Envelope interchange · 4.49×31.18 in

114×792 mm filter elements

128 elements from 4 brand(s) share this envelope: 114 mm outside diameter and 792 mm overall length (4.49×31.18 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
RE-240-B-100-V STAUFF 68.4 — — — housing — inline
RE-240-B-50-B STAUFF 68.4 — — — housing — inline
RE-240-G-03-B STAUFF 68.3 — — — housing — inline
RE-240-G-03-B-B6.0 STAUFF 68.3 — — — housing — inline
RE-240-G-03-B-NB STAUFF 68.3 — — — housing — inline
RE-240-G-03-V STAUFF 68.3 — — — housing — inline
RE-240-G-03-V-NB STAUFF 68.3 — — — housing — inline
RE-240-G-05-B STAUFF 68.3 — — — housing — inline
RE-240-G-05-B-B6.0 STAUFF 68.3 — — — housing — inline
RE-240-G-05-B-NB STAUFF 68.3 — — — housing — inline
RE-240-G-05-V STAUFF 68.3 — — — housing — inline
RE-240-G-10-B STAUFF 68.3 — — — housing — inline
RE-240-G-10-B-B1.0 STAUFF 68.3 — — — housing — inline
RE-240-G-10-B-B6.0 STAUFF 68.3 — — — housing — inline
RE-240-G-10-B-NB STAUFF 68.3 — — — housing — inline
RE-240-G-10-V STAUFF 68.3 — — — housing — inline
RE-240-G-20-B STAUFF 68.3 — — — housing — inline
RE-240-G-20-B-B6.0 STAUFF 68.3 — — — housing — inline
RE-240-G-20-B-NB STAUFF 68.3 — — — housing — inline
RE-240-G-20-V STAUFF 68.3 — — — housing — inline
RE-240-GP-05-B-NB STAUFF 68.3 — — — housing — inline
RE-240-GP-10-B-NB STAUFF 68.3 — — — housing — inline
RE-240-N-10-B STAUFF 68.3 — — — housing — inline
RE-240-N-20-B STAUFF 68.3 — — — housing — inline
RE-240-S-100-B STAUFF 68.3 — — — housing — inline
RE-240-S-100-B-B6.0 STAUFF 68.3 — — — housing — inline
RE-240-S-100-B-NB STAUFF 68.3 — — — housing — inline
RE-240-S-100-V STAUFF 68.3 — — — housing — inline
RE-240-S-200-B STAUFF 68.3 — — — housing — inline
RE-240-S-200-B-B6.0 STAUFF 68.3 — — — housing — inline
RE-240-S-200-V STAUFF 68.3 — — — housing — inline
RE-240-S-25-B STAUFF 68.3 — — — housing — inline
RE-240-S-25-B-B6.0 STAUFF 68.3 — — — housing — inline
RE-240-S-25-B-NB STAUFF 68.3 — — — housing — inline
RE-240-S-25-V STAUFF 68.3 — — — housing — inline
RE-240-S-50-B STAUFF 68.3 — — — housing — inline
RE-240-S-50-B-B6.0 STAUFF 68.3 — — — housing — inline
RE-240-S-50-B-NB STAUFF 68.3 — — — housing — inline
RE-240-S-50-V STAUFF 68.3 — — — housing — inline
R3.1280-53K1 ARGO-HYTOS 68.3 5 — 10 housing — inline
R3.1280-56K1 ARGO-HYTOS 68.3 10 — 10 housing — inline
R3.1280-58K1 ARGO-HYTOS 68.3 16 — 10 housing — inline
02.1700 R.25G.30.HC.S.P Eaton / Internormen — 25 — 30 housing Nitrile (Buna-N) inline
RHR1700A10B Filtrec 68.5 — — — housing — inline
RHR1700AW40B0/AB1 Filtrec 68.4 — — — housing — inline
RHR1700AW40B3/AB1 Filtrec 68.4 — — — housing — inline
RHR1700AW40V0/AB1 Filtrec 68.4 — — — housing — inline
