Envelope interchange · 2.36×5.67 in
60×144 mm filter elements
73 elements from 4 brand(s) share this envelope: 60 mm outside diameter and 144 mm overall length (2.36×5.67 in).
Dimensional interchange — verify before substituting. These cartridges fit the
same bowl space; they are not guaranteed drop-in equivalents. Compare grade,
end caps, seals, collapse rating and bypass configuration for the specific duty.
| Model | Brand | ID (mm) | Micron | β rating | Collapse (bar) | Bypass | Seal | Type |
|---|---|---|---|---|---|---|---|---|
| HD819/2 | MANN-FILTER | 20 | — | — | — | housing | — | inline |
| RE-045-A-03-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-A-03-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-A-03-V-NB | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-A-05-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-A-05-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-A-10-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-A-10-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-A-10-V-B6.0 | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-A-10-V-NB | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-A-20-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-A-20-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-B-100-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-B-100-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-B-200-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-B-25-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-B-25-B-B6.0 | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-B-25-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-B-50-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-B-50-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-D-03-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-D-05-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-D-10-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-D-10-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-D-20-B | STAUFF | 34.2 | — | — | — | housing | — | inline |
| RE-045-D-20-V | STAUFF | 34.2 | — | — | — | housing | — | inline |
| R3.0615-53K1 | ARGO-HYTOS | 34 | 5 | — | 10 | housing | — | inline |
| R3.0615-56K1 | ARGO-HYTOS | 34 | 10 | — | 10 | housing | — | inline |
| R3.0615-58K1 | ARGO-HYTOS | 34 | 16 | — | 10 | housing | — | inline |
| RHR75G03B | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR75G03B/2 | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR75G03B/5 | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR75G03V | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR75G03V/2 | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR75G03V/5 | Filtrec | 34.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RHR75G05B | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR75G05B/2 | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR75G05B/5 | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR75G05V | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR75G05V/2 | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR75G05V/5 | Filtrec | 34.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RHR75G10B | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR75G10B/2 | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR75G10B/5 | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR75G10V/2 | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR75G10V/5 | Filtrec | 34.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RHR75G20B | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR75G20B/2 | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR75G20B/5 | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR75G20V | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR75G20V/2 | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR75G20V/5 | Filtrec | 34.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RHR75M10B | Filtrec | 34.2 | 15 | β15(c)≥1000 | — | housing | — | inline |
| RHR75M10B/2 | Filtrec | 34.2 | 15 | β15(c)≥1000 | — | housing | — | inline |
| RHR75M10B/ESD | Filtrec | 34.2 | 15 | β15(c)≥1000 | — | housing | — | inline |
| RHR75M10V | Filtrec | 34.2 | 15 | β15(c)≥1000 | — | housing | — | inline |
| RHR75N10B | Filtrec | 34.2 | 10 | β10(c)≥2 | — | housing | — | inline |
| RHR75S25B | Filtrec | 34.2 | 25 | — | — | housing | — | inline |
| RHR75S25V | Filtrec | 34.2 | 25 | — | — | housing | — | inline |
| RHR75S50B | Filtrec | 34.2 | 50 | — | — | housing | — | inline |
| RHR75S50V | Filtrec | 34.2 | 50 | — | — | housing | — | inline |
| SHS160P10B000 | Filtrec | 34.2 | — | — | — | housing | — | inline |
| SHS160P10B025 | Filtrec | 34.2 | — | — | — | housing | — | inline |
| SHS160P10V000 | Filtrec | 34.2 | — | — | — | housing | — | inline |
| SHS160P10V025 | Filtrec | 34.2 | — | — | — | housing | — | inline |
| SHS160T125B000 | Filtrec | 34.2 | 125 | — | — | housing | — | inline |
| SHS160T125B025 | Filtrec | 34.2 | 125 | — | — | housing | — | inline |
| SHS160T125V000 | Filtrec | 34.2 | 125 | — | — | housing | — | inline |
| SHS160T125V025 | Filtrec | 34.2 | 125 | — | — | housing | — | inline |
| SHS160T60B000 | Filtrec | 34.2 | 60 | — | — | housing | — | inline |
| SHS160T60B025 | Filtrec | 34.2 | 60 | — | — | housing | — | inline |
| SHS160T60V000 | Filtrec | 34.2 | 60 | — | — | housing | — | inline |
| SHS160T60V025 | Filtrec | 34.2 | 60 | — | — | housing | — | inline |
Substitution verification checklist
- Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
- End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
- Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
- Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
- Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.
Frequently asked questions
Are all 60×144 mm filter elements interchangeable?
They share the same physical envelope — 60 mm OD and 144 mm length (2.36×5.67 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 73 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 60×144 mm in inches?
60×144 mm converts to approximately 2.36×5.67 in.
Browse all 60 mm OD elements or open the dimensions finder.
Request quote & availability
First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.