Envelope interchange · 1.65×7.05 in

42×179 mm filter elements

13 elements from 1 brand(s) share this envelope: 42 mm outside diameter and 179 mm overall length (1.65×7.05 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
D311C10A Filtrec 22.8 10 β10(c)≥2 — housing — inline
D311C10AV Filtrec 22.8 10 β10(c)≥2 — housing — inline
D311C25A Filtrec 22.8 25 β25(c)≥2 — housing — inline
D311C25AV Filtrec 22.8 25 β25(c)≥2 — housing — inline
D311G03A Filtrec 22.8 5 β5(c)≥1000 — housing — inline
D311G06A Filtrec 22.8 7 β7(c)≥1000 — housing — inline
D311G10A Filtrec 22.8 12 β12(c)≥1000 — housing — inline
D311G10AV Filtrec 22.8 12 β12(c)≥1000 — housing — inline
D311G25A Filtrec 22.8 22 β22(c)≥1000 — housing — inline
D311T10A Filtrec 22.8 10 — — housing — inline
D311T125A Filtrec 22.8 125 — — housing — inline
D311T25A Filtrec 22.8 25 — — housing — inline
D311T60A Filtrec 22.8 60 — — housing — inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 42×179 mm filter elements interchangeable?
They share the same physical envelope — 42 mm OD and 179 mm length (1.65×7.05 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 13 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 42×179 mm in inches?
42×179 mm converts to approximately 1.65×7.05 in.

Browse all 42 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.