Envelope interchange · 3.50×9.02 in
89×229 mm filter elements
26 elements from 2 brand(s) share this envelope: 89 mm outside diameter and 229 mm overall length (3.50×9.02 in).
Dimensional interchange — verify before substituting. These cartridges fit the
same bowl space; they are not guaranteed drop-in equivalents. Compare grade,
end caps, seals, collapse rating and bypass configuration for the specific duty.
| Model | Brand | ID (mm) | Micron | β rating | Collapse (bar) | Bypass | Seal | Type |
|---|---|---|---|---|---|---|---|---|
| 5.02.09 D 03 BN4 | HYDAC | 46 | 3 | β3 > 1000 (HYDAC grade convention: β5(c) ≥ 1000) | 20 | housing | Nitrile (Buna-N) | pressure |
| 5.02.09 D 03 P | HYDAC | 46 | 3 | β5(c) ≥ 1000 per ISO 16889 | 10 | housing | Nitrile (Buna-N) | pressure |
| 5.02.09 D 05 BN4 | HYDAC | 46 | 5 | β5 > 1000 (HYDAC grade convention: β7(c) ≥ 1000) | 20 | housing | Nitrile (Buna-N) | pressure |
| 5.02.09 D 10 BN4 | HYDAC | 46 | 10 | β10 > 1000 (HYDAC grade convention: β12(c) ≥ 1000) | 20 | housing | Nitrile (Buna-N) | pressure |
| 5.02.09 D 10 P | HYDAC | 46 | 10 | β12(c) ≥ 1000 per ISO 16889 | 10 | housing | Nitrile (Buna-N) | pressure |
| 5.02.09 D 20 BN4 | HYDAC | 46 | 20 | β20 > 1000 (HYDAC grade convention: β22(c) ≥ 1000) | 20 | housing | Nitrile (Buna-N) | pressure |
| 5.02.09 D 25 P | HYDAC | 46 | 25 | — | 10 | housing | Nitrile (Buna-N) | pressure |
| J10 | Schroeder Industries | 41 | 10 | 18 µm at β(c) ≥ 200 (99.5% efficiency) | 10.3 | housing | Nitrile (Buna-N) | inline |
| J10C | Schroeder Industries | 41 | 10 | 18 µm at β(c) ≥ 200 (99.5% efficiency) | 10.3 | housing | Neoprene | inline |
| J25 | Schroeder Industries | 41 | 25 | β(c) ≥ 1000 (99.5% efficiency) | 10.3 | housing | Nitrile (Buna-N) | inline |
| J25V | Schroeder Industries | 41 | 25 | β(c) ≥ 1000 (99.5% efficiency) | 10.3 | housing | Fluorocarbon (Viton) | inline |
| J3 | Schroeder Industries | 41 | 3 | 10 µm at β(c) ≥ 200 (99.5% efficiency) | 10.3 | housing | Nitrile (Buna-N) | inline |
| JZ1 | Schroeder Industries | 41 | 1 | 4.2 µm at β(c) ≥ 1000 (99.9% efficiency) | 10.3 | housing | Nitrile (Buna-N) | inline |
| JZ10 | Schroeder Industries | 41 | 10 | 10 µm at β(c) ≥ 1000 (99.9% efficiency) | 10.3 | housing | Nitrile (Buna-N) | inline |
| JZ10H | Schroeder Industries | 41 | 10 | 10 µm at β(c) ≥ 1000 (99.9% efficiency) | 10.3 | housing | Ethylene Propylene Rubber (EPR) | inline |
| JZ10H.5 | Schroeder Industries | 41 | 10 | 10 µm at β(c) ≥ 1000 (99.9% efficiency) | 10.3 | housing | Ethylene Propylene Rubber (EPR) | inline |
| JZ10V | Schroeder Industries | 41 | 10 | 10 µm at β(c) ≥ 1000 (99.9% efficiency) | 10.3 | housing | Fluorocarbon (Viton) | inline |
| JZ1V | Schroeder Industries | 41 | 1 | 4.2 µm at β(c) ≥ 1000 (99.9% efficiency) | 10.3 | housing | Fluorocarbon (Viton) | inline |
| JZ25 | Schroeder Industries | 41 | 25 | 24 µm at β(c) ≥ 1000 (99.9% efficiency) | 10.3 | housing | Nitrile (Buna-N) | inline |
| JZ25H | Schroeder Industries | 41 | 25 | 24 µm at β(c) ≥ 1000 (99.9% efficiency) | 10.3 | housing | Ethylene Propylene Rubber (EPR) | inline |
| JZ25V | Schroeder Industries | 41 | 25 | 24 µm at β(c) ≥ 1000 (99.9% efficiency) | 10.3 | housing | Fluorocarbon (Viton) | inline |
| JZ3 | Schroeder Industries | 41 | 3 | 4.8 µm at β(c) ≥ 1000 (99.9% efficiency) | 10.3 | housing | Nitrile (Buna-N) | inline |
| JZ3H | Schroeder Industries | 41 | 3 | 4.8 µm at β(c) ≥ 1000 (99.9% efficiency) | 10.3 | housing | Ethylene Propylene Rubber (EPR) | inline |
| JZ3V | Schroeder Industries | 41 | 3 | 4.8 µm at β(c) ≥ 1000 (99.9% efficiency) | 10.3 | housing | Fluorocarbon (Viton) | inline |
| JZ5 | Schroeder Industries | 41 | 5 | 6.3 µm at β(c) ≥ 1000 (99.9% efficiency) | 10.3 | housing | Nitrile (Buna-N) | inline |
| JZ5V | Schroeder Industries | 41 | 5 | 6.3 µm at β(c) ≥ 1000 (99.9% efficiency) | 10.3 | housing | Fluorocarbon (Viton) | inline |
Substitution verification checklist
- Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
- End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
- Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
- Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
- Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.
Frequently asked questions
Are all 89×229 mm filter elements interchangeable?
They share the same physical envelope — 89 mm OD and 229 mm length (3.50×9.02 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 26 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 89×229 mm in inches?
89×229 mm converts to approximately 3.50×9.02 in.
Browse all 89 mm OD elements or open the dimensions finder.
Request quote & availability
First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.