Envelope interchange · 2.91×5.67 in
74×144 mm filter elements
122 elements from 6 brand(s) share this envelope: 74 mm outside diameter and 144 mm overall length (2.91×5.67 in).
Dimensional interchange — verify before substituting. These cartridges fit the
same bowl space; they are not guaranteed drop-in equivalents. Compare grade,
end caps, seals, collapse rating and bypass configuration for the specific duty.
| Model | Brand | ID (mm) | Micron | β rating | Collapse (bar) | Bypass | Seal | Type |
|---|---|---|---|---|---|---|---|---|
| 51089 | WIX Filters | — | 32 | — | — | housing | Nitrile (NBR) | return |
| HD819/1 | MANN-FILTER | 36 | — | — | — | housing | — | inline |
| RE-045-G-03-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-03-B-B6.0 | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-03-B-NB | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-03-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-03-V-B6.0 | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-03-V-NB | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-05-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-05-B-B6.0 | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-05-B-NB | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-05-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-05-V-B6.0 | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-05-V-NB | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-10-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-10-B-B1.0 | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-10-B-B6.0 | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-10-B-NB | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-10-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-10-V-B6.0 | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-10-V-NB | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-20-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-20-B-B6.0 | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-20-B-NB | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-20-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-20-V-B1.0 | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-20-V-B6.0 | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-G-20-V-NB | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-GA-03-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-GA-10-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-N-10-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-N-10-B-NB | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-N-10-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-N-20-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-N-20-B-NB | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-N-20-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-Q-10-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-S-100-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-S-100-B-NB | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-S-100-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-S-200-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-S-200-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-S-25-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-S-25-B-B6.0 | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-S-25-B-NB | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-S-25-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-S-50-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-S-50-B-B6.0 | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-S-50-B-NB | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-S-50-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| HF6887 | Fleetguard | 34.2 | 10 | 10 µm at β75(c); 11 µm at β200(c) per ISO 16889 | 30 | housing | — | inline |
| HF6888 | Fleetguard | 34.2 | 17 | 17 µm at β75(c) per ISO 16889 | 30 | housing | — | inline |
| R3.0815-56K1 | ARGO-HYTOS | 34.2 | 10 | — | 10 | housing | — | inline |
| R3.0815-58K1 | ARGO-HYTOS | 34.2 | 16 | — | 10 | housing | — | inline |
| RHR160G03B0/AB1 | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR160G03B0/ESD | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR160G03B1/ESD | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR160G03B3/AB1 | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR160G03B6/AB1 | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR160G03B6/ESD | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR160G03B/ESD | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR160G03V0/AB1 | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR160G03V1/ESD | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR160G03V3/AB1 | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR160G03V6/AB1 | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR160G03V6/ESD | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR160G03V/ESD | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR160G05B0/AB1 | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR160G05B0/ESD | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR160G05B1/ESD | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR160G05B3/AB1 | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR160G05B6/AB1 | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR160G05B6/ESD | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR160G05B/ESD | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR160G05V0/AB1 | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR160G05V1/ESD | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR160G05V3/AB1 | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR160G05V6/AB1 | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR160G05V6/ESD | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR160G05V/ESD | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR160G10B0/AB1 | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR160G10B0/ESD | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR160G10B1/ESD | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR160G10B3/AB1 | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR160G10B6/AB1 | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR160G10B6/ESD | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR160G10B/ESD | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR160G10V0/AB1 | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR160G10V1/ESD | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR160G10V3/AB1 | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR160G10V6/AB1 | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR160G10V6/ESD | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR160G10V/ESD | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR160G20B0/AB1 | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR160G20B0/ESD | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR160G20B1/ESD | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR160G20B3/AB1 | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR160G20B6/AB1 | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR160G20B6/ESD | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR160G20B/ESD | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR160G20V0/AB1 | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR160G20V1/ESD | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR160G20V3/AB1 | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR160G20V6/AB1 | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR160G20V6/ESD | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR160G20V/ESD | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR160M10B3/AB1 | Filtrec | 34.2 | 15 | β15(c)≥1000 | — | housing | — | inline |
| RHR160N03B3/AB1 | Filtrec | 34.2 | 3 | β3(c)≥2 | — | housing | — | inline |
| RHR160N05B3/AB1 | Filtrec | 34.2 | — | — | — | housing | — | inline |
| RHR160N10B0/AB1 | Filtrec | 34.2 | 10 | β10(c)≥2 | — | housing | — | inline |
| RHR160N10B3/AB1 | Filtrec | 34.2 | 10 | β10(c)≥2 | — | housing | — | inline |
| RHR160N10V3/AB1 | Filtrec | 34.2 | 10 | β10(c)≥2 | — | housing | — | inline |
| RHR160N20B0/AB1 | Filtrec | 34.2 | 25 | β25(c)≥2 | — | housing | — | inline |
| RHR160N20B3/AB1 | Filtrec | 34.2 | 25 | β25(c)≥2 | — | housing | — | inline |
| RHR160S100B0/AB1 | Filtrec | 34.2 | 100 | — | — | housing | — | inline |
| RHR160S100B3/AB1 | Filtrec | 34.2 | 100 | — | — | housing | — | inline |
| RHR160S150B3/AB1 | Filtrec | 34.2 | 150 | — | — | housing | — | inline |
| RHR160S25B0/AB1 | Filtrec | 34.2 | 25 | — | — | housing | — | inline |
| RHR160S25B3/AB1 | Filtrec | 34.2 | 25 | — | — | housing | — | inline |
| RHR160S25B6/AB1 | Filtrec | 34.2 | 25 | — | — | housing | — | inline |
| RHR160S25V3/AB1 | Filtrec | 34.2 | 25 | — | — | housing | — | inline |
| RHR160S80B3/AB1 | Filtrec | 34.2 | 80 | — | — | housing | — | inline |
Substitution verification checklist
- Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
- End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
- Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
- Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
- Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.
Frequently asked questions
Are all 74×144 mm filter elements interchangeable?
They share the same physical envelope — 74 mm OD and 144 mm length (2.91×5.67 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 122 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 74×144 mm in inches?
74×144 mm converts to approximately 2.91×5.67 in.
Browse all 74 mm OD elements or open the dimensions finder.
Request quote & availability
First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.