Envelope interchange · 3.90×27.72 in

99×704 mm filter elements

30 elements from 1 brand(s) share this envelope: 99 mm outside diameter and 704 mm overall length (3.90×27.72 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
5.03.27 D 01 BN4 /-V HYDAC 40.9 1 β1 > 1000 10 housing Fluorocarbon (Viton) pressure
5.03.27 D 03 BH4 HYDAC 40.9 3 β3 > 1000 (HYDAC grade convention: β5(c) ≥ 1000) 210 housing Nitrile (Buna-N) pressure
5.03.27 D 03 BH4 /-V HYDAC 40.9 3 β3 > 1000 (HYDAC grade convention: β5(c) ≥ 1000) 210 housing Fluorocarbon (Viton) pressure
5.03.27 D 03 BN4 HYDAC 40.9 3 β3 > 1000 (HYDAC grade convention: β5(c) ≥ 1000) 10 housing Nitrile (Buna-N) pressure
5.03.27 D 03 BN4 /-V HYDAC 40.9 3 β3 > 1000 (HYDAC grade convention: β5(c) ≥ 1000) 10 housing Fluorocarbon (Viton) pressure
5.03.27 D 03 OH/PS /-V HYDAC 40.9 3 β3 > 1000 (HYDAC grade convention: β5(c) ≥ 1000) 210 housing Fluorocarbon (Viton) pressure
5.03.27 D 05 BH4 HYDAC 40.9 5 β5 > 1000 (HYDAC grade convention: β7(c) ≥ 1000) 210 housing Nitrile (Buna-N) pressure
5.03.27 D 05 BH4 /-02081981 HYDAC 40.9 5 β5 > 1000 (HYDAC grade convention: β7(c) ≥ 1000) 210 housing Nitrile (Buna-N) pressure
5.03.27 D 05 BH4 /-SFREE HYDAC 40.9 5 β5 > 1000 (HYDAC grade convention: β7(c) ≥ 1000) 210 housing Nitrile (Buna-N) pressure
5.03.27 D 05 BH4 /-V HYDAC 40.9 5 β5 > 1000 (HYDAC grade convention: β7(c) ≥ 1000) 210 housing Fluorocarbon (Viton) pressure
5.03.27 D 05 BN4 HYDAC 40.9 5 β5 > 1000 (HYDAC grade convention: β7(c) ≥ 1000) 10 housing Nitrile (Buna-N) pressure
5.03.27 D 05 BN4 /-SFREE HYDAC 40.9 5 β5 > 1000 (HYDAC grade convention: β7(c) ≥ 1000) 10 housing Nitrile (Buna-N) pressure
5.03.27 D 05 BN4 /-V HYDAC 40.9 5 β5 > 1000 (HYDAC grade convention: β7(c) ≥ 1000) 10 housing Fluorocarbon (Viton) pressure
5.03.27 D 05 BN4 /-V-G HYDAC 40.9 5 β5 > 1000 (HYDAC grade convention: β7(c) ≥ 1000) 10 housing Fluorocarbon (Viton) pressure
5.03.27 D 05 OH/PS /-V HYDAC 40.9 5 β5 > 1000 (HYDAC grade convention: β7(c) ≥ 1000) 210 housing Fluorocarbon (Viton) pressure
5.03.27 D 10 BH4 HYDAC 40.9 10 β10 > 1000 (HYDAC grade convention: β12(c) ≥ 1000) 210 housing Nitrile (Buna-N) pressure
5.03.27 D 10 BH4 /-V HYDAC 40.9 10 β10 > 1000 (HYDAC grade convention: β12(c) ≥ 1000) 210 housing Fluorocarbon (Viton) pressure
5.03.27 D 10 BN4 HYDAC 40.9 10 β10 > 1000 (HYDAC grade convention: β12(c) ≥ 1000) 10 housing Nitrile (Buna-N) pressure
5.03.27 D 10 BN4 /-V HYDAC 40.9 10 β10 > 1000 (HYDAC grade convention: β12(c) ≥ 1000) 10 housing Fluorocarbon (Viton) pressure
5.03.27 D 10 BN4 /-V-G HYDAC 40.9 10 β10 > 1000 (HYDAC grade convention: β12(c) ≥ 1000) 10 housing Fluorocarbon (Viton) pressure
5.03.27 D 10 BN4 /-V-SO103H HYDAC 40.9 10 β10 > 1000 (HYDAC grade convention: β12(c) ≥ 1000) 10 housing Fluorocarbon (Viton) pressure
5.03.27 D 10 OH/PS /-V HYDAC 40.9 10 β10 > 1000 (HYDAC grade convention: β12(c) ≥ 1000) 210 housing Fluorocarbon (Viton) pressure
5.03.27 D 149 W HYDAC 40.9 149 — 10 housing Nitrile (Buna-N) pressure
5.03.27 D 20 BH4 HYDAC 40.9 20 β20 > 1000 (HYDAC grade convention: β22(c) ≥ 1000) 210 housing Nitrile (Buna-N) pressure
5.03.27 D 20 BN4 HYDAC 40.9 20 β20 > 1000 (HYDAC grade convention: β22(c) ≥ 1000) 10 housing Nitrile (Buna-N) pressure
5.03.27 D 20 BN4 /-V HYDAC 40.9 20 β20 > 1000 (HYDAC grade convention: β22(c) ≥ 1000) 10 housing Fluorocarbon (Viton) pressure
5.03.27 D 20 BN4 /-V-G HYDAC 40.9 20 β20 > 1000 (HYDAC grade convention: β22(c) ≥ 1000) 10 housing Fluorocarbon (Viton) pressure
5.03.27 D 25 W HYDAC 40.9 25 — 10 housing Nitrile (Buna-N) pressure
5.03.27 D 40 AM HYDAC 40.9 40 β40 > 30 10 housing Nitrile (Buna-N) pressure
5.03.27 D 40 AM /-V HYDAC 40.9 40 β40 > 30 10 housing Fluorocarbon (Viton) pressure

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 99×704 mm filter elements interchangeable?
They share the same physical envelope — 99 mm OD and 704 mm length (3.90×27.72 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 30 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 99×704 mm in inches?
99×704 mm converts to approximately 3.90×27.72 in.

Browse all 99 mm OD elements or open the dimensions finder.