STAUFF · Replacement Elements · inline line

SP-030-E-20-B filter element: specifications & equivalents

The SP-030-E-20-B is a STAUFF inline-line hydraulic filter element, sized 49.5 × 207 mm OD × length (ID 23.9 mm). Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 49.5 × 207 mm
Inside diameter 23.9 mm
Line type inline
Partially verified. Fit and grade trace to an official interchange document; dimensional values are compiled from 0 aftermarket listing(s) and must be confirmed against the manufacturer housing drawing. Confidence score 0.85.

Micron rating, media type, collapse pressure and seal material are not printed in the STAUFF interchange listing and are pending extraction from STAUFF product data sheets. Verify against the current STAUFF catalog before ordering.

Specification table

ParameterValue
Filter type inline line
Outside diameter OD 49.5 mm
Inside diameter ID 23.9 mm
Length 207 mm
End caps open-ended cartridge element
Integral bypass valve none (housing/valve-dependent)
Source catalog STAUFF: STAUFF Filter Interchange online database (filterinterchange.com)
Last verified2026-09-27

Sources: STAUFF — STAUFF Filter Interchange online database (filterinterchange.com) — accessed 2026-09-27.

STAUFF® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized STAUFF distributor.

Dimensions & series range

Outside diameter49.5 mm (1.949 in)
Inside diameter23.9 mm (0.941 in)
Overall length207 mm (8.150 in)

All 50×207 mm interchange elements →

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ 07993000
page in verification queue
UFIpartialSTAUFF Filter Interchange lists 07993000 (BOMAG) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 1111709001
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 1111709001 (FINNFILTER) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 11308D25BN
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 1.13.08D25BN (HYDAC) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 1551101001
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 1551101001 (TAKEUCHI) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 306685
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 306685 (KVERNELAND) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 3799282M1
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 3799282M1 (MASSEY-FERGUSON) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 6005003243
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 6005003243 (RENAULT) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 77788482
page in verification queue
UFIpartialSTAUFF Filter Interchange lists 77788482 (COMEX / Ecoparts) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 7788482
page in verification queue
UFIpartialSTAUFF Filter Interchange lists 778.848.2 (MAHLE / Filtration Group) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 930194
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 930194 (PARKER) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 930194Q
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 930194Q (PARKER) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 9327446
page in verification queue
UFIpartialSTAUFF Filter Interchange lists 9327446 (PUROLATOR) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 9800825UM
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 9800825UM (TRIBOGUARD) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ H980008025BN
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists H9800/08 025 BN (HYDAC) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ HD5176
page in verification queue
MANN-FILTERpartialSTAUFF Filter Interchange lists HD 517/6 (MANN-Filter) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ HY9319
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists HY 9319 (SF-FILTER) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ STU193
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists STU-193 (NORMAN) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ T1551101001
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists T1551101001 (TAKEUCHI) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ WGPT9808
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists WGPT 9808 (WOODGATE) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ WHE214528
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists WHE214528 (WISMET) as replaced by SP-030-E-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the SP-030-E-20-B model number is decoded

  • SP-030-E-20-BSTAUFF replacement element part number per the STAUFF Filter Interchange database.

Typical equipment & applications

  • Replacement element for OEM hydraulic filter housings

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the SP-030-E-20-B filter element?
The published envelope is 49.5 mm OD × 207 mm length with a 23.9 mm inside diameter (1.949 × 8.150 in × 0.941 in ID). Confirm against the housing drawing before ordering.
What replaces the SP-030-E-20-B filter element?
20 partial match(es) requiring parameter review
How do I read the SP-030-E-20-B part number?
See the designation decoder above: each segment of SP030E20B encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Same-envelope elements from other brands

View full interchange →

These 15 catalog element(s) share the 50×207 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.

Other models in the Replacement Elements series

All 3832 →

Reviewed & verified by the ElementRef engineering desk against STAUFF on 2026-09-27. Read our editorial & correction policy.