Baldwin Filters · Form 561 Interchange · inline line
H9043 filter element: specifications & equivalents
The H9043 is a Baldwin Filters inline-line hydraulic filter element. Verify against the current manufacturer data sheet before ordering.
Form 561 is a cross-reference only — Baldwin prints no dimensions, micron rating, collapse pressure or seal data for this part number here. Verify every specification against the current Baldwin data sheet before ordering.
Specification table
| Parameter | Value |
|---|---|
| Filter type | inline line |
| Integral bypass valve | none (housing/valve-dependent) |
| Manufacturer part no. | H9043 |
| Source catalog | Baldwin Filters: Baldwin Filters Form 561 |
| Last verified | 2026-09-30 |
Sources: Baldwin Filters — Baldwin Filters Form 561 — accessed 2026-09-30.
Baldwin Filters® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized Baldwin Filters distributor.
Cross references & equivalents
| Equivalent model | Brand | Match level | Note |
|---|---|---|---|
|
↔ A6007005 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists A6007005 (M.P. PRODUCTS) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ B7160311 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists B7160311 (MOOG) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ G4ZHL2 page in verification queue | Parker | partial | Baldwin's Form 561 Number-Finder cross-reference lists G4ZHL2 (GRAINGER) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ GA9326799 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists GA9326799 (PUROLATOR) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ GHF7042 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists GHF7042 (FLEETGUARD) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ GHF9152FD11 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists GHF9152FD11 (GRE) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
| ↔ HC9020FKS4H | Pall | partial | Baldwin's Form 561 Number-Finder cross-reference lists HC9020FKS4H (PA) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
| ↔ HD55 | MANN-FILTER | partial | MANN-FILTER's online catalog lists H9043 (BALDWIN) as a comparison number for HD55. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting. |
| ↔ HF30199 | Fleetguard | partial | Fleetguard's online catalog lists H9043 as an interchange for HF30199. Envelope cross-reference; verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ LHC9020FDS4H page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists LHC9020FDS4H (PA) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ LHC9020FUS4H page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists LHC9020FUS4H (PA) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ M1400EAM122N1 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists M1400EAM122N1 (PFA) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ MP96481 page in verification queue | MP Filtri | partial | Baldwin's Form 561 Number-Finder cross-reference lists MP96481 (CARQUEST) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ NP165006 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists NP165006 (DO) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ OO34635085 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists OO34635085 (BLOUNT) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ OWGPS9204 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists O WGPS9204 (WOO) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ P0180443S61 page in verification queue | Donaldson | partial | Baldwin's Form 561 Number-Finder cross-reference lists P0180443S61 (FLUITEK) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ R920Z0412A page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists R920Z0412A (FAIREY-ARLON) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ RD2120136 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists RD2120136 (JLG INDUSTRIES INC.) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ RHFR830199 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists RHFR830199 (FLEETRITE) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ RHFR830200 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists RHFR830200 (FLEETRITE) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ RHFR87042 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists RHFR87042 (FL) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ SLPD204B12 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists SLPD204B12 (DIAGNETICS) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ TP3I0647 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists TP3I0647 (CATERPILLAR) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ UFLH4247 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists UFLH4247 (LUBER-FINER) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ V3041B1C10 page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists V3041B1C10 (VICKERS) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
|
↔ XRR920Z0415A page in verification queue | Aftermarket | partial | Baldwin's Form 561 Number-Finder cross-reference lists XRR920Z0415A (FAIREY-ARLON) as replaced by Baldwin H9043. Form/fit listing without published performance data — verify micron grade, collapse rating and seal configuration before substituting. |
Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.
How the H9043 model number is decoded
- H9043Baldwin filter part number per the Form 561 Number-Finder cross-reference.
Typical equipment & applications
- Hydraulic / transmission filtration — listed in the Baldwin Form 561 Number-Finder cross-reference.
Selection pitfalls — read before you substitute
- “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
- Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
- End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.
Frequently asked questions
What replaces the H9043 filter element?
How do I read the H9043 part number?
Is a same-envelope aftermarket element always a drop-in replacement?
How often should a hydraulic return-line element be replaced?
Other models in the Form 561 Interchange series
All 1208 →Reviewed & verified by the ElementRef engineering desk against Baldwin Filters on 2026-09-30. Read our editorial & correction policy.