAL DATAElement typepressure lineMediaBH/HC=Betamicron® High CollapseRating3 µm absoluteBeta ratioßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000)SealNitrile (Buna-N)Collapse210 barOperating temp-30 … 100 °COutside dia. OD78.7 mmInside dia. ID40.1 mmLength248.9 mmEnd capsopen-ended cartridge elementHYDAC Technology Corporation — HYDAC electronic product catalog (catalog.hydac.com),accessed 2026-10-16NOTES1. Dimensions in millimetres, nominal values as cited in the source line above; manufacturing tolerances and interface details per the manufacturer data sheet.2. Schematic section derived from catalog data — not a manufacturer drawing. Confirm thread, end caps, seal compound and micron/Beta grade against the original element before ordering.3. ElementRef is an independent reference database; not affiliated with, authorised or endorsed by HYDAC.ELEMENTREF · 0250 DN 003 BH4HCDWG NO.ER-0250 DN 003 BH4HC-DWG-01DATA DATE2026-09-28SCALE1:1.5REV.A
Reference drawing generated from the source values cited on this page — nominal envelope, schematic section, not a manufacturer drawing. The PDF is A3 landscape and vector; the PNG is sized for a WhatsApp preview. Confirm thread, end caps, seal compound and micron/Beta grade against the original element before ordering.

Dimensions & series range

Outside diameter78.7 mm (3.098 in)
Inside diameter40.1 mm (1.579 in)
Overall length248.9 mm (9.799 in)

All 79×249 mm interchange elements →

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ NL-250-F-03-BSTAUFFpartialSTAUFF Filter Interchange lists 0250 DN 003 BH4HC (HYDAC) as replaced by NL-250-F-03-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ XD250G03BFiltrecpartialFiltrec's official Cross Navigator maps HYDAC 0250DN003BH4HC to FILTREC XD250G03B as a direct replacement, publishing the FILTREC element's OD/ID/height envelope and media grade. Rated micron differs (3 vs 5 µm) — verify efficiency class and collapse/seal for the housing before substituting.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

Full chart: HYDAC cross reference chart →

How the 0250 DN 003 BH4HC model number is decoded

  • 0250 DN 003 BH4HCHYDAC Type DN filter element ordering code per the HYDAC electronic catalog (s16).
  • BH/HC=Betamicron® High CollapseFilter media and collapse family as printed in the catalog.
  • 3 µmAbsolute filter rating per the HYDAC catalog.
  • ßx(c) ≥ 1000Beta ratio rating as printed in the catalog.
  • 78.7 mmOutside diameter.
  • 40.1 mmInner diameter.
  • 248.9 mmElement length.
  • 210 barElement collapse (differential pressure) rating.
  • Nitrile (Buna-N)Seal compound.

Typical equipment & applications

  • Pressure-line filtration for HYDAC DF/DFF and equivalent housings
  • Industrial and mobile hydraulic systems

Selection pitfalls — read before you substitute

  • Line type is not interchangeable: return-line cartridges are low-collapse executions that typically tolerate roughly 10–20 bar differential, while pressure-line elements are commonly rated 100–210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • This execution uses nitrile (buna-n) seals — verify the compound against the fluid data sheet: standard nitrile (NBR) can fail early in phosphate-ester fluids and at sustained high temperature, where fluorocarbon/Viton executions may be required.
  • Fine 3 µm media loads faster and runs at a higher cold Δp than coarser grades — only downgrade cleanliness targets if the system ISO 4406 code allows it.
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the 0250 DN 003 BH4HC filter element?
The published envelope is 78.7 mm OD × 248.9 mm length with a 40.1 mm inside diameter (3.098 × 9.799 in × 1.579 in ID). Confirm against the housing drawing before ordering.
What micron rating does 0250 DN 003 BH4HC use?
This element is rated 3 µm absolute — ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000). Always compare Beta ratings at the same test point: two brands may print different micron numbers for the same physical grade.
What replaces the 0250 DN 003 BH4HC filter element?
2 partial match(es) requiring parameter review
How do I read the 0250 DN 003 BH4HC part number?
See the designation decoder above: each segment of 0250DN003BH4HC encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic filter element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Same-envelope elements from other brands

View full interchange →

These 29 catalog element(s) share the 79×249 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.

Other models in the Betamicron 4 D/DN series

All 897 (list page 1/2) →

Reviewed & verified by the ElementRef engineering desk against HYDAC Technology Corporation on 2026-09-28. Read our editorial & correction policy.