ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
HD55/4 MANN-FILTER 26 — — — housing — inline
4YZ10 Schroeder Industries 25 10 10 µm at β(c) ≥ 1000 (99.9% efficiency) 20.7 housing Nitrile (Buna-N) inline
4YZ25 Schroeder Industries 25 25 24 µm at β(c) ≥ 1000 (99.9% efficiency) 20.7 housing Nitrile (Buna-N) inline
4YZ5 Schroeder Industries 25 5 6.3 µm at β(c) ≥ 1000 (99.9% efficiency) 20.7 housing Nitrile (Buna-N) inline
4YZX10 Schroeder Industries 25 10 10 µm at β(c) ≥ 1000 (99.9% efficiency) 207 housing Nitrile (Buna-N) inline
4YZX3 Schroeder Industries 25 3 4.8 µm at β(c) ≥ 1000 (99.9% efficiency) 207 housing Nitrile (Buna-N) inline
4YZX5 Schroeder Industries 25 5 6.3 µm at β(c) ≥ 1000 (99.9% efficiency) 207 housing Nitrile (Buna-N) inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 46×114 mm filter elements interchangeable?
They share the same physical envelope — 46 mm OD and 114 mm length (1.81×4.49 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 7 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 46×114 mm in inches?
46×114 mm converts to approximately 1.81×4.49 in.

Browse all 46 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.