ARGO-HYTOS · Filter Elements · inline line

V3.0510-78K1 filter element: specifications & equivalents

The V3.0510-78K1 is a ARGO-HYTOS inline-line hydraulic filter element, built with glass fiber media, sized 45.5 × 104.5 mm OD × length (ID 20 mm), rated at 16 µm class. Verify against the current manufacturer data sheet before ordering.

Envelope OD × L 45.5 × 104.5 mm
Inside diameter 20 mm
Filtration rating 16 µm nom.
Media Glass fiber
Collapse / burst 20 bar
Line type inline
Catalog verified. Parameters extracted from the manufacturer’s electronic catalog / official interchange document and checked 2026-09-28. Confidence score 0.90.

Dimensions, filter fineness and collapse pressure are taken from the ARGO-HYTOS product portal. Beta efficiency per ISO 16889 and seal material vary by execution — verify against the current ARGO-HYTOS data sheet before ordering.

Specification table

ParameterValue
Filter type inline line
Media Glass fiber
Filtration rating 16 µm
Rating basis nominal
Outside diameter OD 45.5 mm
Inside diameter ID 20 mm
Length 104.5 mm
End caps open-ended cartridge element
Collapse / burst pressure 20 bar
Integral bypass valve none (housing/valve-dependent)
Manufacturer part no. 43197500
Source catalog ARGO-HYTOS: ARGO-HYTOS product portal (portal.argo-hytos.com)
Last verified2026-09-28

Sources: ARGO-HYTOS — ARGO-HYTOS product portal (portal.argo-hytos.com) — accessed 2026-09-28.

ARGO-HYTOS® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized ARGO-HYTOS distributor.

Dimensions & series range

Outside diameter45.5 mm (1.791 in)
Inside diameter20 mm (0.787 in)
Overall length104.5 mm (4.114 in)

Cross references & equivalents

No catalog-verified cross references yet. This model is in the manual verification queue — request a verified equivalent.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the V3.0510-78K1 model number is decoded

  • V3.0510-78K1ARGO-HYTOS filter element part number (EXAPOR® MAX 3 Element) per the official product portal.
  • 16 µmPublished filter fineness (nominal rating as printed by ARGO-HYTOS).
  • 45.5 mmOuter diameter.
  • 20 mmInner diameter.
  • 104.5 mmElement length.
  • 20 barElement collapse pressure rating.
  • 2.5 barBypass valve opening pressure.
  • Glass fiberFilter media.

Typical equipment & applications

  • Replacement element for ARGO-HYTOS hydraulic filter housings
  • Mobile and industrial hydraulic circuits

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What are the dimensions of the V3.0510-78K1 filter element?
The published envelope is 45.5 mm OD × 104.5 mm length with a 20 mm inside diameter (1.791 × 4.114 in × 0.787 in ID). Confirm against the housing drawing before ordering.
What micron rating does V3.0510-78K1 use?
This element is rated 16 µm (nominal class). Always compare Beta ratings at the same test point: two brands may print different micron numbers for the same physical grade.
What replaces the V3.0510-78K1 filter element?
Cross references are being verified for this model — use the inquiry form and the engineering desk will confirm equivalents.
How do I read the V3.0510-78K1 part number?
See the designation decoder above: each segment of AHV3051078K1 encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the Filter Elements series

All 662 →

Reviewed & verified by the ElementRef engineering desk against ARGO-HYTOS on 2026-09-28. Read our editorial & correction policy.