Baldwin Filters · Form 561 Interchange · inline line

H9123 filter element: specifications & equivalents

The H9123 is a Baldwin Filters inline-line hydraulic filter element. Verify against the current manufacturer data sheet before ordering.

Line type inline
Partially verified. Fit and grade trace to an official interchange document; dimensional values are compiled from 0 aftermarket listing(s) and must be confirmed against the manufacturer housing drawing. Confidence score 0.80.

Form 561 is a cross-reference only — Baldwin prints no dimensions, micron rating, collapse pressure or seal data for this part number here. Verify every specification against the current Baldwin data sheet before ordering.

Specification table

ParameterValue
Filter type inline line
Integral bypass valve none (housing/valve-dependent)
Manufacturer part no. H9123
Source catalog Baldwin Filters: Baldwin Filters Form 561
Last verified2026-09-30

Sources: Baldwin Filters — Baldwin Filters Form 561 — accessed 2026-09-30.

Baldwin Filters® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Baldwin Filters distributor.

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ 557801
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists 557801 (WIX) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 57801WIX FilterspartialBaldwin's Form 561 Number-Finder cross-reference lists 57801 (WIX) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 5839HF30112
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists 5839HF30112 (MACK) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 7801
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists 7801 (NAPA GOLD) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 9830622325
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists 9830622325 (MCNEILUS) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ ASHF975
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists ASHF975 (HA) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ AT84801
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists AT 84801 (CARQUEST) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ CD193G06AV
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists CD193G06AV (FILTREC) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ EL755921
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists EL755921 (HEIL) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ GHF30112
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists GHF30112 (FLEETGUARD) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ GHF7130
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists GHF7130 (FLEETGUARD) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ H880016005BN
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists H880016005BN (HYCON) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HC8800FDN16H
page in verification queue
PallpartialBaldwin's Form 561 Number-Finder cross-reference lists HC8800FDN16H (PALL) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HC8800FKN16H
page in verification queue
PallpartialBaldwin's Form 561 Number-Finder cross-reference lists HC8800FKN16H (PALL) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HC8800FUN16H
page in verification queue
PallpartialBaldwin's Form 561 Number-Finder cross-reference lists HC8800FUN16H (PALL) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HF30112FleetguardpartialFleetguard's online catalog lists H9123 as an interchange for HF30112. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HFR830112
page in verification queue
FleetguardpartialBaldwin's Form 561 Number-Finder cross-reference lists HFR830112 (FLEETRITE) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HH9123
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists HH9123 (HASTINGS PREMIUM) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ LH5006
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists LH5006 (LUBER-FINER) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ NG4ZUC2
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists NG4ZUC2 (GRAINGER) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ NHMC8800FKN16H
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists NHMC8800FKN16H (PALL) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ NP170481
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists NP170481 (DONALDSON) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ RHFR87130
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists RHFR87130 (FL) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ RQ8800EAL062N3
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists RQ8800EAL062N3 (PUROLATOR-FACET) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ SBF880016S3B
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists SBF880016S3B (SCHROEDER) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ T91801
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists T91801 (BIG A FILTER) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ V401857
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists V401857 (TER) as replaced by Baldwin H9123. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the H9123 model number is decoded

  • H9123Baldwin filter part number per the Form 561 Number-Finder cross-reference.

Typical equipment & applications

  • Hydraulic / transmission filtration — listed in the Baldwin Form 561 Number-Finder cross-reference.

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What replaces the H9123 filter element?
27 partial match(es) requiring parameter review
How do I read the H9123 part number?
See the designation decoder above: each segment of H9123 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the Form 561 Interchange series

All 1208 →

Reviewed & verified by the ElementRef engineering desk against Baldwin Filters on 2026-09-30. Read our editorial & correction policy.