RHR1700AW40V3/AB1 Filtrec 68.4 — — — housing — inline
RHR1700G01B0/AB1 Filtrec 68.4 4 β4(c)≥1000 — housing — inline
RHR1700G01B0/ESD Filtrec 68.4 4 β4(c)≥1000 — housing — inline
RHR1700G03B0/AB1 Filtrec 68.4 5 β5(c)≥1000 — housing — inline
RHR1700G03B0/ESD Filtrec 68.4 5 β5(c)≥1000 — housing — inline
RHR1700G03B1/ESD Filtrec 68.4 5 β5(c)≥1000 — housing — inline
RHR1700G03B3/AB1 Filtrec 68.4 5 β5(c)≥1000 — housing — inline
RHR1700G03B6/AB1 Filtrec 68.4 5 β5(c)≥1000 — housing — inline
RHR1700G03B6/ESD Filtrec 68.4 5 β5(c)≥1000 — housing — inline
RHR1700G03B/ESD Filtrec 68.5 5 β5(c)≥1000 — housing — inline
RHR1700G03V0/AB1 Filtrec 68.4 5 β5(c)≥1000 — housing — inline
RHR1700G03V0/ESD Filtrec 68.4 5 β5(c)≥1000 — housing — inline
RHR1700G03V1/ESD Filtrec 68.4 5 β5(c)≥1000 — housing — inline
RHR1700G03V3/AB1 Filtrec 68.4 5 β5(c)≥1000 — housing — inline
RHR1700G03V6/AB1 Filtrec 68.4 5 β5(c)≥1000 — housing — inline
RHR1700G03V6/ESD Filtrec 68.4 5 β5(c)≥1000 — housing — inline
RHR1700G03V/ESD Filtrec 68.5 5 β5(c)≥1000 — housing — inline
RHR1700G05B0/AB1 Filtrec 68.4 7 β7(c)≥1000 — housing — inline
RHR1700G05B0/ESD Filtrec 68.4 7 β7(c)≥1000 — housing — inline
RHR1700G05B1/ESD Filtrec 68.4 7 β7(c)≥1000 — housing — inline
RHR1700G05B3/AB1 Filtrec 68.4 7 β7(c)≥1000 — housing — inline
RHR1700G05B6/AB1 Filtrec 68.4 7 β7(c)≥1000 — housing — inline
RHR1700G05B6/ESD Filtrec 68.4 7 β7(c)≥1000 — housing — inline
RHR1700G05B/ESD Filtrec 68.5 7 β7(c)≥1000 — housing — inline
RHR1700G05V0/AB1 Filtrec 68.4 7 β7(c)≥1000 — housing — inline
RHR1700G05V0/ESD Filtrec 68.4 7 β7(c)≥1000 — housing — inline
RHR1700G05V1/ESD Filtrec 68.4 7 β7(c)≥1000 — housing — inline
RHR1700G05V3/AB1 Filtrec 68.4 7 β7(c)≥1000 — housing — inline
RHR1700G05V6/AB1 Filtrec 68.4 7 β7(c)≥1000 — housing — inline
RHR1700G05V6/ESD Filtrec 68.4 7 β7(c)≥1000 — housing — inline
RHR1700G05V/ESD Filtrec 68.5 7 β7(c)≥1000 — housing — inline
RHR1700G10B0/AB1 Filtrec 68.4 12 β12(c)≥1000 — housing — inline
RHR1700G10B0/ESD Filtrec 68.4 12 β12(c)≥1000 — housing — inline
RHR1700G10B1/ESD Filtrec 68.4 12 β12(c)≥1000 — housing — inline
RHR1700G10B3/AB1 Filtrec 68.4 12 β12(c)≥1000 — housing — inline
RHR1700G10B6/AB1 Filtrec 68.4 12 β12(c)≥1000 — housing — inline
RHR1700G10B6/ESD Filtrec 68.4 12 β12(c)≥1000 — housing — inline
RHR1700G10B/ESD Filtrec 68.5 12 β12(c)≥1000 — housing — inline
RHR1700G10V0/AB1 Filtrec 68.4 12 β12(c)≥1000 — housing — inline
RHR1700G10V0/ESD Filtrec 68.4 12 β12(c)≥1000 — housing — inline
RHR1700G10V1/ESD Filtrec 68.4 12 β12(c)≥1000 — housing — inline
RHR1700G10V3/AB1 Filtrec 68.4 12 β12(c)≥1000 — housing — inline
RHR1700G10V6/AB1 Filtrec 68.4 12 β12(c)≥1000 — housing — inline
