Envelope interchange · 2.05×3.94 in

52×100 mm filter elements

78 elements from 2 brand(s) share this envelope: 52 mm outside diameter and 100 mm overall length (2.05×3.94 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
HF40014 Fleetguard 22 10 10 µm at β75(c); 11 µm at β200(c) per ISO 16889 40 housing — inline
RHR60G03B0/AB1 Filtrec 22.2 5 β5(c)≥1000 — housing — inline
RHR60G03B0/ESD Filtrec 22.2 5 β5(c)≥1000 — housing — inline
RHR60G03B1/ESD Filtrec 22.2 5 β5(c)≥1000 — housing — inline
RHR60G03B3/AB1 Filtrec 22.2 5 β5(c)≥1000 — housing — inline
RHR60G03B3/ESD Filtrec 22.2 5 β5(c)≥1000 — housing — inline
RHR60G03B6/AB1 Filtrec 22.2 5 β5(c)≥1000 — housing — inline
RHR60G03B6/ESD Filtrec 22.2 5 β5(c)≥1000 — housing — inline
RHR60G03V0/AB1 Filtrec 22.2 5 β5(c)≥1000 — housing — inline
RHR60G03V0/ESD Filtrec 22.2 5 β5(c)≥1000 — housing — inline
RHR60G03V1/ESD Filtrec 22.2 5 β5(c)≥1000 — housing — inline
RHR60G03V3/AB1 Filtrec 22.2 5 β5(c)≥1000 — housing — inline
RHR60G03V3/ESD Filtrec 22.2 5 β5(c)≥1000 — housing — inline
RHR60G03V6/AB1 Filtrec 22.2 5 β5(c)≥1000 — housing — inline
RHR60G03V6/ESD Filtrec 22.2 5 β5(c)≥1000 — housing — inline
RHR60G05B0/AB1 Filtrec 22.2 7 β7(c)≥1000 — housing — inline
RHR60G05B0/ESD Filtrec 22.2 7 β7(c)≥1000 — housing — inline
RHR60G05B1/ESD Filtrec 22.2 7 β7(c)≥1000 — housing — inline
RHR60G05B3/AB1 Filtrec 22.2 7 β7(c)≥1000 — housing — inline
RHR60G05B3/ESD Filtrec 22.2 7 β7(c)≥1000 — housing — inline
RHR60G05B6/AB1 Filtrec 22.2 7 β7(c)≥1000 — housing — inline
RHR60G05B6/ESD Filtrec 22.2 7 β7(c)≥1000 — housing — inline
RHR60G05V0/AB1 Filtrec 22.2 7 β7(c)≥1000 — housing — inline
RHR60G05V0/ESD Filtrec 22.2 7 β7(c)≥1000 — housing — inline
RHR60G05V1/ESD Filtrec 22.2 7 β7(c)≥1000 — housing — inline
RHR60G05V3/AB1 Filtrec 22.2 7 β7(c)≥1000 — housing — inline
RHR60G05V3/ESD Filtrec 22.2 7 β7(c)≥1000 — housing — inline
RHR60G05V6/AB1 Filtrec 22.2 7 β7(c)≥1000 — housing — inline
RHR60G05V6/ESD Filtrec 22.2 7 β7(c)≥1000 — housing — inline
RHR60G10B0/AB1 Filtrec 22.2 12 β12(c)≥1000 — housing — inline
RHR60G10B0/ESD Filtrec 22.2 12 β12(c)≥1000 — housing — inline
RHR60G10B1/ESD Filtrec 22.2 12 β12(c)≥1000 — housing — inline
RHR60G10B3/AB1 Filtrec 22.2 12 β12(c)≥1000 — housing — inline
RHR60G10B3/ESD Filtrec 22.2 12 β12(c)≥1000 — housing — inline
RHR60G10B6/AB1 Filtrec 22.2 12 β12(c)≥1000 — housing — inline
RHR60G10B6/ESD Filtrec 22.2 12 β12(c)≥1000 — housing — inline
RHR60G10V0/AB1 Filtrec 22.2 12 β12(c)≥1000 — housing — inline
RHR60G10V0/ESD Filtrec 22.2 12 β12(c)≥1000 — housing — inline
RHR60G10V1/ESD Filtrec 22.2 12 β12(c)≥1000 — housing — inline
