Envelope interchange · 1.81×9.80 in

46×249 mm filter elements

10 elements from 1 brand(s) share this envelope: 46 mm outside diameter and 249 mm overall length (1.81×9.80 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
0100 DN 003 BH4HC HYDAC 22.1 3 ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000) 210 housing Nitrile (Buna-N) pressure
0100 DN 003 BN4HC HYDAC 22.1 3 ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000) 20 housing Nitrile (Buna-N) pressure
0100 DN 006 BH4HC HYDAC 22.1 6 ßx(c) ≥ 1000 210 housing Nitrile (Buna-N) pressure
0100 DN 006 BH4HC /-SFREE HYDAC 22.1 6 ßx(c) ≥ 1000 210 housing Nitrile (Buna-N) pressure
0100 DN 006 BN4HC HYDAC 22.1 6 ßx(c) ≥ 1000 20 housing Nitrile (Buna-N) pressure
0100 DN 010 BH4HC HYDAC 22.1 10 ßx(c) ≥ 1000 (HYDAC grade convention: β12(c) ≥ 1000) 210 housing Nitrile (Buna-N) pressure
0100 DN 010 BN4HC HYDAC 22.1 10 ßx(c) ≥ 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 housing Nitrile (Buna-N) pressure
0100 DN 025 BH4HC HYDAC 22.1 25 ßx(c) ≥ 1000 210 housing Nitrile (Buna-N) pressure
0100 DN 025 BN4HC HYDAC 22.1 25 ßx(c) ≥ 1000 20 housing Nitrile (Buna-N) pressure
0100 DN 025 W/HC HYDAC 22.1 25 ßx(c) ≥ 1000 20 housing Nitrile (Buna-N) pressure

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 46×249 mm filter elements interchangeable?
They share the same physical envelope — 46 mm OD and 249 mm length (1.81×9.80 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 10 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 46×249 mm in inches?
46×249 mm converts to approximately 1.81×9.80 in.

Browse all 46 mm OD elements or open the dimensions finder.