Fleetguard · HF Hydraulic · return line

HF6123 filter element: specifications & equivalents

The HF6123 is a Fleetguard return-line hydraulic filter element, sized 93.22 × 136.14 mm OD × length, rated at 26 µm class (TWA 26 µm at β=2 per ISO 16889). Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 93.22 × 136.14 mm
Filtration rating 26 µm nom.
Beta rating TWA 26 µm at β=2 per ISO 16889
Thread 1.00 1/8-16 UN-2B
Line type return
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-28. Confidence score 0.90.

Specifications and cross-references are taken from the Fleetguard online catalog API. Where both TWA and Beta ratings are published the conventions differ — verify cleanliness targets, collapse rating and seal configuration against the current Fleetguard data sheet before ordering.

Specification table

ParameterValue
Filter type return line
Filtration rating 26 µm
Rating basis nominal
Beta ratio TWA 26 µm at β=2 per ISO 16889
Outside diameter OD 93.22 mm
Length 136.14 mm
Thread / connection 1.00 1/8-16 UN-2B
End caps spin-on baseplate with attached gasket
Flow direction outside-in
Integral bypass valve none (housing/valve-dependent)
Manufacturer part no. HF6123
Source catalog Cummins Filtration / Fleetguard: Fleetguard online product catalog (fleetguard.com)
Last verified2026-09-28

Sources: Cummins Filtration / Fleetguard — Fleetguard online product catalog (fleetguard.com) — accessed 2026-09-28.

Fleetguard® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Fleetguard distributor.

Dimensions & series range

Outside diameter93.22 mm (3.670 in)
Overall length136.14 mm (5.360 in)

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ 25012480
page in verification queue
UFIpartialFleetguard's online catalog lists 25012480 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ 3437036M1
page in verification queue
AftermarketpartialFleetguard's online catalog lists 3437036M1 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ 3912298
page in verification queue
UFIpartialFleetguard's online catalog lists 3912298 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ 51712WIX FilterspartialFleetguard's online catalog lists 51712 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ 76532
page in verification queue
AftermarketpartialFleetguard's online catalog lists 76532 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ 83912298
page in verification queue
UFIpartialFleetguard's online catalog lists 83912298 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ 84401812
page in verification queue
UFIpartialFleetguard's online catalog lists 84401812 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ 89FB9155AA
page in verification queue
AftermarketpartialFleetguard's online catalog lists 89FB9155AA as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ 9314
page in verification queue
AftermarketpartialFleetguard's online catalog lists 9314 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ 950SH
page in verification queue
AftermarketpartialFleetguard's online catalog lists 950SH as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ BC1168
page in verification queue
AftermarketpartialFleetguard's online catalog lists BC1168 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ BT354
page in verification queue
AftermarketpartialFleetguard's online catalog lists BT354 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ C120
page in verification queue
AftermarketpartialFleetguard's online catalog lists C120 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ C1901
page in verification queue
AftermarketpartialFleetguard's online catalog lists C1901 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ CS1440H1
page in verification queue
AftermarketpartialFleetguard's online catalog lists CS1440H1 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ D10016780
page in verification queue
AftermarketpartialFleetguard's online catalog lists D10016780 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ D4NNB486A
page in verification queue
AftermarketpartialFleetguard's online catalog lists D4NNB486A as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ D4NNB486B
page in verification queue
AftermarketpartialFleetguard's online catalog lists D4NNB486B as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ D4NNB486D
page in verification queue
AftermarketpartialFleetguard's online catalog lists D4NNB486D as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ D8NNB486AA
page in verification queue
AftermarketpartialFleetguard's online catalog lists D8NNB486AA as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ D8NNB486EA
page in verification queue
AftermarketpartialFleetguard's online catalog lists D8NNB486EA as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ FJX2051
page in verification queue
AftermarketpartialFleetguard's online catalog lists FJX2051 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ GP166
page in verification queue
AftermarketpartialFleetguard's online catalog lists GP166 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ H27W01
page in verification queue
AftermarketpartialFleetguard's online catalog lists H27W01 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HF0612300
page in verification queue
FleetguardpartialFleetguard's online catalog lists HF0612300 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HF0612300J
page in verification queue
FleetguardpartialFleetguard's online catalog lists HF0612300 J as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HF0612300JX
page in verification queue
FleetguardpartialFleetguard's online catalog lists HF0612300JX as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HSM6101
page in verification queue
AftermarketpartialFleetguard's online catalog lists HSM6101 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HSM6174
page in verification queue
AftermarketpartialFleetguard's online catalog lists HSM6174 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ L1712
page in verification queue
AftermarketpartialFleetguard's online catalog lists L1712 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ P3952
page in verification queue
DonaldsonpartialFleetguard's online catalog lists P3952 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ P4638
page in verification queue
DonaldsonpartialFleetguard's online catalog lists P4638 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ P551323
page in verification queue
DonaldsonpartialFleetguard's online catalog lists P551323 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ P779587
page in verification queue
DonaldsonpartialFleetguard's online catalog lists P779587 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ PERI248
page in verification queue
AftermarketpartialFleetguard's online catalog lists PERI248 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ PF2051
page in verification queue
AftermarketpartialFleetguard's online catalog lists PF2051 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ SBA340500900
page in verification queue
AftermarketpartialFleetguard's online catalog lists SBA340500900 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ SBA34501020
page in verification queue
AftermarketpartialFleetguard's online catalog lists SBA34501020 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ SH59314
page in verification queue
AftermarketpartialFleetguard's online catalog lists SH59314 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ SP866
page in verification queue
AftermarketpartialFleetguard's online catalog lists SP866 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ VPD5021
page in verification queue
AftermarketpartialFleetguard's online catalog lists VPD5021 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ VPK1562
page in verification queue
AftermarketpartialFleetguard's online catalog lists VPK1562 as an interchange for HF6123. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the HF6123 model number is decoded

  • HF6123Fleetguard HF-series hydraulic spin-on filter part number.
  • 136.14 mmOverall height.
  • 93.22 mmLargest outside diameter.
  • 1.00 1/8-16 UN-2BSpin-on mounting thread.
  • TWA 26 µm at β=2 per ISO 16889Published efficiency ratings.

Typical equipment & applications

  • Construction, agricultural and industrial hydraulic circuits
  • Mobile-equipment hydraulic return and pressure lines

Selection pitfalls — read before you substitute

  • A return-line element is not a pressure-line element: return cartridges (BN4HC low-collapse) tolerate roughly 20 bar differential, while BH4HC pressure executions are rated to 210 bar. Installing a low-collapse element in a pressure housing can rupture the media on cold-start spikes.
  • This element has no integral bypass — opening pressure is set by the housing’s reusable bypass valve. Confirm the valve setting (commonly 3.4 bar) is present before fitting.
  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the HF6123 filter element?
The published envelope is 93.22 mm OD × 136.14 mm length (3.670 × 5.360 in). Confirm against the housing drawing before ordering.
What micron rating does HF6123 use?
This element is rated 26 µm (nominal class) — TWA 26 µm at β=2 per ISO 16889. Always compare Beta ratings at the same test point: two brands may print different micron numbers for the same physical grade.
What replaces the HF6123 filter element?
42 partial match(es) requiring parameter review
How do I read the HF6123 part number?
See the designation decoder above: each segment of HF6123 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the HF Hydraulic series

All 2621 →

Reviewed & verified by the ElementRef engineering desk against Cummins Filtration / Fleetguard on 2026-09-28. Read our editorial & correction policy.