Envelope interchange · 2.24×4.65 in

57×118 mm filter elements

10 elements from 2 brand(s) share this envelope: 57 mm outside diameter and 118 mm overall length (2.24×4.65 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
HF35258 Fleetguard 25.5 17 17 µm at β75(c) per ISO 16889 25 housing — inline
DHD55H03B Filtrec 25.2 5 β5(c)≥1000 — housing — inline
DHD55H03B/ESD Filtrec 25.2 5 β5(c)≥1000 — housing — inline
DHD55H05B Filtrec 25.2 7 β7(c)≥1000 — housing — inline
DHD55H05B/ESD Filtrec 25.2 7 β7(c)≥1000 — housing — inline
DHD55H10B Filtrec 25.2 12 β12(c)≥1000 — housing — inline
DHD55H10B/ESD Filtrec 25.2 12 β12(c)≥1000 — housing — inline
DHD55H10V Filtrec 25.2 12 β12(c)≥1000 — housing — inline
DHD55H20B Filtrec 25.2 22 β22(c)≥1000 — housing — inline
DHD55H20B/ESD Filtrec 25.2 22 β22(c)≥1000 — housing — inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 57×118 mm filter elements interchangeable?
They share the same physical envelope — 57 mm OD and 118 mm length (2.24×4.65 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 10 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 57×118 mm in inches?
57×118 mm converts to approximately 2.24×4.65 in.

Browse all 57 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.