STAUFF · Replacement Elements · inline line
RP-080-E-10-B filter element: specifications & equivalents
The RP-080-E-10-B is a STAUFF inline-line hydraulic filter element, sized 96 × 323.5 mm OD × length (ID 43.5 mm). Verify against the current manufacturer data sheet before ordering.
Micron rating, media type, collapse pressure and seal material are not printed in the STAUFF interchange listing and are pending extraction from STAUFF product data sheets. Verify against the current STAUFF catalog before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | inline line |
| Outside diameter OD | 96 mm |
| Inside diameter ID | 43.5 mm |
| Length | 323.5 mm |
| Integral bypass valve | none (housing/valve-dependent) |
| Source catalog | STAUFF: STAUFF Filter Interchange online database (filterinterchange.com) |
| Last verified | 2026-09-28 |
Sources: STAUFF — STAUFF Filter Interchange online database (filterinterchange.com) — accessed 2026-09-27.
STAUFF® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized STAUFF distributor.
Dimensional drawing
Dimensions & series range
| Outside diameter | 96 mm (3.780 in) |
| Inside diameter | 43.5 mm (1.713 in) |
| Overall length | 323.5 mm (12.736 in) |
All 96×324 mm interchange elements →
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
| ↔ R452G10 | Filtrec | full | Filtrec's official Cross Navigator maps STAUFF RP080E10B to FILTREC R452G10 as a direct replacement, publishing the FILTREC element's OD/ID/height envelope and media grade. |
|
↔ 01269074 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 01269074 (HYDAC) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 02062322 page in verification queue | UFI | partial | STAUFF Filter Interchange lists 02062322 (HYDAC) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 05850010VG13 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 05/8500/10VG13 (INTERNORMEN) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 168500TH10SLS000P page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 16.8500TH10SLS000P (EPE / Bosch-Rexroth Filtration) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 168500TH10XLS000P page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 16.8500 / T H10XL-S00-0-P (EPE / Bosch-Rexroth Filtration) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 783543 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 783543 (BOHLER) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ 85001312UM page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists 85001312UM (TRIBOGUARD) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ 935177 | Parker | partial | STAUFF Filter Interchange lists 935177 (PARKER) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ BE85001312A page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists BE8500/13-12A (BEHRINGER) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ FC1372F010BS page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists FC1372F010BS (FINNFILTER) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ FC1372Q010BT page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists FC1372Q010BT (FINNFILTER) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ H850013010BN page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists H8500/13 010 BN (HYDAC) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ HC8500FUS13H page in verification queue | Pall | partial | STAUFF Filter Interchange lists HC 8500 FUS 13H (PALL) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ HF30287 | Fleetguard | partial | Fleetguard's online catalog lists RP080E10B as an interchange for HF30287. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ HP85L1312MB page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists HP85L1312MB (HY-PRO) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ P85100KFB page in verification queue | Donaldson | partial | STAUFF Filter Interchange lists P85100KFB (PTI-MAHLE / Filtration Group) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ PT23506-MPG | Baldwin Filters | partial | Baldwin's Form 561 Number-Finder cross-reference lists RP080E10B (STAUFF) as replaced by Baldwin PT23506-MPG. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ QH8500A12B13 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists QH8500A12B13 (QUALITY FILTRATION) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ R928016783 page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists R 928016783 (EPE / Bosch-Rexroth Filtration) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
|
↔ SBF850013S7B page in verification queue | Aftermarket | partial | STAUFF Filter Interchange lists SBF-8500-13S7B (SCHROEDER) as replaced by RP-080-E-10-B. Envelope dimensions are published; media grade and performance data are not — confirm before substituting in cleanliness-critical circuits. |
| ↔ SBF-8500-13Z10B | Schroeder Industries | partial | Schroeder online cross-reference (STAUFF); envelope match — verify grade and seals. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
Full chart: STAUFF cross reference chart →
How the RP-080-E-10-B model number is decoded
- RP-080-E-10-BSTAUFF replacement element part number per the STAUFF Filter Interchange database.
Typical equipment & applications
- Replacement element for OEM hydraulic filter housings
Frequently asked questions
What are the dimensions of the RP-080-E-10-B filter element?
What replaces the RP-080-E-10-B filter element?
Is a same-envelope aftermarket element always a drop-in replacement?
Same-envelope elements from other brands
View full interchange →These 7 catalog element(s) share the 96×324 mm envelope. Envelope match alone does not guarantee interchangeability — compare micron/Beta, seals and collapse rating.
Other models in the Replacement Elements series
All 4930 (list page 5/10) →Reviewed & verified by the ElementRef engineering desk against STAUFF on 2026-09-28. Read our editorial & correction policy.