Baldwin Filters · Form 561 Interchange · inline line

H9050 filter element: specifications & equivalents

The H9050 is a Baldwin Filters inline-line hydraulic filter element. Verify against the current manufacturer data sheet before ordering.

Line type inline
Partially verified. Fit and grade trace to an official interchange document; dimensional values are compiled from 0 aftermarket listing(s) and must be confirmed against the manufacturer housing drawing. Confidence score 0.80.

Form 561 is a cross-reference only — Baldwin prints no dimensions, micron rating, collapse pressure or seal data for this part number here. Verify every specification against the current Baldwin data sheet before ordering.

Specification table

ParameterValue
Filter type inline line
Integral bypass valve none (housing/valve-dependent)
Manufacturer part no. H9050
Source catalog Baldwin Filters: Baldwin Filters Form 561
Last verified2026-09-30

Sources: Baldwin Filters — Baldwin Filters Form 561 — accessed 2026-09-30.

Baldwin Filters® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Baldwin Filters distributor.

Cross references & equivalents

Equivalent modelBrandMatch levelNote
↔ 10704D03BHV
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists 10704D03BHV (HYDAC) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 87836N
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists 87836N (NELSON-WINSLOW) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 902142UMV
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists 902142UMV (TRIBOGUARD) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 927725
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists 927725 (PARKER) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ 927725QParkerpartialBaldwin's Form 561 Number-Finder cross-reference lists 927725Q (PARKER) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ A1400EAH034F1
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists A1400EAH034F1 (PUROLATOR-FACET) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ A6008001
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists A6008001 (MPF) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ A943617Q
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists A943617Q (PARKER) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ AFKOVL913KPV
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists AFKOVL913KPV (AIRFIL) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ ALHC9021FUP4Z
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists ALHC9021FUP4Z (PA) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ ASHF7448
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists AS HF7448 (FL) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ B7160300
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists B7160300 (MOOG) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ B7160300A
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists B7160300A (MOOG) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ BE9021403AV
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists BE9021403AV (BEHRINGER FLUID) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ CF90208K6V
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists CF90208K6V (FILTERMART) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ CH9204MAVH
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists CH9204MAVH (FILTERSOFT) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ DD111G03BV
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists DD111G03BV (FILTREC) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ DT902145UM
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists DT902145UM (DONALDSON) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ EHP21L43M
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists EHP21L43M (HYDRECO) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ F90214K3V
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists F90214K3V (FILTERMART) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ FIMP3801
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists FIMP3801 (MPF) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ FISP020E10B
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists FI SP020E10B (STA) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ FISP020E10V
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists FISP020E10V (STA) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ FK010GUB
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists FK010GUB (PT) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ FK010GUV
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists FK010GUV (PT) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ G01429
page in verification queue
ParkerpartialBaldwin's Form 561 Number-Finder cross-reference lists G01429 (PARKER) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ G01433
page in verification queue
ParkerpartialBaldwin's Form 561 Number-Finder cross-reference lists G01433 (PARKER) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ G3902SGCV04
page in verification queue
ParkerpartialBaldwin's Form 561 Number-Finder cross-reference lists G3902SGCV04 (SET) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ G4ZHL7
page in verification queue
ParkerpartialBaldwin's Form 561 Number-Finder cross-reference lists G4ZHL7 (GRAINGER) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ GCH152FT21
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists GCH152FT21 (MOD) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ GHF7048F
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists GHF7048F (FLEETGUARD) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ H90214003BH
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists H90214003BH (HYCON) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ H90214003BHV
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists H90214003BHV (HYCON) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ H90214003BN
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists H90214003BN (HYCON) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HC9021FDP4ZPallpartialBaldwin's Form 561 Number-Finder cross-reference lists HC9021FDP4Z (PA) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HC9021FKP4Z
page in verification queue
PallpartialBaldwin's Form 561 Number-Finder cross-reference lists HC9021FKP4Z (PA) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HF30426FleetguardpartialFleetguard's online catalog lists H9050 as an interchange for HF30426. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting.
↔ HF30426FleetguardpartialBaldwin's Form 561 Number-Finder cross-reference lists HF30426 (FL) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HL8902H02V04
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists HL8902H02V04 (SEPARATION) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HP21L42MV
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists HP21L42MV (HY-PRO) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ HP21L43M
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists HP21L43M (HY-PRO) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ LRHFR87448
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists LRHFR87448 (FLEETRITE) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ MP925664
page in verification queue
MP FiltripartialBaldwin's Form 561 Number-Finder cross-reference lists MP925664 (PARR FILTERS) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ NE3042BU03
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists NE3042BU03 (WESTERN FILTER) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ NE3042VU03
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists NE3042VU03 (WESTERN FILTER) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ NP566335
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists NP566335 (DO) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ OWGPP92104Z
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists O WGPP92104Z (WOO) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ P167180DonaldsonpartialBaldwin's Form 561 Number-Finder cross-reference lists P167180 (DONALDSON) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ P7817802
page in verification queue
DonaldsonpartialBaldwin's Form 561 Number-Finder cross-reference lists P7817802 (MAHLE) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ PSP010003F
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists P SP010003F (STA) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ QH9021A03VO4
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists QH9021A03VO4 (QUALITY) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ R2062934
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists R2062934 (HYDAC) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ R921Z0403A
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists R921Z0403A (FAIREY-ARLON) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ RHFR87048F
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists RHFR87048F (FL) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ RK933576Q
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists RK933576Q (PARR FILTERS) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ RQ94306
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists RQ94306 (CARQUEST) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ RSBF90214Z3V
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists RSBF90214Z3V (SCHROEDER) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ SBF90214S1V
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists SBF90214S1V (SCHROEDER) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ SLH95023V
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists SLH95023V (LU) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ TB645641V
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists TB645641V (MOOG) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ UC7261
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists UC7261 (FRAM) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ V3045V1H03Eaton / InternormenpartialBaldwin's Form 561 Number-Finder cross-reference lists V3045V1H03 (VICKERS) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ VA9314349
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists VA9314349 (PU) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ XE9314352
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists XE9314352 (PU) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.
↔ XE932613Q
page in verification queue
AftermarketpartialBaldwin's Form 561 Number-Finder cross-reference lists XE932613Q (PARKER) as replaced by Baldwin H9050. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the H9050 model number is decoded

  • H9050Baldwin filter part number per the Form 561 Number-Finder cross-reference.

Typical equipment & applications

  • Hydraulic / transmission filtration — listed in the Baldwin Form 561 Number-Finder cross-reference.

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What replaces the H9050 filter element?
65 partial match(es) requiring parameter review
How do I read the H9050 part number?
See the designation decoder above: each segment of H9050 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the Form 561 Interchange series

All 1208 →

Reviewed & verified by the ElementRef engineering desk against Baldwin Filters on 2026-09-30. Read our editorial & correction policy.