Envelope interchange · 2.36×8.03 in

60×204 mm filter elements

26 elements from 1 brand(s) share this envelope: 60 mm outside diameter and 204 mm overall length (2.36×8.03 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
DLD100B10B2 Filtrec 32.5 10 — — housing — inline
DLD100B10V2 Filtrec 32.5 10 — — housing — inline
DLD100B25B2 Filtrec 32.5 25 — — housing — inline
DLD100B25V2 Filtrec 32.5 25 — — housing — inline
DLD100B40B2 Filtrec 32.5 40 — — housing — inline
DLD100B40V2 Filtrec 32.5 40 — — housing — inline
DLD100B80B2 Filtrec 32.5 80 — — housing — inline
DLD100B80V2 Filtrec 32.5 80 — — housing — inline
DLD100E03B2 Filtrec 32.5 5 β5(c)≥1000 — housing — inline
DLD100E03V2 Filtrec 32.5 5 β5(c)≥1000 — housing — inline
DLD100E05B2 Filtrec 32.5 7 β7(c)≥1000 — housing — inline
DLD100E05V2 Filtrec 32.5 7 β7(c)≥1000 — housing — inline
DLD100E10B2 Filtrec 32.5 12 β12(c)≥1000 — housing — inline
DLD100E10V2 Filtrec 32.5 12 β12(c)≥1000 — housing — inline
DLD100E15B2 Filtrec 32.5 17 β17(c)≥1000 — housing — inline
DLD100E15V2 Filtrec 32.5 17 β17(c)≥1000 — housing — inline
DLD100E20B2 Filtrec 32.5 22 β22(c)≥1000 — housing — inline
DLD100E20V2 Filtrec 32.5 22 β22(c)≥1000 — housing — inline
RHR240A03B3/AB1 Filtrec 34.5 — — — housing — inline
RHR240A05B3/AB1 Filtrec 34.5 — — — housing — inline
RHR240A10B0/AB1 Filtrec 34.5 — — — housing — inline
RHR240A10B3/AB1 Filtrec 34.5 — — — housing — inline
RHR240A10V3/AB1 Filtrec 34.5 — — — housing — inline
RHR240A20B3/AB1 Filtrec 34.5 — — — housing — inline
RHR240B100B3/AB1 Filtrec 34.5 100 — — housing — inline
RHR240B25B3/AB1 Filtrec 34.5 25 — — housing — inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 60×204 mm filter elements interchangeable?
They share the same physical envelope — 60 mm OD and 204 mm length (2.36×8.03 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 26 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 60×204 mm in inches?
60×204 mm converts to approximately 2.36×8.03 in.

Browse all 60 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.