Envelope interchange · 3.58×9.96 in

91×253 mm filter elements

60 elements from 4 brand(s) share this envelope: 91 mm outside diameter and 253 mm overall length (3.58×9.96 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
HD1043 MANN-FILTER 49 — — — housing — inline
HD1043/1 MANN-FILTER 49 — — — housing — inline
HD1043/2 MANN-FILTER 49 — — — housing — inline
SE-130-G-03-B STAUFF 48.5 — — — housing — inline
SE-130-G-03-V STAUFF 48.5 — — — housing — inline
SE-130-G-05-B STAUFF 48.5 — — — housing — inline
SE-130-G-05-V STAUFF 48.5 — — — housing — inline
SE-130-G-10-B STAUFF 48.5 — — — housing — inline
SE-130-G-10-V STAUFF 48.5 — — — housing — inline
SE-130-G-20-B STAUFF 48.5 — — — housing — inline
SE-130-G-20-V STAUFF 48.5 — — — housing — inline
SE-130-H-03-B STAUFF 48.5 — — — housing — inline
SE-130-H-03-V STAUFF 48.5 — — — housing — inline
SE-130-H-05-B STAUFF 48.5 — — — housing — inline
SE-130-H-05-V STAUFF 48.5 — — — housing — inline
SE-130-H-10-B STAUFF 48.5 — — — housing — inline
SE-130-H-10-V STAUFF 48.5 — — — housing — inline
SE-130-H-20-B STAUFF 48.5 — — — housing — inline
SE-130-H-20-V STAUFF 48.5 — — — housing — inline
SE-130-S-100-B STAUFF 48.5 — — — housing — inline
SE-130-S-200-B STAUFF 48.5 — — — housing — inline
SE-130-S-25-B STAUFF 48.5 — — — housing — inline
SE-130-S-25-V STAUFF 48.5 — — — housing — inline
SE-130-S-50-B STAUFF 48.5 — — — housing — inline
HF6878 Fleetguard 48.5 10 10 µm at β75(c); 11 µm at β200(c) per ISO 16889 30 housing — inline
HF6879 Fleetguard 48.5 17 17 µm at β75(c) per ISO 16889 30 housing — inline
D1101G10A Filtrec 50 12 β12(c)≥1000 — housing — inline
D1101G10AV Filtrec 50 12 β12(c)≥1000 — housing — inline
D1101G10B Filtrec 50 12 β12(c)≥1000 — housing — inline
D1101G10BV Filtrec 50 12 β12(c)≥1000 — housing — inline
D1101G25A Filtrec 50 22 β22(c)≥1000 — housing — inline
D1101G25AV Filtrec 50 22 β22(c)≥1000 — housing — inline
D1101G25B Filtrec 50 22 β22(c)≥1000 — housing — inline
D1101G25BV Filtrec 50 22 β22(c)≥1000 — housing — inline
DHD500G03B Filtrec 48.2 5 β5(c)≥1000 — housing — inline
DHD500G03B/ESD Filtrec 48.2 5 β5(c)≥1000 — housing — inline
DHD500G03V Filtrec 48.2 5 β5(c)≥1000 — housing — inline
DHD500G03V/ESD Filtrec 48.2 5 β5(c)≥1000 — housing — inline
DHD500G05B Filtrec 48.2 7 β7(c)≥1000 — housing — inline
DHD500G05B/ESD Filtrec 48.2 7 β7(c)≥1000 — housing — inline
DHD500G05V Filtrec 48.2 7 β7(c)≥1000 — housing — inline
DHD500G05V/ESD Filtrec 48.2 7 β7(c)≥1000 — housing — inline
DHD500G10B Filtrec 48.2 12 β12(c)≥1000 — housing — inline
DHD500G10B/ESD Filtrec 48.2 12 β12(c)≥1000 — housing — inline
DHD500G10V Filtrec 48.2 12 β12(c)≥1000 — housing — inline
DHD500G10V/ESD Filtrec 48.2 12 β12(c)≥1000 — housing — inline
DHD500G20B Filtrec 48.2 22 β22(c)≥1000 — housing — inline
DHD500G20B/ESD Filtrec 48.2 22 β22(c)≥1000 — housing — inline
DHD500G20V Filtrec 48.2 22 β22(c)≥1000 — housing — inline
DHD500G20V/ESD Filtrec 48.2 22 β22(c)≥1000 — housing — inline
DHD500H03B Filtrec 48.1 5 β5(c)≥1000 — housing — inline
DHD500H03V Filtrec 48.1 5 β5(c)≥1000 — housing — inline
DHD500H05B Filtrec 48.1 7 β7(c)≥1000 — housing — inline
DHD500H05V Filtrec 48.1 7 β7(c)≥1000 — housing — inline
DHD500H10B Filtrec 48.1 12 β12(c)≥1000 — housing — inline
DHD500H10V Filtrec 48.1 12 β12(c)≥1000 — housing — inline
DHD500H20B Filtrec 48.1 22 β22(c)≥1000 — housing — inline
DHD500H20V Filtrec 48.1 22 β22(c)≥1000 — housing — inline
DHD500S100B Filtrec 48.2 100 — — housing — inline
DHD500S25B Filtrec 48.2 25 — — housing — inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 91×253 mm filter elements interchangeable?
They share the same physical envelope — 91 mm OD and 253 mm length (3.58×9.96 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 60 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 91×253 mm in inches?
91×253 mm converts to approximately 3.58×9.96 in.

Browse all 91 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.