STAUFF · Replacement Elements · inline line
SF-6520 filter element: specifications & equivalents
The SF-6520 is a STAUFF inline-line hydraulic filter element, sized 93.2 × 147 mm OD × length. Verify against the current manufacturer data sheet before ordering.
Micron rating, media type, collapse pressure and seal material are not printed in the STAUFF interchange listing and are pending extraction from STAUFF product data sheets. Verify against the current STAUFF catalog before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | inline line |
| Outside diameter OD | 93.2 mm |
| Length | 147 mm |
| Integral bypass valve | none (housing/valve-dependent) |
| Source catalog | STAUFF: STAUFF Filter Interchange online database (filterinterchange.com) |
| Last verified | 2026-09-27 |
Sources: STAUFF — STAUFF Filter Interchange online database (filterinterchange.com) — accessed 2026-09-27.
STAUFF® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized STAUFF distributor.
Dimensions & series range
| Outside diameter | 93.2 mm (3.669 in) |
| Overall length | 147 mm (5.787 in) |
All 93×147 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
|
↔ 1000000 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 1000000 (TELEDYNE) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 1551001 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 1551-001 (GRANIT) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 180595 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 180595 (HYSTER) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 20932 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 20932 (VERSATILE) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 239740 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 239740 (TORO) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 2683001 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 2683001 (VERMEER) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 5000824335 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 5000824335 (RENAULT) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 55740 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 55740 (TENNANT) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 7005001132 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 7005001132 (KUBOTA) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 70134 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 70134 (CIMTEK) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 8066000 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 8066000 (GRESEN) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 8066001 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 8066-001 (GRESEN) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 93220010 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 93220010 (FALK) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 980908 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 980908 (GROVE) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ AE33293 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists AE33293 (JOHN DEERE) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ BT83910 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists BT 839-10 (BALDWIN) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ FPE3010N page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists FPE 30-10N (FILTRATION SYST) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ K22001 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists K 22001 (GRESEN) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ RSE3010N page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists RSE30-10N (CANFLO) as replaced by SF-6520. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the SF-6520 model number is decoded
- SF-6520STAUFF replacement element part number per the STAUFF Filter Interchange database.
Typical equipment & applications
- Replacement element for OEM hydraulic filter housings
Selection pitfalls — read before you substitute
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What are the dimensions of the SF-6520 filter element?
What replaces the SF-6520 filter element?
How do I read the SF-6520 part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Same-envelope elements from other brands
View full interchange →These 3 catalog element(s) share the 93×147 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.
Other models in the Replacement Elements series
All 3832 →Reviewed & verified by the ElementRef engineering desk against STAUFF on 2026-09-27. Read our editorial & correction policy.