Envelope interchange · 1.77×9.84 in

45×250 mm filter elements

70 elements from 2 brand(s) share this envelope: 45 mm outside diameter and 250 mm overall length (1.77×9.84 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
V3.0525-06K9 ARGO-HYTOS 22 10 — 20 housing — inline
01.NL 100.25VG.HR.E.P.- Eaton / Internormen — 20 — 160 housing Nitrile (Buna-N) inline
01.NL 100.10VG.30.E.P.- Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) inline
01.NL 100.10VG.HR.E.P.- Eaton / Internormen — 10 — 160 housing Nitrile (Buna-N) inline
01.NL 100.3VG.30.E.P.- Eaton / Internormen — 5 — 30 housing Nitrile (Buna-N) inline
01.NL 100.6VG.30.E.P.- Eaton / Internormen — 7 — 30 housing Nitrile (Buna-N) inline
01.NL 100.16VG.30.E.P.- Eaton / Internormen — 15 — 30 housing Nitrile (Buna-N) inline
01.NL 100.25VG.30.E.P.- Eaton / Internormen — 20 — 30 housing Nitrile (Buna-N) inline
01.NL 100.25G.30.E.P.- Eaton / Internormen — 25 — 30 housing Nitrile (Buna-N) inline
01.NL 100.40G.30.E.P.- Eaton / Internormen — 40 — 30 housing Nitrile (Buna-N) inline
01.NL 100.80G.30.E.P.- Eaton / Internormen — 80 — 30 housing Nitrile (Buna-N) inline
01.NL 100.130G.30.E.P.- Eaton / Internormen — 130 — 30 housing Nitrile (Buna-N) inline
01.NL 100.3VG.HR.E.P.- Eaton / Internormen — 5 — 160 housing Nitrile (Buna-N) inline
01.NL 100.3VG.HR.E.V.- Eaton / Internormen — 5 — 160 housing Fluorocarbon (Viton) inline
01.NL 100.10VG.30.E.V.- Eaton / Internormen — 10 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.6VG.HR.E.P.- Eaton / Internormen — 7 — 160 housing Nitrile (Buna-N) inline
01.NL 100.16VG.HR.E.P.- Eaton / Internormen — 15 — 160 housing Nitrile (Buna-N) inline
01.NL 100.40G.30.E.V.- Eaton / Internormen — 40 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.25G.30.E.V.- Eaton / Internormen — 25 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.25VG.30.E.V.- Eaton / Internormen — 20 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.3VG.30.E.V.- Eaton / Internormen — 5 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.16VG.30.E.V.- Eaton / Internormen — 15 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.10G.30.E.P.VA Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) inline
01.NL 100.6VG.30.E.P.VA Eaton / Internormen — 7 — 30 housing Nitrile (Buna-N) inline
01.NL 100.10G.30.E.P.- Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) inline
01.NL 100.10VG.30.E.P.VA Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) inline
01.NL 100.25VG.30.E.P.VA Eaton / Internormen — 20 — 30 housing Nitrile (Buna-N) inline
01.NL 100.25VG.HR.E.V.- Eaton / Internormen — 20 — 160 housing Fluorocarbon (Viton) inline
01.NL 100.6VG.30.E.V.- Eaton / Internormen — 7 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.25G.HR.E.P.- Eaton / Internormen — 25 — 160 housing Nitrile (Buna-N) inline
01.NL 100.40G.HR.E.P.- Eaton / Internormen — 40 — 160 housing Nitrile (Buna-N) inline
01.NL 100.10VG.30.E.V.VA Eaton / Internormen — 10 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.10VG.30.S.P.- Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) inline
01.NL 100.25G.HR.E.P.VA Eaton / Internormen — 25 — 160 housing Nitrile (Buna-N) inline
01.NL 100.25G.30.E.P.VA Eaton / Internormen — 25 — 30 housing Nitrile (Buna-N) inline
01.NL 100.80G.30.E.P.VA Eaton / Internormen — 80 — 30 housing Nitrile (Buna-N) inline
01.NL 100.10P.30.E.P.- Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) inline
01.NL 100.80G.HR.E.P.- Eaton / Internormen — 80 — 160 housing Nitrile (Buna-N) inline
01.NL 100.10VG.30.E.P.IS06 Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) inline
01.NL 100.25API.30.E.P.VA Eaton / Internormen — 20 — 30 housing Nitrile (Buna-N) inline
01.NL 100.25API.30.E.P.- Eaton / Internormen — 20 — 30 housing Nitrile (Buna-N) inline
01.NL 100.10API.30.E.P.VA Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) inline
01.NL 100.130G.30.E.P.VA Eaton / Internormen — 130 — 30 housing Nitrile (Buna-N) inline
01.NL 100.10P.30.E.P.VA Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) inline
01.NL 100.10API.30.E.P.- Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) inline
01.NL 100.10G.30.E.P.- FA. A Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) inline
01.NL 100.10API.30.E.V.VA Eaton / Internormen — 10 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.10API.30.E.V.- Eaton / Internormen — 10 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.10VG.30.S1.P.- Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) inline
01.NL 100.130G.HR.E.P.- Eaton / Internormen — 130 — 160 housing Nitrile (Buna-N) inline
01.NL 100.3VG.30.E.V.VA Eaton / Internormen — 5 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.25G.30.S1.P.- Eaton / Internormen — 25 — 30 housing Nitrile (Buna-N) inline
01.NL 100.10VG.30.S1.V.VA Eaton / Internormen — 10 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.40G.30.S1.P.- Eaton / Internormen — 40 — 30 housing Nitrile (Buna-N) inline
01.NL 100.3VG.30.E.P.VA Eaton / Internormen — 5 — 30 housing Nitrile (Buna-N) inline
01.NL 100.10API.30.E.N.VA Eaton / Internormen — 10 — 30 housing Neoprene inline
01.NL 100.10VG.30.E.N.VA Eaton / Internormen — 10 — 30 housing Neoprene inline
01.NL 100.250G.30.E.P.VA Eaton / Internormen — 250 — 30 housing Nitrile (Buna-N) inline
01.NL 100.10VG.30.S1.V.- Eaton / Internormen — 10 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.10VG.HR.E.V.IS08 Eaton / Internormen — 10 — 160 housing Fluorocarbon (Viton) inline
01.NL 100.10VG.30.E.V.IS08 Eaton / Internormen — 10 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.10G.30.E.V.VA Eaton / Internormen — 10 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.10G.30.E.V.- Eaton / Internormen — 10 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.25VG.30.S.P.- Eaton / Internormen — 20 — 30 housing Nitrile (Buna-N) inline
01.NL 100.10VG.30.S.V.- Eaton / Internormen — 10 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.6VG.30.S1.P.VA Eaton / Internormen — 7 — 30 housing Nitrile (Buna-N) inline
01.NL 100.10API.30.S.P.VA Eaton / Internormen — 10 — 30 housing Nitrile (Buna-N) inline
01.NL 100.6VG.30.E.V.VA Eaton / Internormen — 7 — 30 housing Fluorocarbon (Viton) inline
01.NLM 106.40G.30.E.V.VA Eaton / Internormen — 40 — 30 housing Fluorocarbon (Viton) inline
01.NL 100.10VG.HR.E.EPDM.- Eaton / Internormen — 10 — 160 housing EPDM inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 45×250 mm filter elements interchangeable?
They share the same physical envelope — 45 mm OD and 250 mm length (1.77×9.84 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 70 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 45×250 mm in inches?
45×250 mm converts to approximately 1.77×9.84 in.

Browse all 45 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.