ARGO-HYTOS · Breather Filters · inline line

L1.0506-195S filter element: specifications & equivalents

The L1.0506-195S is a ARGO-HYTOS inline-line hydraulic filter element. Verify against the current manufacturer data sheet before ordering.

Line type inline
Partially verified. Fit and grade trace to an official interchange document; dimensional values are compiled from 0 aftermarket listing(s) and must be confirmed against the manufacturer housing drawing. Confidence score 0.88.

Air flow, connection and filter fineness are taken from the ARGO-HYTOS product portal. Verify mounting configuration against the current ARGO-HYTOS data sheet before ordering.

Specification table

ParameterValue
Filter type inline line
Rated flow 15 L/min
Integral bypass valve none (housing/valve-dependent)
Mass 97 g
Manufacturer part no. 40678800
Source catalog ARGO-HYTOS: ARGO-HYTOS product portal (portal.argo-hytos.com)
Last verified2026-09-28

Sources: ARGO-HYTOS — ARGO-HYTOS product portal (portal.argo-hytos.com) — accessed 2026-09-28.

ARGO-HYTOS® and all model designations are trademarks of their respective owners, used here for identification only — ElementRef is an independent reference site, not an authorized ARGO-HYTOS distributor.

Cross references & equivalents

No catalog-verified cross references yet. This model is in the manual verification queue — request a verified equivalent.

Interchange levels: full catalog-confirmed drop-in · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the L1.0506-195S model number is decoded

  • L1.0506-195SARGO-HYTOS tank breather / filling filter part number (Ventilating Filter) per the official product portal.
  • 15 l/minRated air flow.
  • Rundgewinde Rd 42Connection / port configuration.

Typical equipment & applications

  • Hydraulic reservoir ventilation
  • Tank filling and breather filtration

Selection pitfalls — read before you substitute

  • “10 µm nominal” and “12 µm at β1000” can describe the very same media — one is reported at β≥200, the other at β≥1000 per ISO 16889. Compare ratings at the same Beta test point, not just the printed micron number.
  • Nitrile (NBR) seals are standard for mineral hydraulic oil but fail early in some phosphate-ester fluids and at sustained high temperature; verify seal compound against the fluid data sheet (fluorocarbon/Viton executions may be required).
  • End-cap geometry and the number/position of O-rings block interchange even when OD and length match — visually compare end caps before fitting, especially with aftermarket cartridges.

Frequently asked questions

What replaces the L1.0506-195S filter element?
Cross references are being verified for this model — use the inquiry form and the engineering desk will confirm equivalents.
How do I read the L1.0506-195S part number?
See the designation decoder above: each segment of AHL10506195S encodes size, line type, filtration grade and media/collapse execution.
Is a same-envelope aftermarket element always a drop-in replacement?
No. Matching OD and length only proves the cartridge fits the bowl. End-cap style, seal compound, micron/Beta rating, collapse pressure and bypass configuration must also match; the table above tags every equivalent as full, partial or verify for exactly this reason.
How often should a hydraulic return-line element be replaced?
Replace at the housing manufacturer’s recommended differential-pressure setting (commonly signalled by a clogging indicator), or on a time-based service interval when no indicator is fitted — never wait for bypass to open continuously, because unfiltered oil then reaches the valves.

Other models in the Breather Filters series

All 117 →

Reviewed & verified by the ElementRef engineering desk against ARGO-HYTOS on 2026-09-28. Read our editorial & correction policy.