Baldwin Filters · Form 561 Interchange · inline line

H9081 filter element: specifications & equivalents

The H9081 is a Baldwin Filters inline-line hydraulic filter element. Verify against the current manufacturer data sheet before ordering.

Line type inline
Partially verified. Fit and grade trace to an official interchange document; dimensional values are compiled from 0 aftermarket listing(s) and must be confirmed against the manufacturer housing drawing. Confidence score 0.80.

Form 561 is a cross-reference only — Baldwin prints no dimensions, micron rating, collapse pressure or seal data for this part number here. Verify every specification against the current Baldwin data sheet before ordering.

Specification table

ParameterValue
Filter type inline line
Integral bypass valve none (housing/valve-dependent)
Manufacturer part no. H9081
Source catalog Baldwin Filters: Baldwin Filters Form 561
Last verified2026-09-30

Sources: Baldwin Filters — Baldwin Filters Form 561 — accessed 2026-09-30.

Baldwin Filters® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Baldwin Filters distributor.

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ 23018849
page in verification queue
UFIpartialBaldwin's Form 561 Number-Finder cross-reference lists 23018849 (GENERAL MOTORS CORP.) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 4ZPW4
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists 4ZPW4 (GRAINGER) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 9314798
page in verification queue
UFIpartialBaldwin's Form 561 Number-Finder cross-reference lists 9314798 (PUROLATOR) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 9600EAL032F3
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists 9600EAL032F3 (PUROLATOR-FACET) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ A6010041
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists A6010041 (MPF) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ ALHC9600FDN13Z
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists ALHC9600FDN13Z (PALL) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ ALHC9600FKP13Z
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists ALHC9600FKP13Z (PALL) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ AUSP090E03B
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists AUSP090E03B (STAUFF) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ AUSP090E03V
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists AUSP090E03V (STAUFF) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ AUSP090E05V
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists AUSP090E05V (STAUFF) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ CE313FDPEV
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists CE313FDPEV (PUROLATOR) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ DG01980
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists DG01980 (PARKER) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ E6020B3U03
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists E6020B3U03 (WESTERN FILTER) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ E6020V3U03
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists E6020V3U03 (WESTERN FILTER) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ E926718
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists E926718 (PARR FILTERS) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ EAGO1981
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists EAGO1981 (PARKER) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ EAGO1982
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists EAGO1982 (PARKER) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ EYHF9803FT11
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists EYHF9803FT11 (GRE) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ FLH95091V
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists FLH95091V (LU) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ GHF7072F
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists GHF7072F (FLEETGUARD) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ GHF7473
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists GHF7473 (FL) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ GHF8273
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists GHF8273 (FLEETGUARD) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ H3050GFB
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists H3050GFB (PT) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ H3050GFV
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists H3050GFV (PT) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ H960013003BN
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists H960013003BN (HYCON) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HC9600FDP13Z
page in verification queue
PallpartialBaldwin's Form 561 Number-Finder cross-reference lists HC9600FDP13Z (PALL) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HC9600FUN13Z
page in verification queue
PallpartialBaldwin's Form 561 Number-Finder cross-reference lists HC9600FUN13Z (PALL) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HC9600FUP13Z
page in verification queue
PallpartialBaldwin's Form 561 Number-Finder cross-reference lists HC9600FUP13Z (PALL) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HF30525FleetguardpartialFleetguard's online catalog lists H9081 as an interchange for HF30525. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HF7472FleetguardpartialFleetguard's online catalog lists H9081 as an interchange for HF7472. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HFR830525
page in verification queue
FleetguardpartialBaldwin's Form 561 Number-Finder cross-reference lists HFR830525 (FLEETRITE) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HFR88273
page in verification queue
FleetguardpartialBaldwin's Form 561 Number-Finder cross-reference lists HFR88273 (FLEETRITE) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ IB9600EAL062F3
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists IB9600EAL062F3 (PUROLATOR-FACET) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ K92689
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists K92689 (AM) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ LGHF30525
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists LGHF30525 (FLEETGUARD) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ LRHFR87473
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists LRHFR87473 (FLEETRITE) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ MCH803FC11
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists MCH803FC11 (MPF) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ MP9600BDL032F3
page in verification queue
MP FiltripartialBaldwin's Form 561 Number-Finder cross-reference lists MP9600BDL032F3 (PFA) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ NFFPAVL170073ABS
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists NFFPAVL170073ABS (FINN FILTER) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ NP164602
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists NP164602 (DO) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ NP565188
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists NP565188 (DONALDSON) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ NP566215
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists NP566215 (DONALDSON) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ OH960013003BNV
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists OH960013003BNV (HYCON) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ OWGPP9613Z
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists O WGPP9613Z (WOO) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ PASP090003E
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists PASP090003E (STAUFF) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ R92692
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists R92692 (AM) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ RHFR87072F
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists RHFR87072F (FL) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ RQ96492
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists RQ96492 (CARQUEST) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ RSBF96001381B
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists RSBF96001381B (SCHROEDER) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ SBF96001381V
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists SBF96001381V (SCHROEDER) as replaced by Baldwin H9081. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the H9081 model number is decoded

  • H9081Baldwin filter part number per the Form 561 Number-Finder cross-reference.

Typical equipment & applications

  • Hydraulic / transmission filtration — listed in the Baldwin Form 561 Number-Finder cross-reference.

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What replaces the H9081 filter element?
50 partial match(es) requiring parameter review
How do I read the H9081 part number?
See the designation decoder above: each segment of H9081 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the Form 561 Interchange series

All 1208 →

Reviewed & verified by the ElementRef engineering desk against Baldwin Filters on 2026-09-30. Read our editorial & correction policy.