Envelope interchange · 3.66×9.29 in
93×236 mm filter elements
37 elements from 2 brand(s) share this envelope: 93 mm outside diameter and 236 mm overall length (3.66×9.29 in).
Dimensional interchange — verify before substituting. These cartridges fit the
same bowl space; they are not guaranteed drop-in equivalents. Compare grade,
end caps, seals, collapse rating and bypass configuration for the specific duty.
| Model | Brand | ID (mm) | Micron | β rating | Collapse (bar) | Bypass | Seal | Type |
|---|---|---|---|---|---|---|---|---|
| 57318 | WIX Filters | 44 | 10 | β2 = 10 | — | housing | Nitrile (NBR) | return |
| S4110C03 | Filtrec | 44 | 3 | β3(c)≥2 | — | housing | — | inline |
| S4110C03V | Filtrec | 44 | 3 | β3(c)≥2 | — | housing | — | inline |
| S4110C10 | Filtrec | 44 | 10 | β10(c)≥2 | — | housing | — | inline |
| S4110C10V | Filtrec | 44 | 10 | β10(c)≥2 | — | housing | — | inline |
| S4110C25 | Filtrec | 44 | 25 | β25(c)≥2 | — | housing | — | inline |
| S4110C25V | Filtrec | 44 | 25 | β25(c)≥2 | — | housing | — | inline |
| S4110CW10 | Filtrec | 44 | — | — | — | housing | — | inline |
| S4110CW10V | Filtrec | 44 | — | — | — | housing | — | inline |
| S4110CW25 | Filtrec | 44 | — | — | — | housing | — | inline |
| S4110CW25V | Filtrec | 44 | — | — | — | housing | — | inline |
| S4110G03 | Filtrec | 44 | 5 | β5(c)≥1000 | — | housing | — | inline |
| S4110G03V | Filtrec | 44 | 5 | β5(c)≥1000 | — | housing | — | inline |
| S4110G06 | Filtrec | 44 | 7 | β7(c)≥1000 | — | housing | — | inline |
| S4110G06V | Filtrec | 44 | 7 | β7(c)≥1000 | — | housing | — | inline |
| S4110G10 | Filtrec | 44 | 12 | β12(c)≥1000 | — | housing | — | inline |
| S4110G10V | Filtrec | 44 | 12 | β12(c)≥1000 | — | housing | — | inline |
| S4110G25 | Filtrec | 44 | 22 | β22(c)≥1000 | — | housing | — | inline |
| S4110G25V | Filtrec | 44 | 22 | β22(c)≥1000 | — | housing | — | inline |
| S4110GW03 | Filtrec | 44 | 5 | β5(c)≥1000 | — | housing | — | inline |
| S4110GW03V | Filtrec | 44 | 5 | β5(c)≥1000 | — | housing | — | inline |
| S4110GW06 | Filtrec | 44 | 7 | β7(c)≥1000 | — | housing | — | inline |
| S4110GW06V | Filtrec | 44 | 7 | β7(c)≥1000 | — | housing | — | inline |
| S4110GW10 | Filtrec | 44 | 12 | β12(c)≥1000 | — | housing | — | inline |
| S4110GW10V | Filtrec | 44 | 12 | β12(c)≥1000 | — | housing | — | inline |
| S4110GW25 | Filtrec | 44 | 22 | β22(c)≥1000 | — | housing | — | inline |
| S4110GW25V | Filtrec | 44 | 12 | β12(c)≥1000 | — | housing | — | inline |
| S4110P40 | Filtrec | 44 | — | — | — | housing | — | inline |
| S4110P40V | Filtrec | 44 | — | — | — | housing | — | inline |
| S4110T149 | Filtrec | 44 | — | — | — | housing | — | inline |
| S4110T149V | Filtrec | 44 | — | — | — | housing | — | inline |
| S4110T25 | Filtrec | 44 | 25 | — | — | housing | — | inline |
| S4110T25V | Filtrec | 44 | 25 | — | — | housing | — | inline |
| S4110T40 | Filtrec | 44 | 40 | — | — | housing | — | inline |
| S4110T40V | Filtrec | 44 | 40 | — | — | housing | — | inline |
| S4110T74 | Filtrec | 44 | — | — | — | housing | — | inline |
| S4110T74V | Filtrec | 44 | — | — | — | housing | — | inline |
Substitution verification checklist
- Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
- End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
- Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
- Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
- Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.
Frequently asked questions
Are all 93×236 mm filter elements interchangeable?
They share the same physical envelope — 93 mm OD and 236 mm length (3.66×9.29 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 37 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 93×236 mm in inches?
93×236 mm converts to approximately 3.66×9.29 in.
Browse all 93 mm OD elements or open the dimensions finder.
Request quote & availability
First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.