MP Filtri · HP / CU / HPX Elements · pressure line

HP5003A10VNP01 filter element: specifications & equivalents

The HP5003A10VNP01 is a MP Filtri pressure-line hydraulic filter element, built with inorganic microfiber media, rated at 10 µm absolute. Verify against the current manufacturer data sheet before ordering.

Filtration rating 10 µm abs.
Media Inorganic microfiber
Collapse / burst 20 bar
Line type pressure
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-28. Confidence score 0.90.

Part number structure and orderable options are taken from the MP Filtri Hydraulic Filtration Catalogue (CAT_HF_HP_EN p.84). This is the FPM (Viton) seal / 20 bar collapse execution; it is a distinct orderable part number from the standard (NBR seal, 20 bar) element of the same series, length and media. Element dimensions are not available for this series. Verify against the current MP Filtri data sheet before ordering.

Specification table

ParameterValue
Filter type pressure line
Media Inorganic microfiber
Filtration rating 10 µm
Rating basis absolute
End caps open-ended cartridge element
Collapse / burst pressure 20 bar
Integral bypass valve none (housing/valve-dependent)
Seal material Fluorocarbon (FPM/Viton)
Source catalog MP Filtri: MP Filtri Hydraulic Filtration Catalogue
Last verified2026-09-28

Sources: MP Filtri — MP Filtri Hydraulic Filtration Catalogue — accessed 2026-09-29.

MP Filtri® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized MP Filtri distributor.

Cross references & equivalents

No catalog-verified cross references yet. This model is in the manual verification queue — request a verified equivalent.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

Full chart: MP Filtri cross reference chart →

How the HP5003A10VNP01 model number is decoded

  • HP500MP Filtri element series and size code for the matched high/medium-pressure housing family.
  • 3Element length code within the series.
  • A10Filter media: Inorganic microfiber, 10 µm (absolute rating per ISO 16889).
  • VSeals: FPM (fluorocarbon/Viton).
  • NElement differential-pressure (collapse) rating: 20 bar standard execution.
  • P01MP Filtri standard catalogue item execution.

Typical equipment & applications

  • Pressure-line hydraulic filters upstream of control valves
  • High-differential-pressure industrial hydraulic circuits
  • Hydraulic power units for steel, paper and power generation

Selection pitfalls — read before you substitute

  • Line type is not interchangeable: return-line cartridges are low-collapse executions that typically tolerate roughly 10–20 bar differential, while pressure-line elements are commonly rated 100–210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • This execution uses fluorocarbon (fpm/viton) seals — verify the compound against the fluid data sheet: standard nitrile (NBR) can fail early in phosphate-ester fluids and at sustained high temperature, where fluorocarbon/Viton executions may be required.
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What micron rating does HP5003A10VNP01 use?
This element is rated 10 µm absolute. Always compare Beta ratings at the same test point: two brands may print different micron numbers for the same physical grade.
What replaces the HP5003A10VNP01 filter element?
Cross references are being verified for this model — use the inquiry form and the engineering desk will confirm equivalents.
How do I read the HP5003A10VNP01 part number?
See the designation decoder above: each segment of HP5003A10VNP01 encodes size, line type, filtration grade and media/collapse execution.
How often should a hydraulic filter element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the HP / CU / HPX Elements series

All 522 (list page 1/2) →

Reviewed & verified by the ElementRef engineering desk against MP Filtri on 2026-09-28. Read our editorial & correction policy.