STAUFF · Replacement Elements · inline line
SP-030-E-05-B filter element: specifications & equivalents
The SP-030-E-05-B is a STAUFF inline-line hydraulic filter element, sized 49.5 × 207 mm OD × length (ID 23.9 mm). Verify against the current manufacturer data sheet before ordering.
Micron rating, media type, collapse pressure and seal material are not printed in the STAUFF interchange listing and are pending extraction from STAUFF product data sheets. Verify against the current STAUFF catalog before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | inline line |
| Outside diameter OD | 49.5 mm |
| Inside diameter ID | 23.9 mm |
| Length | 207 mm |
| End caps | open-ended cartridge element |
| Integral bypass valve | none (housing/valve-dependent) |
| Source catalog | STAUFF: STAUFF Filter Interchange online database (filterinterchange.com) |
| Last verified | 2026-09-27 |
Sources: STAUFF — STAUFF Filter Interchange online database (filterinterchange.com) — accessed 2026-09-27.
STAUFF® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized STAUFF distributor.
Dimensions & series range
| Outside diameter | 49.5 mm (1.949 in) |
| Inside diameter | 23.9 mm (0.941 in) |
| Overall length | 207 mm (8.150 in) |
All 50×207 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
|
↔ 0009831601 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 0009831601 (LINDE) as replaced by SP-030-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 07993016 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 07993016 (BOMAG) as replaced by SP-030-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 11308D06BN page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 1.13.08D06BN (HYDAC) as replaced by SP-030-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 1455840 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 1455840 (OSHKOSH) as replaced by SP-030-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 930198Q page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 930198Q (PARKER) as replaced by SP-030-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 980086UM page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 980086UM (TRIBOGUARD) as replaced by SP-030-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ H980008006BN page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists H9800/08 006 BN (HYDAC) as replaced by SP-030-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HID5224 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists HID5224 (STEP FILTERS) as replaced by SP-030-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ P169798 page in verification queue | Donaldson | partial | STAUFF Filter Interchange lists P169798 (DONALDSON) as replaced by SP-030-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ WGPN9808 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists WGPN 9808 (WOODGATE) as replaced by SP-030-E-05-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the SP-030-E-05-B model number is decoded
- SP-030-E-05-BSTAUFF replacement element part number per the STAUFF Filter Interchange database.
Typical equipment & applications
- Replacement element for OEM hydraulic filter housings
Selection pitfalls — read before you substitute
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What are the dimensions of the SP-030-E-05-B filter element?
What replaces the SP-030-E-05-B filter element?
How do I read the SP-030-E-05-B part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Same-envelope elements from other brands
View full interchange →These 15 catalog element(s) share the 50×207 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.
Other models in the Replacement Elements series
All 3832 →Reviewed & verified by the ElementRef engineering desk against STAUFF on 2026-09-27. Read our editorial & correction policy.