Envelope interchange · 3.15×13.78 in

80×350 mm filter elements

63 elements from 1 brand(s) share this envelope: 80 mm outside diameter and 350 mm overall length (3.15×13.78 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
01.E 600.10VG.30.E.P.- Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) pressure
01.E 600.10VG.HR.E.P.- Eaton / Internormen — 10 — 160 housing Nitrile (Buna-N) pressure
01.E 600.3VG.HR.E.P.- Eaton / Internormen — 5 — 160 housing Nitrile (Buna-N) pressure
01.E 600.10VG.HR.E.V.- Eaton / Internormen — 10 — 160 housing Fluorocarbon (Viton) pressure
01.E 600.25VG.30.E.P.- Eaton / Internormen — 20 — 30 housing Nitrile (Buna-N) pressure
01.E 600.25VG.HR.E.P.- Eaton / Internormen — 20 — 160 housing Nitrile (Buna-N) pressure
01.E 600.80G.30.E.P.- Eaton / Internormen — 80 — 30 housing Nitrile (Buna-N) pressure
01.E 600.6VG.HR.E.P.- Eaton / Internormen — 7 — 160 housing Nitrile (Buna-N) pressure
01.E 600.16VG.30.E.P.- Eaton / Internormen — 15 — 30 housing Nitrile (Buna-N) pressure
01.E 600.16VG.HR.E.P.- Eaton / Internormen — 15 — 160 housing Nitrile (Buna-N) pressure
01.E 600.10VG.30.E.V.- Eaton / Internormen — 10 — 30 housing Fluorocarbon (Viton) pressure
01.E 600.6VG.30.E.P.- Eaton / Internormen — 7 — 30 housing Nitrile (Buna-N) pressure
01.E 600.130G.30.E.P.- Eaton / Internormen — 130 — 30 housing Nitrile (Buna-N) pressure
01.E 600.80G.HR.E.P.VA Eaton / Internormen — 80 — 160 housing Nitrile (Buna-N) pressure
01.E 600.25G.HR.E.P.- Eaton / Internormen — 25 — 160 housing Nitrile (Buna-N) pressure
01.E 600.40G.HR.E.V.- Eaton / Internormen — 40 — 160 housing Fluorocarbon (Viton) inline
01.E 600.10G.30.E.P.- Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) pressure
01.E 600.25G.30.E.P.- Eaton / Internormen — 25 — 30 housing Nitrile (Buna-N) inline
01.E 600.25G.HR.E.P.VA Eaton / Internormen — 25 — 160 housing Nitrile (Buna-N) pressure
01.E 600.10VG.30.E.P.IS06 Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) pressure
01.E 600.25VG.30.E.P.IS06 Eaton / Internormen — 20 — 30 housing Nitrile (Buna-N) pressure
01.E 600.10VG.30.E.V.IS06 Eaton / Internormen — 10 — 30 housing Fluorocarbon (Viton) pressure
01.E 600.3VG.HR.E.P.IS06 Eaton / Internormen — 5 — 160 housing Nitrile (Buna-N) pressure
01.E 600.3VG.30.E.P.- Eaton / Internormen — 5 — 30 housing Nitrile (Buna-N) pressure
01.E 600.6VG.HR.E.P.IS06 Eaton / Internormen — 7 — 160 housing Nitrile (Buna-N) pressure
01.E 600.25VG.HR.E.P.IS06 Eaton / Internormen — 20 — 160 housing Nitrile (Buna-N) pressure
01.E 600.10VG.HR.E.P.IS06 Eaton / Internormen — 10 — 160 housing Nitrile (Buna-N) pressure
01.E 600.10VG.30.E.V.VA Eaton / Internormen — 10 — 30 housing Fluorocarbon (Viton) inline
01.E 600.40G.30.E.V.VA Eaton / Internormen — 40 — 30 housing Fluorocarbon (Viton) inline
01.E 600.6VG.30.E.P.VA Eaton / Internormen — 7 — 30 housing Nitrile (Buna-N) pressure
01.E 600.40G.30.E.P.- Eaton / Internormen — 40 — 30 housing Nitrile (Buna-N) pressure
01.E 600.250G.HR.E.P.- Eaton / Internormen — 250 — 160 housing Nitrile (Buna-N) pressure
01.E 600.6VG.HR.E.V.- Eaton / Internormen — 7 — 160 housing Fluorocarbon (Viton) pressure