RHR60G10V3/AB1 Filtrec 22.2 12 β12(c)≥1000 — housing — inline
RHR60G10V3/ESD Filtrec 22.2 12 β12(c)≥1000 — housing — inline
RHR60G10V6/AB1 Filtrec 22.2 12 β12(c)≥1000 — housing — inline
RHR60G10V6/ESD Filtrec 22.2 12 β12(c)≥1000 — housing — inline
RHR60G20B0/AB1 Filtrec 22.2 22 β22(c)≥1000 — housing — inline
RHR60G20B0/ESD Filtrec 22.2 22 β22(c)≥1000 — housing — inline
RHR60G20B1/ESD Filtrec 22.2 22 β22(c)≥1000 — housing — inline
RHR60G20B3/AB1 Filtrec 22.2 22 β22(c)≥1000 — housing — inline
RHR60G20B3/ESD Filtrec 22.2 22 β22(c)≥1000 — housing — inline
RHR60G20B6/AB1 Filtrec 22.2 22 β22(c)≥1000 — housing — inline
RHR60G20B6/ESD Filtrec 22.2 22 β22(c)≥1000 — housing — inline
RHR60G20V0/AB1 Filtrec 22.2 22 β22(c)≥1000 — housing — inline
RHR60G20V0/ESD Filtrec 22.2 22 β22(c)≥1000 — housing — inline
RHR60G20V1/ESD Filtrec 22.2 22 β22(c)≥1000 — housing — inline
RHR60G20V3/AB1 Filtrec 22.2 22 β22(c)≥1000 — housing — inline
RHR60G20V3/ESD Filtrec 22.2 22 β22(c)≥1000 — housing — inline
RHR60G20V6/AB1 Filtrec 22.2 22 β22(c)≥1000 — housing — inline
RHR60G20V6/ESD Filtrec 22.2 22 β22(c)≥1000 — housing — inline
RHR60N03B3/AB1 Filtrec 22.2 3 β3(c)≥2 — housing — inline
RHR60N05B3/AB1 Filtrec 22.2 — — — housing — inline
RHR60N10B0/AB1 Filtrec 22.2 10 β10(c)≥2 — housing — inline
RHR60N10B3/AB1 Filtrec 22.2 10 β10(c)≥2 — housing — inline
RHR60N10V3/AB1 Filtrec 22.2 10 β10(c)≥2 — housing — inline
RHR60N20B0/AB1 Filtrec 22.2 25 β25(c)≥2 — housing — inline
RHR60N20B3/AB1 Filtrec 22.2 25 β25(c)≥2 — housing — inline
RHR60S100B0/AB1 Filtrec 22.2 100 — — housing — inline
RHR60S100B3/AB1 Filtrec 22.2 — — — housing — inline
RHR60S150B0/AB1 Filtrec 22.2 150 — — housing — inline
RHR60S150B3/AB1 Filtrec 22.2 150 — — housing — inline
RHR60S25B0/AB1 Filtrec 22.2 25 — — housing — inline
RHR60S25B3/AB1 Filtrec 22.2 25 — — housing — inline
RHR60S25B6/AB1 Filtrec 22.2 25 — — housing — inline
RHR60S25V0/AB1 Filtrec 22.2 25 — — housing — inline
RHR60S25V3/AB1 Filtrec 22.2 25 — — housing — inline
RHR60S25V6/AB1 Filtrec 22.2 25 — — housing — inline
RHR60S50B0/AB1 Filtrec 22.2 50 — — housing — inline
RHR60S50B3/AB1 Filtrec 22.2 50 — — housing — inline
RHR60S50B6/AB1 Filtrec 22.2 50 — — housing — inline
RHR60S80B3/AB1 Filtrec 22.2 80 — — housing — inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 52×100 mm filter elements interchangeable?
They share the same physical envelope — 52 mm OD and 100 mm length (2.05×3.94 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 78 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 52×100 mm in inches?
52×100 mm converts to approximately 2.05×3.94 in.

Browse all 52 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.