STAUFF · Replacement Elements · inline line

SF-6610 filter element: specifications & equivalents

The SF-6610 is a STAUFF inline-line hydraulic filter element, sized 95 × 144 mm OD × length. Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 95 × 144 mm
Line type inline
Partially verified. Fit and grade trace to an official interchange document; dimensional values are compiled from 0 aftermarket listing(s) and must be confirmed against the manufacturer housing drawing. Confidence score 0.85.

Micron rating, media type, collapse pressure and seal material are not printed in the STAUFF interchange listing and are pending extraction from STAUFF product data sheets. Verify against the current STAUFF catalog before ordering.

Specification table

ParameterValue
Filter type inline line
Outside diameter OD 95 mm
Length 144 mm
Integral bypass valve none (housing/valve-dependent)
Source catalog STAUFF: STAUFF Filter Interchange online database (filterinterchange.com)
Last verified2026-09-27

Sources: STAUFF — STAUFF Filter Interchange online database (filterinterchange.com) — accessed 2026-09-27.

STAUFF® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized STAUFF distributor.

Dimensions & series range

Outside diameter95 mm (3.740 in)
Overall length144 mm (5.669 in)

All 95×144 mm interchange elements →

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ 137939C1
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 137939C1 (NAVISTAR) as replaced by SF-6610. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 3778119
page in verification queue
UFIpartialSTAUFF Filter Interchange lists 3778119 (CLARK) as replaced by SF-6610. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 70016
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 70016 (CIMTEK) as replaced by SF-6610. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 920130002
page in verification queue
AftermarketpartialSTAUFF Filter Interchange lists 920130002 (KALMAR) as replaced by SF-6610. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ 9800098
page in verification queue
UFIpartialSTAUFF Filter Interchange lists 9800098 (NEW HOLLAND) as replaced by SF-6610. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.
↔ P779584
page in verification queue
DonaldsonpartialSTAUFF Filter Interchange lists P779584 (DONALDSON) as replaced by SF-6610. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the SF-6610 model number is decoded

  • SF-6610STAUFF replacement element part number per the STAUFF Filter Interchange database.

Typical equipment & applications

  • Replacement element for OEM hydraulic filter housings

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the SF-6610 filter element?
The published envelope is 95 mm OD × 144 mm length (3.740 × 5.669 in). Confirm against the housing drawing before ordering.
What replaces the SF-6610 filter element?
6 partial match(es) requiring parameter review
How do I read the SF-6610 part number?
See the designation decoder above: each segment of SF6610 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.