01.E 600.25VG.30.E.V.- Eaton / Internormen — 20 — 30 housing Fluorocarbon (Viton) inline
01.E 600.3VG.HR.E.V.- Eaton / Internormen — 5 — 160 housing Fluorocarbon (Viton) pressure
01.E 600.3VG.30.E.V.VA Eaton / Internormen — 5 — 30 housing Fluorocarbon (Viton) inline
01.E 600.25VG.HR.E.V.- Eaton / Internormen — 20 — 160 housing Fluorocarbon (Viton) inline
01.E 600.3VG.30.E.V.- Eaton / Internormen — 5 — 30 housing Fluorocarbon (Viton) inline
01.E 600.40G.30.E.V.- Eaton / Internormen — 40 — 30 housing Fluorocarbon (Viton) pressure
01.E 600.25G.30.E.V.- Eaton / Internormen — 25 — 30 housing Fluorocarbon (Viton) pressure
01.E 600.130G.30.E.V.- Eaton / Internormen — 130 — 30 housing Fluorocarbon (Viton) inline
01.E 600.3VG.30.E.EPDM.- Eaton / Internormen — 5 — 30 housing EPDM pressure
01.E 600.80G.HR.E.V.IS06 Eaton / Internormen — 80 — 160 housing Fluorocarbon (Viton) pressure
01.E 600.10G.30.E.P.- FA. AVA Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) pressure
01.E 600.25VG.HR.E.V.IS06 Eaton / Internormen — 20 — 160 housing Fluorocarbon (Viton) pressure
01.E 600.16VG.HR.E.V.- Eaton / Internormen — 15 — 160 housing Fluorocarbon (Viton) pressure
01.E 600.80G.30.E.V.- Eaton / Internormen — 80 — 30 housing Fluorocarbon (Viton) inline
01.E 600.80G.HR.E.V.- Eaton / Internormen — 80 — 160 housing Fluorocarbon (Viton) pressure
01.E 600.1VG.HR.E.P.- Eaton / Internormen — 4 — 160 housing Nitrile (Buna-N) pressure
01.E 600.25VG.30.E.P.VA Eaton / Internormen — 20 — 30 housing Nitrile (Buna-N) inline
01.E 600.3VG.HR.E.P.VA Eaton / Internormen — 5 — 160 housing Nitrile (Buna-N) inline
01.E 600.25VG.HR.E.P.VA Eaton / Internormen — 20 — 160 housing Nitrile (Buna-N) pressure
01.E 600.130G.HR.E.P.- Eaton / Internormen — 130 — 160 housing Nitrile (Buna-N) inline
01.E 600.10G.HR.E.V.VA Eaton / Internormen — 10 — 160 housing Fluorocarbon (Viton) inline
01.E 600.10VG.HR.E.P.VA Eaton / Internormen — 10 — 160 housing Nitrile (Buna-N) inline
01.E 600.25G.HR.E.V.- Eaton / Internormen — 25 — 160 housing Fluorocarbon (Viton) inline
01.E 600.500G.HR.E.V.VA Eaton / Internormen — 500 — 160 housing Fluorocarbon (Viton) inline
01.E 600.3VG.HR.E.EPDM.- Eaton / Internormen — 5 — 160 housing EPDM pressure
01.E 600.1VG.30.E.V.VA Eaton / Internormen — 4 — 30 housing Fluorocarbon (Viton) pressure
01.E 600.250G.30.E.V.IS06 Eaton / Internormen — 250 — 30 housing Fluorocarbon (Viton) inline
01.E 600.130G.30.E.V.IS06 Eaton / Internormen — 130 — 30 housing Fluorocarbon (Viton) inline
01.E 600.80G.30.E.V.IS06 Eaton / Internormen — 80 — 30 housing Fluorocarbon (Viton) inline
01.E 600.1VG.30.E.V.- Eaton / Internormen — 4 — 30 housing Fluorocarbon (Viton) pressure

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 80×350 mm filter elements interchangeable?
They share the same physical envelope — 80 mm OD and 350 mm length (3.15×13.78 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 63 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 80×350 mm in inches?
80×350 mm converts to approximately 3.15×13.78 in.

Browse all 80 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.