Filtrec · Filtrec elements · inline line
R261G10 filter element: specifications & equivalents
The R261G10 is a Filtrec inline-line hydraulic filter element, built with glassfiber media, sized 130 × 250 mm OD × length (ID 76 mm), rated at 12 µm absolute (β12(c)≥1000). Verify against the current manufacturer data sheet before ordering.
Dimensions and media grade are taken from Filtrec’s official Cross Navigator, which maps this element to specific competitor part numbers. Filtrec does not publish collapse pressure or seal compound in this API for every code — verify collapse rating, seal execution and bypass setting against the current Filtrec data sheet for the target housing before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | inline line |
| Media | glassfiber |
| Filtration rating | 12 µm |
| Rating basis | absolute |
| Beta ratio | β12(c)≥1000 |
| Outside diameter OD | 130 mm |
| Inside diameter ID | 76 mm |
| Length | 250 mm |
| Integral bypass valve | none (housing/valve-dependent) |
| Manufacturer part no. | R261G10 |
| Source catalog | Filtrec S.p.A.: Filtrec Cross Navigator |
| Last verified | 2026-10-03 |
Sources: Filtrec S.p.A. — Filtrec Cross Navigator — accessed 2026-10-03.
Filtrec® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Filtrec distributor.
Dimensional drawing
Dimensions & series range
| Outside diameter | 130 mm (5.118 in) |
| Inside diameter | 76 mm (2.992 in) |
| Overall length | 250 mm (9.843 in) |
All 130×250 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
| ↔ CU630A10N | MP Filtri | full | Filtrec's official Cross Navigator maps MP FILTRI CU630A10N to FILTREC R261G10 as a direct replacement, publishing the FILTREC element's OD/ID/height envelope and media grade. |
|
↔ FBH30M10A page in verification queue | Aftermarket | full | Filtrec's official Cross Navigator maps FBN FBH30M10A to FILTREC R261G10 as a direct replacement, publishing the FILTREC element's OD/ID/height envelope and media grade. |
|
↔ P05109810X page in verification queue | Donaldson | full | Filtrec's official Cross Navigator maps FLUITEK P05109810X to FILTREC R261G10 as a direct replacement, publishing the FILTREC element's OD/ID/height envelope and media grade. |
|
↔ RUM166G10B page in verification queue | Aftermarket | full | Filtrec's official Cross Navigator maps STAUFF RUM166G10B to FILTREC R261G10 as a direct replacement, publishing the FILTREC element's OD/ID/height envelope and media grade. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
Full chart: Filtrec cross reference chart →
How the R261G10 model number is decoded
- G10Filtrec internal media grade code (glassfiber, 12 µm).
Typical equipment & applications
- Filtrec aftermarket replacement hydraulic/lube filter element (R family), form-fit-function cross-referenced in Filtrec's official Cross Navigator.
Selection pitfalls — read before you substitute
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
Frequently asked questions
What are the dimensions of the R261G10 filter element?
What micron rating does R261G10 use?
What replaces the R261G10 filter element?
Is a same-envelope aftermarket element always a drop-in replacement?
Same-envelope elements from other brands
View full interchange →These 31 catalog element(s) share the 130×250 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.
Other models in the Filtrec elements series
All 9874 (list page 10/20) →Reviewed & verified by the ElementRef engineering desk against Filtrec S.p.A. on 2026-10-03. Read our editorial & correction policy.