Envelope interchange · 3.70×12.60 in

94×320 mm filter elements

4 elements from 2 brand(s) share this envelope: 94 mm outside diameter and 320 mm overall length (3.70×12.60 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
4.14.13 D 10 BN4 /-V HYDAC 44.7 10 β10 > 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 housing Fluorocarbon (Viton) pressure
4.94.300 D 10 BN4 HYDAC 48 10 β10 > 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 housing Nitrile (Buna-N) pressure
HF29251 Fleetguard 48.6 — 3 µm at β200(c); 4.5 µm at β1000(c) per ISO 16889 — housing — inline
HF29252 Fleetguard 48.6 — 9.9 µm at β200(c); 12.4 µm at β1000(c) per ISO 16889 — housing — inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 94×320 mm filter elements interchangeable?
They share the same physical envelope — 94 mm OD and 320 mm length (3.70×12.60 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 4 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 94×320 mm in inches?
94×320 mm converts to approximately 3.70×12.60 in.

Browse all 94 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.