Envelope interchange · 3.66×5.83 in
93×148 mm filter elements
27 elements from 3 brand(s) share this envelope: 93 mm outside diameter and 148 mm overall length (3.66×5.83 in).
Dimensional interchange — verify before substituting. These cartridges fit the
same bowl space; they are not guaranteed drop-in equivalents. Compare grade,
end caps, seals, collapse rating and bypass configuration for the specific duty.
| Model | Brand | ID (mm) | Micron | β rating | Collapse (bar) | Bypass | Seal | Type |
|---|---|---|---|---|---|---|---|---|
| 57252 | WIX Filters | — | 20 | — | 22.5 | housing | Nitrile (NBR) | return |
| WDK940/20 | MANN-FILTER | — | — | — | — | housing | — | inline |
| HF30008 | Fleetguard | — | 1 | TWA 1 µm at β=2; 5 µm at β75(c); 6 µm at β200(c) per ISO 16889 | — | housing | — | return |
| HF30014 | Fleetguard | — | 3 | TWA 3 µm at β=2; 10 µm at β75(c); 12 µm at β200(c) per ISO 16889 | — | housing | — | return |
| HF30195 | Fleetguard | — | — | 3 µm at β200(c) per ISO 16889 | — | housing | — | return |
| HF30399 | Fleetguard | — | 5 | TWA 5 µm at β=2; 15 µm at β75(c); 25 µm at β200(c) per ISO 16889 | — | housing | — | return |
| HF6056 | Fleetguard | — | 16 | TWA 16 µm at β=2 per ISO 16889 | — | housing | — | return |
| HF6057 | Fleetguard | — | 22 | TWA 22 µm at β=2 per ISO 16889 | — | housing | — | return |
| HF6116 | Fleetguard | — | 16 | TWA 16 µm at β=2 per ISO 16889 | — | housing | — | return |
| HF6117 | Fleetguard | — | 22 | TWA 22 µm at β=2 per ISO 16889 | — | housing | — | return |
| HF6121 | Fleetguard | — | 16 | TWA 16 µm at β=2 per ISO 16889 | — | housing | — | return |
| HF6281 | Fleetguard | — | 10 | TWA 10 µm at β=2 per ISO 16889 | — | housing | — | return |
| HF6457 | Fleetguard | — | 33 | TWA 33 µm at β=2 per ISO 16889 | — | housing | — | return |
| HF6502 | Fleetguard | — | — | — | — | housing | — | return |
| HF6504 | Fleetguard | — | 10 | TWA 10 µm at β=2 per ISO 16889 | — | housing | — | return |
| HF6505 | Fleetguard | — | 4 | TWA 4 µm at β=2 per ISO 16889 | — | housing | — | return |
| HF6583 | Fleetguard | — | 1 | TWA 1 µm at β=2 per ISO 16889 | — | housing | — | return |
| HF6600 | Fleetguard | — | 1 | TWA 1 µm at β=2 per ISO 16889 | — | housing | — | return |
| HF6603 | Fleetguard | — | — | — | — | housing | — | return |
| HF6606 | Fleetguard | — | — | — | — | housing | — | return |
| HF6610 | Fleetguard | — | 16 | TWA 16 µm at β=2 per ISO 16889 | — | housing | — | return |
| HF6612 | Fleetguard | — | 4 | TWA 4 µm at β=2 per ISO 16889 | — | housing | — | return |
| HF6620 | Fleetguard | — | 14 | TWA 14 µm at β=2 per ISO 16889 | — | housing | — | return |
| HF6625 | Fleetguard | — | 9 | TWA 9 µm at β=2 per ISO 16889 | — | housing | — | return |
| HF6630 | Fleetguard | — | 1 | TWA 1 µm at β=2; 14 µm at β75(c); 18 µm at β200(c) per ISO 16889 | — | housing | — | return |
| HF6632 | Fleetguard | — | 10 | TWA 10 µm at β=2; 25 µm at β75(c); 33 µm at β200(c) per ISO 16889 | — | housing | — | return |
| HF7608 | Fleetguard | — | 4 | TWA 4 µm at β=2; 15.8 µm at β75(c); 18.7 µm at β200(c) per ISO 16889 | — | housing | — | return |
Substitution verification checklist
- Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
- End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
- Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
- Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
- Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.
Frequently asked questions
Are all 93×148 mm filter elements interchangeable?
They share the same physical envelope — 93 mm OD and 148 mm length (3.66×5.83 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 27 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 93×148 mm in inches?
93×148 mm converts to approximately 3.66×5.83 in.
Browse all 93 mm OD elements or open the dimensions finder.