WIX Filters · 57xxx · return line

57598 filter element: specifications & equivalents

The 57598 is a WIX Filters return-line hydraulic filter element, built with glass media, sized 81 × 235 mm OD × length (ID 41 mm), rated at 10 µm class. Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 81 × 235 mm
Inside diameter 41 mm
Filtration rating 10 µm nom.
Media Glass
Line type return
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-28. Confidence score 0.90.

Specification table

ParameterValue
Filter type return line
Media Glass
Filtration rating 10 µm
Rating basis nominal
Outside diameter OD 81 mm
Inside diameter ID 41 mm
Length 235 mm
End caps open-ended cartridge element (no baseplate)
Flow direction outside-in
Integral bypass valve none (housing/valve-dependent)
Seal material Nitrile (NBR)
Manufacturer part no. 57598
Source catalog WIX Filters (MANN+HUMMEL): WIX Filters online product catalog
Last verified2026-09-28

Sources: WIX Filters (MANN+HUMMEL) — WIX Filters online product catalog — accessed 2026-09-26.

WIX Filters® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized WIX Filters distributor.

Dimensional drawing

57598 — FILTER ELEMENTWIX Filters · 57xxx · return line · dimensional reference drawingFRONT VIEWTOP VIEW235 mmØ81 mmØ81Ø41 boreTECHNICAL DATAElement typereturn lineMediaGlassRating10 µm nominalSealNitrile (NBR)Outside dia. OD81 mmInside dia. ID41 mmLength235 mmEnd capsopen-ended cartridge element (no baseplate)WIX Filters (MANN+HUMMEL) — WIX Filters online product catalog, accessed 2026-09-26NOTES1. Dimensions in millimetres, nominal values as cited in the source line above; manufacturing tolerances and interface details per the manufacturer data sheet.2. Schematic section derived from catalog data — not a manufacturer drawing. Confirm thread, end caps, seal compound and micron/Beta grade against the original element before ordering.3. ElementRef is an independent reference database; not affiliated with, authorised or endorsed by WIX Filters.ELEMENTREF · 57598DWG NO.ER-57598-DWG-01DATA DATE2026-09-28SCALE1:1.4REV.A
Reference drawing generated from the source values cited on this page — nominal envelope, schematic section, not a manufacturer drawing. The PDF is A3 landscape and vector; the PNG is sized for a WhatsApp preview. Confirm thread, end caps, seal compound and micron/Beta grade against the original element before ordering.

Dimensions & series range

Outside diameter81 mm (3.189 in)
Inside diameter41 mm (1.614 in)
Overall length235 mm (9.252 in)

All 81×235 mm interchange elements →

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ D650G10BVFiltrecpartialFiltrec's official Cross Navigator maps WIX 57598 to FILTREC D650G10BV as a direct replacement, publishing the FILTREC element's OD/ID/height envelope and media grade. Rated micron differs (10 vs 12 µm) — verify efficiency class and collapse/seal for the housing before substituting.
↔ HF30267FleetguardpartialFleetguard's online catalog lists 57598 as an interchange for HF30267. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

Full chart: WIX Filters cross reference chart →

How the 57598 model number is decoded

  • 57598WIX hydraulic cartridge element part number.
  • 81 mm OD / 41 mm IDCartridge envelope (outside/inside diameter); no mounting thread.
  • GlassFilter media: Glass.

Typical equipment & applications

  • Mobile and industrial hydraulic return circuits
  • Construction and agricultural equipment
  • Heavy-duty transmission and torque-converter circuits

Selection pitfalls — read before you substitute

  • Line type is not interchangeable: return-line cartridges are low-collapse executions that typically tolerate roughly 10–20 bar differential, while pressure-line elements are commonly rated 100–210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
  • This element has no integral bypass — opening pressure is set by the housing’s reusable bypass valve. Confirm the valve setting (commonly 3.4 bar) is present before fitting.
  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • This execution uses nitrile (nbr) seals — verify the compound against the fluid data sheet: standard nitrile (NBR) can fail early in phosphate-ester fluids and at sustained high temperature, where fluorocarbon/Viton executions may be required.
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the 57598 filter element?
The published envelope is 81 mm OD × 235 mm length with a 41 mm inside diameter (3.189 × 9.252 in × 1.614 in ID). Confirm against the housing drawing before ordering.
What micron rating does 57598 use?
This element is rated 10 µm (nominal class). Always compare Beta ratings at the same test point: two brands may print different micron numbers for the same physical grade.
What replaces the 57598 filter element?
2 partial match(es) requiring parameter review
How do I read the 57598 part number?
See the designation decoder above: each segment of 57598 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic filter element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Same-envelope elements from other brands

View full interchange →

These 3 catalog element(s) share the 81×235 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.

Other models in the 57xxx series

All 221 →

Reviewed & verified by the ElementRef engineering desk against WIX Filters (MANN+HUMMEL) on 2026-09-28. Read our editorial & correction policy.