Schroeder Industries · BestFit Elements · inline line

Element, 10 Micron, Sintered Bronze filter element: specifications & equivalents

The Element, 10 Micron, Sintered Bronze is a Schroeder Industries inline-line hydraulic filter element, built with metal mesh media media, rated at 10 µm class (β(c) ≥ 1000 (99.9% efficiency)). Verify against the current manufacturer data sheet before ordering.

Filtration rating 10 µm nom.
Beta rating β (c) ≥ 1000 (99.9% efficiency)
Media Metal Mesh Media
Collapse / burst 20.7 bar
Line type inline
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-28. Confidence score 0.90.

Dimensions, ratings and seal compound are taken from the Schroeder Industries online catalog. The nominal µm rating and the β200 absolute rating use different conventions — match the existing media grade before substituting; verify against the current Schroeder data sheet before ordering.

Specification table

ParameterValue
Filter type inline line
Media Metal Mesh Media
Filtration rating 10 µm
Rating basis nominal
Beta ratio β(c) ≥ 1000 (99.9% efficiency)
End caps open-ended cartridge element
Collapse / burst pressure 20.7 bar
Integral bypass valve none (housing/valve-dependent)
Seal material Nitrile (Buna-N)
Operating temperature -29 to 107 °C
Mass 450 g
Source catalog Schroeder Industries: Schroeder Industries online catalog (catalog.schroederindustries.com)
Last verified2026-09-28

Sources: Schroeder Industries — Schroeder Industries online catalog (catalog.schroederindustries.com) — accessed 2026-09-28.

Schroeder Industries® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Schroeder Industries distributor.

Cross references & equivalents

No catalog-verified cross references yet. This model is in the manual verification queue — request a verified equivalent.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the Element, 10 Micron, Sintered Bronze model number is decoded

  • Element, 10 Micron, Sintered BronzeSchroeder BestFit filter element part number of the Sintered Bronze housing-size family.
  • Metal Mesh MediaFilter media execution.
  • 10 µmNominal filter rating as printed in the Schroeder catalog.
  • β≥1000Absolute rating: β(c) ≥ 1000, 99.9% efficiency.
  • 20.7 barElement collapse pressure rating.
  • Nitrile (Buna-N)Seal compound.

Typical equipment & applications

  • Replacement element for Schroeder hydraulic and lube filter housings
  • Industrial and mobile hydraulic filtration

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What micron rating does Element, 10 Micron, Sintered Bronze use?
This element is rated 10 µm (nominal class) — β(c) ≥ 1000 (99.9% efficiency). Always compare Beta ratings at the same test point: two brands may print different micron numbers for the same physical grade.
What replaces the Element, 10 Micron, Sintered Bronze filter element?
Cross references are being verified for this model — use the inquiry form and the engineering desk will confirm equivalents.
How do I read the Element, 10 Micron, Sintered Bronze part number?
See the designation decoder above: each segment of ELEMENT10MICRONSINTEREDBRONZE encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the BestFit Elements series

All 1082 →

Reviewed & verified by the ElementRef engineering desk against Schroeder Industries on 2026-09-28. Read our editorial & correction policy.