Eaton / Internormen · 01.E / 01.N / Easy-Fit · pressure line

V0211B2W10 filter element: specifications & equivalents

The V0211B2W10 is a Eaton / Internormen pressure-line hydraulic filter element, built with water removing (w) media, sized 127 × 279.4 mm OD × length. Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 127 × 279.4 mm
Media Water removing (W)
Collapse / burst 10 bar
Line type pressure
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-28. Confidence score 0.90.

Specs come from Eaton's product data hub via its site-search API. The µm retention rating follows ISO 16889 (absolute convention), while the model-code fineness grade is nominal — match both before substituting.

Specification table

ParameterValue
Filter type pressure line
Media Water removing (W)
Outside diameter OD 127 mm
Length 279.4 mm
End caps open-ended cartridge element
Collapse / burst pressure 10 bar
Integral bypass valve none (housing/valve-dependent)
Seal material Nitrile (Buna-N)
Manufacturer part no. V0211B2W10
Source catalog Eaton: Eaton product data hub via site search API (eaton.com)
Last verified2026-09-28

Sources: Eaton — Eaton product data hub via site search API (eaton.com) — accessed 2026-09-29.

Eaton / Internormen® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Eaton / Internormen distributor.

Dimensions & series range

Outside diameter127 mm (5.000 in)
Overall length279.4 mm (11.000 in)

Cross references & equivalents

No catalog-verified cross references yet. This model is in the manual verification queue — request a verified equivalent.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the V0211B2W10 model number is decoded

  • V0211B2W10Eaton V021 Vickers filter element model code (Eaton V021 Vickers Pressure Filter Element).
  • V0211B2W10Eaton catalog number (order code) for the same element.
  • W10Filter fineness grade: nominal rating and media letter.
  • Water removing (W)Filter media execution.
  • 10 barDelta-P resistance class — maximum differential pressure (collapse) rating.
  • Nitrile (Buna-N)Seal compound.
  • 127 mmOuter diameter.
  • 279.4 mmElement height.

Typical equipment & applications

  • Pressure-line hydraulic filters upstream of control valves
  • High-differential-pressure industrial hydraulic circuits
  • Hydraulic power units for steel, paper and power generation

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the V0211B2W10 filter element?
The published envelope is 127 mm OD × 279.4 mm length (5.000 × 11.000 in). Confirm against the housing drawing before ordering.
What replaces the V0211B2W10 filter element?
Cross references are being verified for this model — use the inquiry form and the engineering desk will confirm equivalents.
How do I read the V0211B2W10 part number?
See the designation decoder above: each segment of V0211B2W10 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the 01.E / 01.N / Easy-Fit series

All 3329 →