WIX Filters · 57xxx · return line

57045 filter element: specifications & equivalents

The 57045 is a WIX Filters return-line hydraulic filter element, built with enhanced cellulose media, sized 74.7 × 122.6 mm OD × length, rated at 21 µm class (β2 = 6, β20 = 20). Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 74.7 × 122.6 mm
Filtration rating 21 µm nom.
Beta rating β 2 = 6, β20 = 20
Media Enhanced Cellulose
Thread M22x1.5
Collapse / burst 24.131 bar
Line type return
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-28. Confidence score 0.90.

Specification table

ParameterValue
Filter type return line
Media Enhanced Cellulose
Filtration rating 21 µm
Rating basis nominal
Beta ratio β2 = 6, β20 = 20
Outside diameter OD 74.7 mm
Length 122.6 mm
Thread / connection M22x1.5
End caps spin-on baseplate with attached gasket
Flow direction outside-in
Collapse / burst pressure 24.131 bar
Integral bypass valve opens at 0.827 bar
Seal material Nitrile (NBR)
Manufacturer part no. 57045
Source catalog WIX Filters (MANN+HUMMEL): WIX Filters online product catalog
Last verified2026-09-28

Sources: WIX Filters (MANN+HUMMEL) — WIX Filters online product catalog — accessed 2026-09-26.

WIX Filters® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized WIX Filters distributor.

Dimensional drawing

57045 — FILTER ELEMENTWIX Filters · 57xxx · return line · dimensional reference drawingFRONT VIEWBASE VIEWThread M22x1.5122.6 mmØ74.7 mmØ74.7M22x1.5 threadTECHNICAL DATAElement typereturn lineMediaEnhanced CelluloseRating21 µm nominalBeta ratioβ2 = 6, β20 = 20SealNitrile (NBR)Collapse24.1 barOutside dia. OD74.7 mmLength122.6 mmThreadM22x1.5End capsspin-on baseplate with attached gasketWIX Filters (MANN+HUMMEL) — WIX Filters online product catalog, accessed 2026-09-26NOTES1. Dimensions in millimetres, nominal values as cited in the source line above; manufacturing tolerances and interface details per the manufacturer data sheet.2. Schematic section derived from catalog data — not a manufacturer drawing. Confirm thread, end caps, seal compound and micron/Beta grade against the original element before ordering.3. ElementRef is an independent reference database; not affiliated with, authorised or endorsed by WIX Filters.ELEMENTREF · 57045DWG NO.ER-57045-DWG-01DATA DATE2026-09-28SCALE1.1:1REV.A
Reference drawing generated from the source values cited on this page — nominal envelope, schematic section, not a manufacturer drawing. The PDF is A3 landscape and vector; the PNG is sized for a WhatsApp preview. Confirm thread, end caps, seal compound and micron/Beta grade against the original element before ordering.

Dimensions & series range

Outside diameter74.7 mm (2.941 in)
Overall length122.6 mm (4.827 in)

Cross references & equivalents

No catalog-verified cross references yet. This model is in the manual verification queue — request a verified equivalent.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

Full chart: WIX Filters cross reference chart →

How the 57045 model number is decoded

  • 57045WIX lube spin-on filter part number.
  • M22x1.5Mounting thread: M22x1.5 (spin-on baseplate).
  • Enhanced CelluloseFilter media: Enhanced Cellulose.

Typical equipment & applications

  • Engine lubrication circuits on heavy-duty equipment
  • Construction and agricultural machinery
  • Industrial and marine diesel engines

Selection pitfalls — read before you substitute

  • Line type is not interchangeable: return-line cartridges are low-collapse executions that typically tolerate roughly 10–20 bar differential, while pressure-line elements are commonly rated 100–210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
  • This execution carries an integral bypass valve (opens at 0.827 bar). The same envelope also exists without it, relying on the housing valve. Mixing the two strategies changes cold-start protection — match what was installed originally.
  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • This execution uses nitrile (nbr) seals — verify the compound against the fluid data sheet: standard nitrile (NBR) can fail early in phosphate-ester fluids and at sustained high temperature, where fluorocarbon/Viton executions may be required.
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the 57045 filter element?
The published envelope is 74.7 mm OD × 122.6 mm length (2.941 × 4.827 in). Confirm against the housing drawing before ordering.
What micron rating does 57045 use?
This element is rated 21 µm (nominal class) — β2 = 6, β20 = 20. Always compare Beta ratings at the same test point: two brands may print different micron numbers for the same physical grade.
What replaces the 57045 filter element?
Cross references are being verified for this model — use the inquiry form and the engineering desk will confirm equivalents.
How do I read the 57045 part number?
See the designation decoder above: each segment of 57045 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic filter element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the 57xxx series

All 221 →

Reviewed & verified by the ElementRef engineering desk against WIX Filters (MANN+HUMMEL) on 2026-09-28. Read our editorial & correction policy.