Envelope interchange · 2.76×12.01 in
70×305 mm filter elements
50 elements from 1 brand(s) share this envelope: 70 mm outside diameter and 305 mm overall length (2.76×12.01 in).
Dimensional interchange — verify before substituting. These cartridges fit the
same bowl space; they are not guaranteed drop-in equivalents. Compare grade,
end caps, seals, collapse rating and bypass configuration for the specific duty.
| Model | Brand | ID (mm) | Micron | β rating | Collapse (bar) | Bypass | Seal | Type |
|---|---|---|---|---|---|---|---|---|
| 01.E 320.10P.16.E.P.- | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.10P.16.S.P.- | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.10VG.16.E.P.- | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.10VG.16.S.P.- | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.25VG.16.E.P.- | Eaton / Internormen | — | 20 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.25VG.16.S.P.- | Eaton / Internormen | — | 20 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.25G.16.E.P.- | Eaton / Internormen | — | 25 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.25G.16.S.P.- | Eaton / Internormen | — | 25 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.40G.16.S.P.- | Eaton / Internormen | — | 40 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.6VG.16.E.P.- | Eaton / Internormen | — | 7 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.40G.16.E.P.- | Eaton / Internormen | — | 40 | — | 16 | housing | Nitrile (Buna-N) | inline |
| 01.E 320.16VG.16.S.P.- | Eaton / Internormen | — | 15 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.25G.16.S.P.VA | Eaton / Internormen | — | 25 | — | 16 | housing | Nitrile (Buna-N) | inline |
| 01.E 320.80G.16.E.P.- | Eaton / Internormen | — | 80 | — | 16 | housing | Nitrile (Buna-N) | inline |
| 01.E 320.6VG.16.S.P.- | Eaton / Internormen | — | 7 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.3VG.16.E.P.- | Eaton / Internormen | — | 5 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.16VG.16.E.P.- | Eaton / Internormen | — | 15 | — | 16 | housing | Nitrile (Buna-N) | inline |
| 01.E 320.80G.16.S.P.- | Eaton / Internormen | — | 80 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.130G.16.S.P.- | Eaton / Internormen | — | 130 | — | 16 | housing | Nitrile (Buna-N) | inline |
| 01.E 320.25VG.16.S.V.- | Eaton / Internormen | — | 20 | — | 16 | housing | Fluorocarbon (Viton) | inline |
| 01.E 320.10VG.16.S.V.- | Eaton / Internormen | — | 10 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 320.10VG.16.S1.P | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.16VG.16.S1.P | Eaton / Internormen | — | 15 | — | 16 | housing | Nitrile (Buna-N) | inline |
| 01.E 320.6VG.16.S1.P.- | Eaton / Internormen | — | 7 | — | 16 | housing | Nitrile (Buna-N) | inline |
| 01.E 320.3VG.16.S.P.- | Eaton / Internormen | — | 5 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.10VG.16.S.P.IS06 | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.10VG.16.S.V.IS06 | Eaton / Internormen | — | 10 | — | 16 | housing | Fluorocarbon (Viton) | inline |
| 01.E 320.16VG.16.S.V.- | Eaton / Internormen | — | 15 | — | 16 | housing | Fluorocarbon (Viton) | inline |
| 01.E 320.10VG.16.S1.P.D | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.10VG.16.S.P.D | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.10VG.16.E.P.IS06 | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.10VG.16.S1.V | Eaton / Internormen | — | 10 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 320.25VG.16.S1.V.- | Eaton / Internormen | — | 20 | — | 16 | housing | Fluorocarbon (Viton) | inline |
| 01.E 320.25VG.16.S1.P.- | Eaton / Internormen | — | 20 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.25VG.16.S.V.IS06 | Eaton / Internormen | — | 20 | — | 16 | housing | Fluorocarbon (Viton) | inline |
| 01.E 320.1VG.16.S.P.- | Eaton / Internormen | — | 4 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.25VG.16.S.P.D.- | Eaton / Internormen | — | 20 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.6VG.16.S.P.IS06 | Eaton / Internormen | — | 7 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.3VG.16.S.V.- | Eaton / Internormen | — | 5 | — | 16 | housing | Fluorocarbon (Viton) | inline |
| 01.E 320.10VG.16.S.P.VA | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | inline |
| 01.E 320.3VG.16.S1.P.- | Eaton / Internormen | — | 5 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.10VG.16.E.V.- | Eaton / Internormen | — | 10 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 320.25VG.16.S.P.IS06 | Eaton / Internormen | — | 20 | — | 16 | housing | Nitrile (Buna-N) | inline |
| 01.E 320.25G.16.E.V.VA | Eaton / Internormen | — | 25 | — | 16 | housing | Fluorocarbon (Viton) | inline |
| 01.E 320.3VG.16.S1.P.IS06 | Eaton / Internormen | — | 5 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.25G.16.S1.P.- | Eaton / Internormen | — | 25 | — | 16 | housing | Nitrile (Buna-N) | return |
| 01.E 320.10VG.16.E.V.IS08 | Eaton / Internormen | — | 10 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 320.10VG.16.S.V.VA | Eaton / Internormen | — | 10 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 320.10P.16.E.V.IS08 | Eaton / Internormen | — | 10 | — | 16 | housing | Fluorocarbon (Viton) | return |
| 01.E 320.10VG.16.S.P.IS27 | Eaton / Internormen | — | 10 | — | 16 | housing | Nitrile (Buna-N) | return |
Substitution verification checklist
- Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
- End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
- Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
- Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
- Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.
Frequently asked questions
Are all 70×305 mm filter elements interchangeable?
They share the same physical envelope — 70 mm OD and 305 mm length (2.76×12.01 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 50 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 70×305 mm in inches?
70×305 mm converts to approximately 2.76×12.01 in.
Browse all 70 mm OD elements or open the dimensions finder.
Request quote & availability
First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.