ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
51482 WIX Filters — 8 — 68.947 housing Nitrile (NBR) return
51491 WIX Filters — 10 — 68.947 housing Nitrile (NBR) return
51494 WIX Filters — 5 — 68.947 housing Nitrile (NBR) return
51483 WIX Filters — 19 β2 = 9, β20 = 19 68.947 housing Nitrile (NBR) return
51492 WIX Filters — 15 β2 = 15, β20 = 30 68.947 housing Nitrile (NBR) return
51496 WIX Filters — 3 β2 = 2, β20 = 3 68.947 housing Nitrile (NBR) return
51486 WIX Filters — 9 β2 = 6, β20 = 10 68.947 housing Nitrile (NBR) return
51495 WIX Filters — 17 β20 = 17, β75 = 23 68.947 housing Nitrile (NBR) return
51498 WIX Filters — 33 — 68.947 housing Nitrile (NBR) return
57247 WIX Filters — 2 β2 = 2, β75 = 10 68.947 housing Nitrile (NBR) return

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 97×241 mm filter elements interchangeable?
They share the same physical envelope — 97 mm OD and 241 mm length (3.82×9.49 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 10 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 97×241 mm in inches?
97×241 mm converts to approximately 3.82×9.49 in.