WIX Filters · 51xxx · return line

51862 filter element: specifications & equivalents

The 51862 is a WIX Filters return-line hydraulic filter element, built with wire/paper media, sized 114.3 × 248.5 mm OD × length (ID 57.5 mm), rated at 9 µm class. Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 114.3 × 248.5 mm
Inside diameter 57.5 mm
Filtration rating 9 µm nom.
Media Wire/Paper
Line type return
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-28. Confidence score 0.90.

Specification table

ParameterValue
Filter type return line
Media Wire/Paper
Filtration rating 9 µm
Rating basis nominal
Outside diameter OD 114.3 mm
Inside diameter ID 57.5 mm
Length 248.5 mm
End caps open-ended cartridge element (no baseplate)
Flow direction outside-in
Integral bypass valve none (housing/valve-dependent)
Seal material Nitrile (NBR)
Manufacturer part no. 51862
Source catalog WIX Filters (MANN+HUMMEL): WIX Filters online product catalog
Last verified2026-09-28

Sources: WIX Filters (MANN+HUMMEL) — WIX Filters online product catalog — accessed 2026-09-26.

WIX Filters® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized WIX Filters distributor.

Dimensional drawing

51862 — FILTER ELEMENTWIX Filters · 51xxx · return line · dimensional reference drawingFRONT VIEWTOP VIEW248.5 mmØ114.3 mmØ114.3Ø57.5 boreTECHNICAL DATAElement typereturn lineMediaWire/PaperRating9 µm nominalSealNitrile (NBR)Outside dia. OD114.3 mmInside dia. ID57.5 mmLength248.5 mmEnd capsopen-ended cartridge element (no baseplate)WIX Filters (MANN+HUMMEL) — WIX Filters online product catalog, accessed 2026-09-26NOTES1. Dimensions in millimetres, nominal values as cited in the source line above; manufacturing tolerances and interface details per the manufacturer data sheet.2. Schematic section derived from catalog data — not a manufacturer drawing. Confirm thread, end caps, seal compound and micron/Beta grade against the original element before ordering.3. ElementRef is an independent reference database; not affiliated with, authorised or endorsed by WIX Filters.ELEMENTREF · 51862DWG NO.ER-51862-DWG-01DATA DATE2026-09-28SCALE1:1.5REV.A
Reference drawing generated from the source values cited on this page — nominal envelope, schematic section, not a manufacturer drawing. The PDF is A3 landscape and vector; the PNG is sized for a WhatsApp preview. Confirm thread, end caps, seal compound and micron/Beta grade against the original element before ordering.

Dimensions & series range

Outside diameter114.3 mm (4.500 in)
Inside diameter57.5 mm (2.264 in)
Overall length248.5 mm (9.783 in)

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ HF6481FleetguardpartialFleetguard's online catalog lists 51862 as an interchange for HF6481. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

Full chart: WIX Filters cross reference chart →

How the 51862 model number is decoded

  • 51862WIX hydraulic cartridge element part number.
  • 114.3 mm OD / 57.5 mm IDCartridge envelope (outside/inside diameter); no mounting thread.
  • Wire/PaperFilter media: Wire/Paper.

Typical equipment & applications

  • Mobile and industrial hydraulic return circuits
  • Construction and agricultural equipment
  • Heavy-duty transmission and torque-converter circuits

Selection pitfalls — read before you substitute

  • Line type is not interchangeable: return-line cartridges are low-collapse executions that typically tolerate roughly 10–20 bar differential, while pressure-line elements are commonly rated 100–210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
  • This element has no integral bypass — opening pressure is set by the housing’s reusable bypass valve. Confirm the valve setting (commonly 3.4 bar) is present before fitting.
  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • This execution uses nitrile (nbr) seals — verify the compound against the fluid data sheet: standard nitrile (NBR) can fail early in phosphate-ester fluids and at sustained high temperature, where fluorocarbon/Viton executions may be required.
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the 51862 filter element?
The published envelope is 114.3 mm OD × 248.5 mm length with a 57.5 mm inside diameter (4.500 × 9.783 in × 2.264 in ID). Confirm against the housing drawing before ordering.
What micron rating does 51862 use?
This element is rated 9 µm (nominal class). Always compare Beta ratings at the same test point: two brands may print different micron numbers for the same physical grade.
What replaces the 51862 filter element?
1 partial match(es) requiring parameter review
How do I read the 51862 part number?
See the designation decoder above: each segment of 51862 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic filter element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the 51xxx series

All 306 →

Reviewed & verified by the ElementRef engineering desk against WIX Filters (MANN+HUMMEL) on 2026-09-28. Read our editorial & correction policy.