Envelope interchange · 4.96×8.27 in

126×210 mm filter elements

26 elements from 3 brand(s) share this envelope: 126 mm outside diameter and 210 mm overall length (4.96×8.27 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
RA-270-E-03-B STAUFF 92 — — — housing — inline
RA-270-E-05-B STAUFF 92 — — — housing — inline
RA-270-E-10-B STAUFF 92 — — — housing — inline
RA-270-E-20-B STAUFF 92 — — — housing — inline
RA-270-L-10-B STAUFF 92 — — — housing — inline
HF6181 Fleetguard 92 57 57 µm at β75(c) per ISO 16889 8 housing — inline
HF7962 Fleetguard 92 10 10 µm at β75(c); 11 µm at β200(c) per ISO 16889 8 housing — inline
R730C10 Filtrec 92 10 β10(c)≥2 — housing — inline
R730C10P Filtrec 92 10 β10(c)≥2 — housing — inline
R730C25 Filtrec 92 25 β25(c)≥2 — housing — inline
R730G03 Filtrec 92 5 β5(c)≥1000 — housing — inline
R730G03P Filtrec 92 5 β5(c)≥1000 — housing — inline
R730G06P Filtrec 92 7 β7(c)≥1000 — housing — inline
R730G10 Filtrec 92 12 β12(c)≥1000 — housing — inline
R730G10P Filtrec 92 12 β12(c)≥1000 — housing — inline
R730G25 Filtrec 92 22 β22(c)≥1000 — housing — inline
R730G25P Filtrec 92 22 β22(c)≥1000 — housing — inline
R730T10 Filtrec 92 10 — — housing — inline
R730T100 Filtrec 92 100 — — housing — inline
R730T100P Filtrec 92 100 — — housing — inline
R730T25 Filtrec 92 25 — — housing — inline
R730T250 Filtrec 92 250 — — housing — inline
R730T60P Filtrec 92 60 — — housing — inline
R7F30C10B Filtrec 92 10 β10(c)≥2 — housing — inline
R7F30C25B Filtrec 92 25 β25(c)≥2 — housing — inline
R7F30M10B Filtrec 92 15 β15(c)≥1000 — housing — inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 126×210 mm filter elements interchangeable?
They share the same physical envelope — 126 mm OD and 210 mm length (4.96×8.27 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 26 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 126×210 mm in inches?
126×210 mm converts to approximately 4.96×8.27 in.

Browse all 126 mm OD elements or open the dimensions finder.

Request quote & availability