STAUFF · Replacement Elements · inline line
SE-035-G-20-B filter element: specifications & equivalents
The SE-035-G-20-B is a STAUFF inline-line hydraulic filter element, sized 47 × 193 mm OD × length (ID 22.2 mm). Verify against the current manufacturer data sheet before ordering.
Micron rating, media type, collapse pressure and seal material are not printed in the STAUFF interchange listing and are pending extraction from STAUFF product data sheets. Verify against the current STAUFF catalog before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | inline line |
| Outside diameter OD | 47 mm |
| Inside diameter ID | 22.2 mm |
| Length | 193 mm |
| End caps | open-ended cartridge element |
| Integral bypass valve | none (housing/valve-dependent) |
| Source catalog | STAUFF: STAUFF Filter Interchange online database (filterinterchange.com) |
| Last verified | 2026-09-27 |
Sources: STAUFF — STAUFF Filter Interchange online database (filterinterchange.com) — accessed 2026-09-27.
STAUFF® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized STAUFF distributor.
Dimensions & series range
| Outside diameter | 47 mm (1.850 in) |
| Inside diameter | 22.2 mm (0.874 in) |
| Overall length | 193 mm (7.598 in) |
All 47×193 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
|
↔ 01260883 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 01260883 (HYDAC) as replaced by SE-035-G-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 02055931 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 02055931 (HYDAC) as replaced by SE-035-G-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 1260883 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 1260883 (HYDAC) as replaced by SE-035-G-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 1268309 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 1268309 (HYDAC) as replaced by SE-035-G-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 2055931 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 2055931 (HYDAC) as replaced by SE-035-G-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 937066Q page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 937066Q (PARKER) as replaced by SE-035-G-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ H0140DN2016 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists H0140DN2016 (COMEX / Ecoparts) as replaced by SE-035-G-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HC2216FCT8H page in verification queue | Pall | partial | STAUFF Filter Interchange lists HC2216FCT8H (PALL) as replaced by SE-035-G-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HC2216FHT8H page in verification queue | Pall | partial | STAUFF Filter Interchange lists HC2216FHT8H (PALL) as replaced by SE-035-G-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HC2216FKT8H page in verification queue | Pall | partial | STAUFF Filter Interchange lists HC2216FKT8H (PALL) as replaced by SE-035-G-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HC2216FRT8H page in verification queue | Pall | partial | STAUFF Filter Interchange lists HC2216FRT8H (PALL) as replaced by SE-035-G-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HC2216FUT8H page in verification queue | Pall | partial | STAUFF Filter Interchange lists HC2216FUT8H (PALL) as replaced by SE-035-G-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HID11975 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists HID11975 (STEP FILTERS) as replaced by SE-035-G-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HY13056 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists HY 13056 (SF-FILTER) as replaced by SE-035-G-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ R928017176 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists R 928017176 (EPE / Bosch-Rexroth Filtration) as replaced by SE-035-G-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the SE-035-G-20-B model number is decoded
- SE-035-G-20-BSTAUFF replacement element part number per the STAUFF Filter Interchange database.
Typical equipment & applications
- Replacement element for OEM hydraulic filter housings
Selection pitfalls — read before you substitute
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What are the dimensions of the SE-035-G-20-B filter element?
What replaces the SE-035-G-20-B filter element?
How do I read the SE-035-G-20-B part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Same-envelope elements from other brands
View full interchange →These 10 catalog element(s) share the 47×193 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.
Other models in the Replacement Elements series
All 3832 →Reviewed & verified by the ElementRef engineering desk against STAUFF on 2026-09-27. Read our editorial & correction policy.