MP Filtri · HP / CU / HPX Elements · return line
CU1102A03ANP01 filter element: specifications & equivalents
The CU1102A03ANP01 is a MP Filtri return-line hydraulic filter element, built with inorganic microfiber media, rated at 3 µm absolute. Verify against the current manufacturer data sheet before ordering.
Part number structure and orderable options are taken from the MP Filtri Hydraulic Filtration Catalogue (CAT_HF_EN p.297). This is the standard execution; FPM seals (V) and high-collapse variants (S/H) are orderable under different suffixes. Element dimensions are not available for this series — verify against the current MP Filtri data sheet before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | return line |
| Media | Inorganic microfiber |
| Filtration rating | 3 µm |
| Rating basis | absolute |
| End caps | open-ended cartridge element |
| Collapse / burst pressure | 20 bar |
| Integral bypass valve | none (housing/valve-dependent) |
| Seal material | Nitrile (Buna-N) |
| Source catalog | MP Filtri: MP Filtri Hydraulic Filtration Catalogue |
| Last verified | 2026-09-28 |
Sources: MP Filtri — MP Filtri Hydraulic Filtration Catalogue — accessed 2026-09-29.
MP Filtri® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized MP Filtri distributor.
Cross references & equivalents
No catalog-verified cross references yet. This model is in the manual verification queue — request a verified equivalent.
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the CU1102A03ANP01 model number is decoded
- CU110MP Filtri element series and size code for the matched return-line housing family.
- 2Element length code within the series.
- A03Filter media: Inorganic microfiber, 3 µm (absolute rating per ISO 16889).
- ASeals: NBR (nitrile).
- NElement differential-pressure (collapse) rating: 20 bar standard execution.
- P01MP Filtri standard catalogue item execution.
Typical equipment & applications
- Tank-mounted return-line hydraulic filters
- Hydraulic power units and lubrication systems
- Construction and agricultural machinery
- Machine tool and industrial hydraulic systems
Selection pitfalls — read before you substitute
- A return-line element is not a pressure-line element: return cartridges (BN4HC low-collapse) tolerate roughly 20 bar differential, while BH4HC pressure executions are rated to 210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
- This element has no integral bypass — opening pressure is set by the housing’s reusable bypass valve. Confirm the valve setting (commonly 3.4 bar) is present before fitting.
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- Fine 3 µm media loads faster and runs at a higher cold Δp than coarser grades — only downgrade cleanliness targets if the system ISO 4406 code allows it.
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What micron rating does CU1102A03ANP01 use?
What replaces the CU1102A03ANP01 filter element?
How do I read the CU1102A03ANP01 part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Other models in the HP / CU / HPX Elements series
All 435 →Reviewed & verified by the ElementRef engineering desk against MP Filtri on 2026-09-28. Read our editorial & correction policy.