RHR1700G10V6/ESD Filtrec 68.4 12 β12(c)≥1000 — housing — inline
RHR1700G10V/ESD Filtrec 68.5 12 β12(c)≥1000 — housing — inline
RHR1700G20B0/AB1 Filtrec 68.4 22 β22(c)≥1000 — housing — inline
RHR1700G20B0/ESD Filtrec 68.4 22 β22(c)≥1000 — housing — inline
RHR1700G20B1/ESD Filtrec 68.4 22 β22(c)≥1000 — housing — inline
RHR1700G20B3/AB1 Filtrec 68.4 22 β22(c)≥1000 — housing — inline
RHR1700G20B6/AB1 Filtrec 68.4 22 β22(c)≥1000 — housing — inline
RHR1700G20B6/ESD Filtrec 68.4 22 β22(c)≥1000 — housing — inline
RHR1700G20B/ESD Filtrec 68.5 22 β22(c)≥1000 — housing — inline
RHR1700G20V0/AB1 Filtrec 68.4 22 β22(c)≥1000 — housing — inline
RHR1700G20V0/ESD Filtrec 68.4 22 β22(c)≥1000 — housing — inline
RHR1700G20V1/ESD Filtrec 68.4 22 β22(c)≥1000 — housing — inline
RHR1700G20V3/AB1 Filtrec 68.4 22 β22(c)≥1000 — housing — inline
RHR1700G20V6/AB1 Filtrec 68.4 22 β22(c)≥1000 — housing — inline
RHR1700G20V6/ESD Filtrec 68.4 22 β22(c)≥1000 — housing — inline
RHR1700G20V/ESD Filtrec 68.5 22 β22(c)≥1000 — housing — inline
RHR1700M05B0/AB1 Filtrec 68.4 10 β10(c)≥1000 — housing — inline
RHR1700M05B3/AB1 Filtrec 68.4 10 β10(c)≥1000 — housing — inline
RHR1700M05V3/AB1 Filtrec 68.4 10 β10(c)≥1000 — housing — inline
RHR1700M10B0/AB1 Filtrec 68.4 15 β15(c)≥1000 — housing — inline
RHR1700M10B0/ESD Filtrec 68.4 15 β15(c)≥1000 — housing — inline
RHR1700M10B3/AB1 Filtrec 68.4 15 β15(c)≥1000 — housing — inline
RHR1700M10V3/AB1 Filtrec 68.4 15 β15(c)≥1000 — housing — inline
RHR1700M20B0/AB1 Filtrec 68.4 — — — housing — inline
RHR1700M20B3/AB1 Filtrec 68.4 — — — housing — inline
RHR1700M20V3/AB1 Filtrec 68.4 — — — housing — inline
RHR1700N10B3/AB1 Filtrec 68.4 10 β10(c)≥2 — housing — inline
RHR1700N10V3/AB1 Filtrec 68.4 10 β10(c)≥2 — housing — inline
RHR1700N20B3/AB1 Filtrec 68.4 — — — housing — inline
RHR1700S100B0/AB1 Filtrec 68.4 100 — — housing — inline
RHR1700S100B3/AB1 Filtrec 68.4 100 — — housing — inline
RHR1700S100B6/AB1 Filtrec 68.4 100 — — housing — inline
RHR1700S100V3/AB1 Filtrec 68.4 100 — — housing — inline
RHR1700S25B3/AB1 Filtrec 68.4 25 — — housing — inline
RHR1700S50B0/AB1 Filtrec 68.4 50 — — housing — inline
RHR1700S50B3/AB1 Filtrec 68.4 50 — — housing — inline
RHR1700S50B6/AB1 Filtrec 68.4 50 — — housing — inline
RHR1700S50V3/AB1 Filtrec 68.4 50 — — housing — inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 114×792 mm filter elements interchangeable?
They share the same physical envelope — 114 mm OD and 792 mm length (4.49×31.18 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 128 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 114×792 mm in inches?
114×792 mm converts to approximately 4.49×31.18 in.

Browse all 114 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.