STAUFF · Replacement Elements · inline line
SE-008-H-20-B filter element: specifications & equivalents
The SE-008-H-20-B is a STAUFF inline-line hydraulic filter element, sized 35 × 94 mm OD × length (ID 12.2 mm). Verify against the current manufacturer data sheet before ordering.
Micron rating, media type, collapse pressure and seal material are not printed in the STAUFF interchange listing and are pending extraction from STAUFF product data sheets. Verify against the current STAUFF catalog before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | inline line |
| Outside diameter OD | 35 mm |
| Inside diameter ID | 12.2 mm |
| Length | 94 mm |
| End caps | open-ended cartridge element |
| Integral bypass valve | none (housing/valve-dependent) |
| Source catalog | STAUFF: STAUFF Filter Interchange online database (filterinterchange.com) |
| Last verified | 2026-09-28 |
Sources: STAUFF — STAUFF Filter Interchange online database (filterinterchange.com) — accessed 2026-09-27.
STAUFF® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized STAUFF distributor.
Dimensional drawing
Dimensions & series range
| Outside diameter | 35 mm (1.378 in) |
| Inside diameter | 12.2 mm (0.480 in) |
| Overall length | 94 mm (3.701 in) |
All 35×94 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
| ↔ 01.E 30.16VG.HR.E.P.- | Eaton / Internormen | partial | STAUFF Filter Interchange lists 01/E30/16VGHREP (INTERNORMEN) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ 01.E 30.25VG.HR.E.P.- | Eaton / Internormen | partial | STAUFF Filter Interchange lists 01.E 30.25VG.HR.E.P (INTERNORMEN) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ 0030 D 020 BH4HC | HYDAC | partial | STAUFF Filter Interchange lists 1263455 (HYDAC) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 300068 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 300068 (INTERNORMEN) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 58053 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 580.53 (FBO) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 77888514 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 77888514 (COMEX / Ecoparts) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 930H20XLF000P page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 9. 30 H20XL-F00-0-P (EPE / Bosch-Rexroth Filtration) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 930LAH20XLF000MSO3000 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 9.30LA H20XL-F00-0-M SO3000 (EPE / Bosch-Rexroth Filtration) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 930LAH20XLF000P page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 9. 30 LA H20XL-F00-0-P (EPE / Bosch-Rexroth Filtration) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 930LAH20XLF000PX page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 9. 30 LA H20XL-F00-0-PX (EPE / Bosch-Rexroth Filtration) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ BE30P25AH page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists BE30P25AH (BEHRINGER) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ BE30P25AHR page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists BE30P25AHR (BEHRINGER) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ DP010A020AHP01 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists DP010A020AHP01 (MP-FILTRI) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ H0030DH2016 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists H0030DH2016 (COMEX / Ecoparts) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HP03DHL425MB page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists HP03DHL4-25MB (HY-PRO) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HY13006 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists HY 13006 (SF-FILTER) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ PR3038 | Parker | partial | STAUFF Filter Interchange lists PR3038 (PARKER) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ PR3038Q | Parker | partial | STAUFF Filter Interchange lists PR3038Q (PARKER) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ SBF-0031D-Z25B | Schroeder Industries | partial | Schroeder online cross-reference (STAUFF); envelope match — verify grade and seals. |
|
↔ ST1033 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists ST1033 (ST-FILTER) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ STU608 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists STU-608 (NORMAN) as replaced by SE-008-H-20-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
Full chart: STAUFF cross reference chart →
How the SE-008-H-20-B model number is decoded
- SE-008-H-20-BSTAUFF replacement element part number per the STAUFF Filter Interchange database.
Typical equipment & applications
- Replacement element for OEM hydraulic filter housings
Selection pitfalls — read before you substitute
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What are the dimensions of the SE-008-H-20-B filter element?
What replaces the SE-008-H-20-B filter element?
Is a same-envelope aftermarket element always a drop-in replacement?
Same-envelope elements from other brands
View full interchange →These 46 catalog element(s) share the 35×94 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.
Other models in the Replacement Elements series
All 4930 (list page 7/10) →Reviewed & verified by the ElementRef engineering desk against STAUFF on 2026-09-28. Read our editorial & correction policy.